{"created":"2022-01-24T08:32:25.451995+00:00","id":2000811,"links":{},"metadata":{"_buckets":{"deposit":"1a9cc3d4-544a-4a2d-9baa-d5bfcea643f1"},"_deposit":{"id":"2000811","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"2000811"},"status":"published"},"_oai":{"id":"oai:u-ryukyu.repo.nii.ac.jp:02000811","sets":["1642838163960:1642838338003","1642838403551:1642838406845"]},"author_link":[],"item_1617186331708":{"attribute_name":"Title","attribute_value_mlt":[{"subitem_1551255647225":"平行平板流路内に千鳥状に円柱を置いた場合の壁面熱伝達","subitem_1551255648112":"ja"},{"subitem_1551255647225":"Heat Transfer in a Parallel Plate Duct with Circular Cylinders Placed Staggered","subitem_1551255648112":"en"}]},"item_1617186419668":{"attribute_name":"Creator","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"親川, 兼勇","creatorNameLang":"ja"}]},{"creatorNames":[{"creatorName":"馬渕, 幾夫","creatorNameLang":"ja"}]},{"creatorNames":[{"creatorName":"Oyakawa, Kenyu","creatorNameLang":"en"}]},{"creatorNames":[{"creatorName":"Mabuchi, Ikuo","creatorNameLang":"en"}]}]},"item_1617186476635":{"attribute_name":"Access Rights","attribute_value_mlt":[{"subitem_1522299639480":"open access","subitem_1600958577026":"http://purl.org/coar/access_right/c_abf2"}]},"item_1617186499011":{"attribute_name":"Rights","attribute_value_mlt":[{"subitem_1522650717957":"ja","subitem_1522651041219":"Copyright (c) 1982 日本機械学会"}]},"item_1617186609386":{"attribute_name":"Subject","attribute_value_mlt":[{"subitem_1522299896455":"en","subitem_1522300014469":"Other","subitem_1523261968819":"Convective Heat Transfer"},{"subitem_1522299896455":"en","subitem_1522300014469":"Other","subitem_1523261968819":"Heat Transfer Augmentation"},{"subitem_1522299896455":"en","subitem_1522300014469":"Other","subitem_1523261968819":"Turbulence Promoter"},{"subitem_1522299896455":"en","subitem_1522300014469":"Other","subitem_1523261968819":"Pressure Loss"},{"subitem_1522299896455":"en","subitem_1522300014469":"Other","subitem_1523261968819":"Parallel Plate Duct"},{"subitem_1522299896455":"en","subitem_1522300014469":"Other","subitem_1523261968819":"Karman Vortex"},{"subitem_1522299896455":"en","subitem_1522300014469":"Other","subitem_1523261968819":"Reattachment"}]},"item_1617186626617":{"attribute_name":"Description","attribute_value_mlt":[{"subitem_description":"強制対流場での伝熱促進を計るため, 平行平板流路に円柱列(ブロッケージ比0.4)を千鳥状にそう入した場合, 局所熱伝達特性に対するピッチ比Pおよび管軸中心からの円柱オフセット量Hの影響を実験的に調べた. 局所熱伝達率分布はうず放出の有無に支配される円柱後流のフローパターンに依存することを明らかにするとともに, 伝熱促進機構について考察した. また圧力損失を考慮した熱的性能比についても検討した.","subitem_description_type":"Other"},{"subitem_description":"論文","subitem_description_type":"Other"}]},"item_1617186643794":{"attribute_name":"Publisher","attribute_value_mlt":[{"subitem_1522300295150":"ja","subitem_1522300316516":"日本機械学会"}]},"item_1617186702042":{"attribute_name":"Language","attribute_value_mlt":[{"subitem_1551255818386":"jpn"}]},"item_1617186783814":{"attribute_name":"Identifier","attribute_value_mlt":[{"subitem_identifier_type":"HDL","subitem_identifier_uri":"http://hdl.handle.net/20.500.12000/199"}]},"item_1617186920753":{"attribute_name":"Source Identifier","attribute_value_mlt":[{"subitem_1522646500366":"ISSN","subitem_1522646572813":"03875016"},{"subitem_1522646500366":"NCID","subitem_1522646572813":"AN00187441"}]},"item_1617186941041":{"attribute_name":"Source Title","attribute_value_mlt":[{"subitem_1522650068558":"ja","subitem_1522650091861":"日本機械学会論文集. B編"},{"subitem_1522650068558":"en","subitem_1522650091861":"Transactions of the Japan Society of Mechanical Engineers. B"}]},"item_1617187056579":{"attribute_name":"Bibliographic Information","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"1982-08-25","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"432","bibliographicPageEnd":"1519","bibliographicPageStart":"1509","bibliographicVolumeNumber":"48"}]},"item_1617258105262":{"attribute_name":"Resource Type","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_1617265215918":{"attribute_name":"Version Type","attribute_value_mlt":[{"subitem_1522305645492":"VoR","subitem_1600292170262":"http://purl.org/coar/version/c_970fb48d4fbd8a85"}]},"item_1617605131499":{"attribute_name":"File","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_access","filename":"oyakawa_k05.pdf","mimetype":"application/pdf","url":{"objectType":"fulltext","url":"https://u-ryukyu.repo.nii.ac.jp/record/2000811/files/oyakawa_k05.pdf"},"version_id":"c6c2a30a-4cf4-4ced-8d20-d428cdb0e737"}]},"item_title":"平行平板流路内に千鳥状に円柱を置いた場合の壁面熱伝達","item_type_id":"15","owner":"1","path":["1642838338003","1642838406845"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2007-03-04"},"publish_date":"2007-03-04","publish_status":"0","recid":"2000811","relation_version_is_last":true,"title":["平行平板流路内に千鳥状に円柱を置いた場合の壁面熱伝達"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-08-03T05:25:12.831950+00:00"}