{"_buckets": {"deposit": "de2e5068-5324-4dba-ba55-eb3b42ccd4a8"}, "_deposit": {"id": "2000806", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "2000806"}, "status": "published"}, "_oai": {"id": "oai:u-ryukyu.repo.nii.ac.jp:02000806", "sets": ["1642838338003", "1642838406845"]}, "author_link": [], "item_1617186331708": {"attribute_name": "Title", "attribute_value_mlt": [{"subitem_1551255647225": "\u4f4e\u6d41\u91cf\u57df\u3067\u306e\u9060\u5fc3\u7fbd\u6839\u306a\u3057\u30c7\u30a3\u30d5\u30e5\u30fc\u30b6\u5185\u306e\u6d41\u308c : \u7b2c1\u5831, \u30dc\u30ea\u30e5\u30fc\u30c8\u306a\u3057\u306e\u5834\u5408\u306e\u6d41\u308c\u306e\u53ef\u8996\u5316\u3068\u5727\u529b\u5909\u5316", "subitem_1551255648112": "ja"}, {"subitem_1551255647225": "Flows in the Vaneless Radial Diffuser Operating at Lower Flow Rates : 1st Report, Flow Visualization and Pressure Variations in the Radial Diffuser without Volute Casing", "subitem_1551255648112": "en"}]}, "item_1617186419668": {"attribute_name": "Creator", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "\u4f0a\u826f\u90e8, \u90a6\u592b", "creatorNameLang": "ja"}]}, {"creatorNames": [{"creatorName": "\u5c71\u91cc, \u6804\u662d", "creatorNameLang": "ja"}]}, {"creatorNames": [{"creatorName": "Irabu, Kunio", "creatorNameLang": "en"}]}, {"creatorNames": [{"creatorName": "Yamazato, Eisho", "creatorNameLang": "en"}]}]}, "item_1617186476635": {"attribute_name": "Access Rights", "attribute_value_mlt": [{"subitem_1522299639480": "open access", "subitem_1600958577026": "http://purl.org/coar/access_right/c_abf2"}]}, "item_1617186499011": {"attribute_name": "Rights", "attribute_value_mlt": [{"subitem_1522650717957": "ja", "subitem_1522651041219": "Copyright (c) 1991 \u65e5\u672c\u6a5f\u68b0\u5b66\u4f1a"}]}, "item_1617186609386": {"attribute_name": "Subject", "attribute_value_mlt": [{"subitem_1522299896455": "en", "subitem_1522300014469": "Other", "subitem_1523261968819": "Fluid Machinery"}, {"subitem_1522299896455": "en", "subitem_1522300014469": "Other", "subitem_1523261968819": "Radial Diffuser"}, {"subitem_1522299896455": "en", "subitem_1522300014469": "Other", "subitem_1523261968819": "Flow visualization"}, {"subitem_1522299896455": "en", "subitem_1522300014469": "Other", "subitem_1523261968819": "Rotating Stall"}, {"subitem_1522299896455": "en", "subitem_1522300014469": "Other", "subitem_1523261968819": "Internal Flow"}, {"subitem_1522299896455": "en", "subitem_1522300014469": "Other", "subitem_1523261968819": "Fluctuating Pressure"}]}, "item_1617186626617": {"attribute_name": "Description", "attribute_value_mlt": [{"subitem_description": "Experiments for water flows using flow visualization techniques and for air flows using some conventional instruments were conducted on the vaneless diffusers. The rotating stall cells were confirmed in the region of lower flow rates in the vaneless radial diffuser, and the flow characteristic parameters of existence of the rotating stall cells were attained for various space widths between the impeller open face and lower diffuser side wall. The relationships between the variations in pressure and the traveling speeds of the stall cells were also shown. The pressure distributions in the vaneless diffuser can be represented by an empirical relation for the outer range of normal operating flow rates.", "subitem_description_type": "Other"}, {"subitem_description": "\u8ad6\u6587", "subitem_description_type": "Other"}]}, "item_1617186643794": {"attribute_name": "Publisher", "attribute_value_mlt": [{"subitem_1522300295150": "ja", "subitem_1522300316516": "\u65e5\u672c\u6a5f\u68b0\u5b66\u4f1a"}]}, "item_1617186702042": {"attribute_name": "Language", "attribute_value_mlt": [{"subitem_1551255818386": "jpn"}]}, "item_1617186783814": {"attribute_name": "Identifier", "attribute_value_mlt": [{"subitem_identifier_type": "HDL", "subitem_identifier_uri": "http://hdl.handle.net/20.500.12000/232"}]}, "item_1617186920753": {"attribute_name": "Source Identifier", "attribute_value_mlt": [{"subitem_1522646500366": "ISSN", "subitem_1522646572813": "03875016"}, {"subitem_1522646500366": "NCID", "subitem_1522646572813": "AN00187441"}]}, "item_1617186941041": {"attribute_name": "Source Title", "attribute_value_mlt": [{"subitem_1522650068558": "ja", "subitem_1522650091861": "\u65e5\u672c\u6a5f\u68b0\u5b66\u4f1a\u8ad6\u6587\u96c6. B\u7de8"}, {"subitem_1522650068558": "en", "subitem_1522650091861": "Transactions of the Japan Society of Mechanical Engineers. B"}]}, "item_1617187056579": {"attribute_name": "Bibliographic Information", "attribute_value_mlt": [{"bibliographicIssueNumber": "543", "bibliographicPageEnd": "166", "bibliographicPageStart": "161", "bibliographicVolumeNumber": "57"}]}, "item_1617258105262": {"attribute_name": "Resource Type", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_1617265215918": {"attribute_name": "Version Type", "attribute_value_mlt": [{"subitem_1522305645492": "VoR", "subitem_1600292170262": "http://purl.org/coar/version/c_970fb48d4fbd8a85"}]}, "item_1617605131499": {"attribute_name": "File", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_access", "download_preview_message": "", "file_order": 0, "filename": "irabu_k02.pdf", "future_date_message": "", "is_thumbnail": false, "mimetype": "", "size": 0, "url": {"objectType": "fulltext", "url": "https://u-ryukyu.repo.nii.ac.jp/record/2000806/files/irabu_k02.pdf"}, "version_id": "5e910353-f4c4-4a63-a8ce-8aa15513cbcc"}]}, "item_title": "\u4f4e\u6d41\u91cf\u57df\u3067\u306e\u9060\u5fc3\u7fbd\u6839\u306a\u3057\u30c7\u30a3\u30d5\u30e5\u30fc\u30b6\u5185\u306e\u6d41\u308c : \u7b2c1\u5831, \u30dc\u30ea\u30e5\u30fc\u30c8\u306a\u3057\u306e\u5834\u5408\u306e\u6d41\u308c\u306e\u53ef\u8996\u5316\u3068\u5727\u529b\u5909\u5316", "item_type_id": "15", "owner": "1", "path": ["1642838338003", "1642838406845"], "permalink_uri": "http://hdl.handle.net/20.500.12000/232", "pubdate": {"attribute_name": "PubDate", "attribute_value": "2007-03-04"}, "publish_date": "2007-03-04", "publish_status": "0", "recid": "2000806", "relation": {}, "relation_version_is_last": true, "title": ["\u4f4e\u6d41\u91cf\u57df\u3067\u306e\u9060\u5fc3\u7fbd\u6839\u306a\u3057\u30c7\u30a3\u30d5\u30e5\u30fc\u30b6\u5185\u306e\u6d41\u308c : \u7b2c1\u5831, \u30dc\u30ea\u30e5\u30fc\u30c8\u306a\u3057\u306e\u5834\u5408\u306e\u6d41\u308c\u306e\u53ef\u8996\u5316\u3068\u5727\u529b\u5909\u5316"], "weko_shared_id": -1}
  1. 学術雑誌論文
  2. その他
  1. 部局別インデックス
  2. 工学部

