流路内熱伝達促進におよぼす乱流促進体形状の影響
Effect on Heat Transfer Augmentation by Some Geometric Shapes of a Turbulence Promoter in a Rectangular Duct
親川, 兼勇
新里, 隆男
馬渕, 幾夫
Oyakawa, Kenyu
Shinzato, Takao
Mabuchi, Ikuo
open access
Copyright (c) 1986 日本機械学会
Convective Heat Transfer
Heat Transfer Augmentation
Turbulence-Promoter
Karman Vortex
Reattachment
Pressure Drop
Duct Flow
This paper investigates how the local heat transfer coefficient is affected by geometric shape and the clearance "C", when turbulence promoters of various types (blockage ratio D/2H=0.22) are set in staggered arrangement in a rectangular duct in order to augment heat transfer from the wall. The distribution of local heat transfer coefficients depend son the clearance "C", which can be further differentiated by the presence or absence of the Karman vortex shedding. The degree of augmentation is also analysed, taking account of the pressure loss. It was found that the performance ratio η(the ratio of average pumping power) is larger than unity for all types, when the range of clearance "C" is smaller than 3 mm.
論文
日本機械学会
1986-02-25
jpn
journal article
VoR
http://hdl.handle.net/20.500.12000/198
http://hdl.handle.net/20.500.12000/198
https://u-ryukyu.repo.nii.ac.jp/records/2000813
03875016
AN00187441
日本機械学会論文集. B編
Transactions of the Japan Society of Mechanical Engineers. B
52
474
860
865
https://u-ryukyu.repo.nii.ac.jp/record/2000813/files/oyakawa_k06.pdf