{"created":"2022-01-24T08:49:53.804677+00:00","id":2000819,"links":{},"metadata":{"_buckets":{"deposit":"38deed54-6545-4c58-995d-ba297381f674"},"_deposit":{"id":"2000819","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"2000819"},"status":"published"},"_oai":{"id":"oai:u-ryukyu.repo.nii.ac.jp:02000819","sets":["1642838163960:1642838338003","1642838403551:1642838406845"]},"author_link":[],"item_1617186331708":{"attribute_name":"Title","attribute_value_mlt":[{"subitem_1551255647225":"噴流による後ろ向きステップ下流の再付着領域の熱伝達特性の制御に関する研究 : 第1報,噴流位置および噴流速度の効果について","subitem_1551255648112":"ja"},{"subitem_1551255647225":"Studies of Heat Transfer Control by Using Jet Discharge at Reattachment Region Downstream of a Backward-Facing Step : 1st Report, Effect of Jet Locations and Jet Volocities","subitem_1551255648112":"en"}]},"item_1617186419668":{"attribute_name":"Creator","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"親川, 兼勇","creatorNameLang":"ja"}]},{"creatorNames":[{"creatorName":"小池, 徹","creatorNameLang":"ja"}]},{"creatorNames":[{"creatorName":"馬渕, 幾夫","creatorNameLang":"ja"}]},{"creatorNames":[{"creatorName":"Oyakawa, Kenyu","creatorNameLang":"en"}]},{"creatorNames":[{"creatorName":"Koike, Toru","creatorNameLang":"en"}]},{"creatorNames":[{"creatorName":"Mabuchi, Ikuo","creatorNameLang":"en"}]}]},"item_1617186476635":{"attribute_name":"Access Rights","attribute_value_mlt":[{"subitem_1522299639480":"open access","subitem_1600958577026":"http://purl.org/coar/access_right/c_abf2"}]},"item_1617186499011":{"attribute_name":"Rights","attribute_value_mlt":[{"subitem_1522650717957":"ja","subitem_1522651041219":"Copright (c) 1993 日本機械学会"}]},"item_1617186609386":{"attribute_name":"Subject","attribute_value_mlt":[{"subitem_1522299896455":"en","subitem_1522300014469":"Other","subitem_1523261968819":"Forced Convection"},{"subitem_1522299896455":"en","subitem_1522300014469":"Other","subitem_1523261968819":"Heat Transfer Enhancement"},{"subitem_1522299896455":"en","subitem_1522300014469":"Other","subitem_1523261968819":"Heat Transfer Control"},{"subitem_1522299896455":"en","subitem_1522300014469":"Other","subitem_1523261968819":"Recirculating Flow"},{"subitem_1522299896455":"en","subitem_1522300014469":"Other","subitem_1523261968819":"Reattachment Region"},{"subitem_1522299896455":"en","subitem_1522300014469":"Other","subitem_1523261968819":"Jet Flow Visualization"}]},"item_1617186626617":{"attribute_name":"Description","attribute_value_mlt":[{"subitem_description":"The local heat transfer coefficients downstream of a backward-facing step were measured at various jet locations and jet velocities by discharging a jet perpendicularly to the main flow to control the heat transfer characteristics. It was found that flow field is characterized by the formation of a circulating bubble at the rear of a jet port on the opposite wall of the step surface (i.e., the jet port side), where the bubble causes acceleration of the main flow and shortening of the reattachment point length. Furthermore, at the optimum position X_j/H=2. 1(X_j : location of jet, measured from the step)position, H : the step height), the augmentation of mean heat transfer coefficients can be as much as 1. 6 times the value without jet discharge. Thus, by using a jet it is possible to control the heat transfer effectively.","subitem_description_type":"Other"},{"subitem_description":"論文","subitem_description_type":"Other"}]},"item_1617186643794":{"attribute_name":"Publisher","attribute_value_mlt":[{"subitem_1522300295150":"ja","subitem_1522300316516":"日本機械学会"}]},"item_1617186702042":{"attribute_name":"Language","attribute_value_mlt":[{"subitem_1551255818386":"jpn"}]},"item_1617186783814":{"attribute_name":"Identifier","attribute_value_mlt":[{"subitem_identifier_type":"HDL","subitem_identifier_uri":"http://hdl.handle.net/20.500.12000/205"}]},"item_1617186920753":{"attribute_name":"Source Identifier","attribute_value_mlt":[{"subitem_1522646500366":"ISSN","subitem_1522646572813":"03875016"},{"subitem_1522646500366":"NCID","subitem_1522646572813":"AN00187441"}]},"item_1617186941041":{"attribute_name":"Source Title","attribute_value_mlt":[{"subitem_1522650068558":"ja","subitem_1522650091861":"日本機械学会論文集. B編"},{"subitem_1522650068558":"en","subitem_1522650091861":"Transactions of the Japan Society of Mechanical Engineers. B"}]},"item_1617187056579":{"attribute_name":"Bibliographic Information","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"1993-02-25","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"558","bibliographicPageEnd":"233","bibliographicPageStart":"227","bibliographicVolumeNumber":"59"}]},"item_1617258105262":{"attribute_name":"Resource Type","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_1617265215918":{"attribute_name":"Version Type","attribute_value_mlt":[{"subitem_1522305645492":"VoR","subitem_1600292170262":"http://purl.org/coar/version/c_970fb48d4fbd8a85"}]},"item_1617605131499":{"attribute_name":"File","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_access","filename":"oyakawa_k08.pdf","mimetype":"application/pdf","url":{"objectType":"fulltext","url":"https://u-ryukyu.repo.nii.ac.jp/record/2000819/files/oyakawa_k08.pdf"},"version_id":"748be5c9-a380-4223-b975-b23646673e6a"}]},"item_title":"噴流による後ろ向きステップ下流の再付着領域の熱伝達特性の制御に関する研究 : 第1報,噴流位置および噴流速度の効果について","item_type_id":"15","owner":"1","path":["1642838338003","1642838406845"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2007-03-04"},"publish_date":"2007-03-04","publish_status":"0","recid":"2000819","relation_version_is_last":true,"title":["噴流による後ろ向きステップ下流の再付着領域の熱伝達特性の制御に関する研究 : 第1報,噴流位置および噴流速度の効果について"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-08-03T05:39:26.249682+00:00"}