低流量域での遠心羽根なしディフューザ内の流れ : 第1報, ボリュートなしの場合の流れの可視化と圧力変化

http://hdl.handle.net/20.500.12000/232
http://hdl.handle.net/20.500.12000/232
382c8b5f-7052-40fa-a064-de48604ebfa6
名前 / ファイル ライセンス アクション
irabu_k02.pdf irabu_k02.pdf
Item type デフォルトアイテムタイプ(フル)(1)
公開日 2007-03-04
タイトル
タイトル 低流量域での遠心羽根なしディフューザ内の流れ : 第1報, ボリュートなしの場合の流れの可視化と圧力変化
言語 ja
作成者 伊良部, 邦夫

× 伊良部, 邦夫

ja 伊良部, 邦夫

山里, 栄昭

× 山里, 栄昭

ja 山里, 栄昭

Irabu, Kunio

× Irabu, Kunio

en Irabu, Kunio

Yamazato, Eisho

× Yamazato, Eisho

en Yamazato, Eisho

アクセス権
アクセス権 open access
アクセス権URI http://purl.org/coar/access_right/c_abf2
権利情報
言語 ja
権利情報 Copyright (c) 1991 日本機械学会
主題
言語 en
主題Scheme Other
主題 Fluid Machinery
言語 en
主題Scheme Other
主題 Radial Diffuser
言語 en
主題Scheme Other
主題 Flow visualization
言語 en
主題Scheme Other
主題 Rotating Stall
言語 en
主題Scheme Other
主題 Internal Flow
言語 en
主題Scheme Other
主題 Fluctuating Pressure
内容記述
内容記述タイプ Other
内容記述 Experiments for water flows using flow visualization techniques and for air flows using some conventional instruments were conducted on the vaneless diffusers. The rotating stall cells were confirmed in the region of lower flow rates in the vaneless radial diffuser, and the flow characteristic parameters of existence of the rotating stall cells were attained for various space widths between the impeller open face and lower diffuser side wall. The relationships between the variations in pressure and the traveling speeds of the stall cells were also shown. The pressure distributions in the vaneless diffuser can be represented by an empirical relation for the outer range of normal operating flow rates.
内容記述タイプ Other
内容記述 論文
出版者
言語 ja
出版者 日本機械学会
言語
言語 jpn
資源タイプ
資源タイプ journal article
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
出版タイプ
出版タイプ VoR
出版タイプResource http://purl.org/coar/version/c_970fb48d4fbd8a85
識別子
識別子 http://hdl.handle.net/20.500.12000/232
識別子タイプ HDL
収録物識別子
収録物識別子タイプ ISSN
収録物識別子 03875016
収録物識別子タイプ NCID
収録物識別子 AN00187441
収録物名
言語 ja
収録物名 日本機械学会論文集. B編
書誌情報
巻 57, 号 543, p. 161-166