限定空間内の衝突噴流による熱伝達
Heat Transfer for Two-Dimensional Jet Impingement on a Confined Wall in a Dead-End Duct
親川, 兼勇
瀬名波, 出
佐久川, 純
大城, 正明
新里, 隆男
Oyakawa, Kenyu
Senaha, Izuru
Sakugawa, Jun
Oshiro, Masa-aki
Shinzato, Takao
open access
Impingement jet
Convective heat transfer
Spent air
Pressure distribution
Flow visualization
The characteristics of the local heat transfer coefficient have been studied for a two-dimensional jet impinging perpendicular to a confined wall, with the spent air being collected in a duct which surrounds the jet delivery duct. From this experiment, the effects of the dimensionless distance between the jet exit and impingement wall, the ratio of the wall width to the jet width, and the Reynolds number on the local heat transfer are clarified. It is also confirmed that both the profiles of local pressure coefficients and the local heat transfer coefficients can be classified roughly into two patterns : that is, the bell-shaped and the flat profile.