{"created":"2022-01-24T08:54:15.958689+00:00","id":2000821,"links":{},"metadata":{"_buckets":{"deposit":"e1f473fc-cd57-4d85-afbb-78742847e3a0"},"_deposit":{"id":"2000821","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"2000821"},"status":"published"},"_oai":{"id":"oai:u-ryukyu.repo.nii.ac.jp:02000821","sets":["1642838163960:1642838338003","1642838403551:1642838406845"]},"author_link":[],"item_1617186331708":{"attribute_name":"Title","attribute_value_mlt":[{"subitem_1551255647225":"噴流による後ろ向きステップ下流の再付着領域の熱伝達特性の制御に関する研究 : 第2報,流路拡大比を変えた場合について","subitem_1551255648112":"ja"},{"subitem_1551255647225":"Studies of Heat Transfer Control by Jet Discharge at Reattachment Region Downstream of a Backward-Facing Step : 2nd Report, for Various Expansion Ratios","subitem_1551255648112":"en"}]},"item_1617186419668":{"attribute_name":"Creator","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"親川, 兼勇","creatorNameLang":"ja"}]},{"creatorNames":[{"creatorName":"平良, 哲治","creatorNameLang":"ja"}]},{"creatorNames":[{"creatorName":"山里, 栄昭","creatorNameLang":"ja"}]},{"creatorNames":[{"creatorName":"Oyakawa, Kenyu","creatorNameLang":"en"}]},{"creatorNames":[{"creatorName":"Taira, Tetsuji","creatorNameLang":"en"}]},{"creatorNames":[{"creatorName":"Yamazato, Eisho","creatorNameLang":"en"}]}]},"item_1617186476635":{"attribute_name":"Access Rights","attribute_value_mlt":[{"subitem_1522299639480":"open access","subitem_1600958577026":"http://purl.org/coar/access_right/c_abf2"}]},"item_1617186499011":{"attribute_name":"Rights","attribute_value_mlt":[{"subitem_1522650717957":"ja","subitem_1522651041219":"Copyright (c) 1994 日本機械学会"}]},"item_1617186609386":{"attribute_name":"Subject","attribute_value_mlt":[{"subitem_1522299896455":"en","subitem_1522300014469":"Other","subitem_1523261968819":"Forced Convection"},{"subitem_1522299896455":"en","subitem_1522300014469":"Other","subitem_1523261968819":"Heat Transfer Enhancement"},{"subitem_1522299896455":"en","subitem_1522300014469":"Other","subitem_1523261968819":"Heat Transfer Control"},{"subitem_1522299896455":"en","subitem_1522300014469":"Other","subitem_1523261968819":"Recirculating Flow"},{"subitem_1522299896455":"en","subitem_1522300014469":"Other","subitem_1523261968819":"Reattachment Region"},{"subitem_1522299896455":"en","subitem_1522300014469":"Other","subitem_1523261968819":"Jet"},{"subitem_1522299896455":"en","subitem_1522300014469":"Other","subitem_1523261968819":"Expansion Ratio"},{"subitem_1522299896455":"en","subitem_1522300014469":"Other","subitem_1523261968819":"Flow Visualization"}]},"item_1617186626617":{"attribute_name":"Description","attribute_value_mlt":[{"subitem_description":"Heat transfer downstream of a backward-facing step was controlled using a jet discharged flow from a slit in the duct wall opposite the step. The local heat transfer coefficients were measured for various jet locations, jet velocities and duct expansion ratios. The reattachment region moves upstream and the heat transfer coefficients, which are maximum, increase with jet velocity. The coefficients also increase with the expansion ratio, but to a lesser extent. With appropriate change of the downstream coordinate, the many heat coefficient profiles under various conditions may be normalized to produce a single characteristic curve. The average heat transfer over the peak in each case can be expressed as a function of its maximum.","subitem_description_type":"Other"},{"subitem_description":"論文","subitem_description_type":"Other"}]},"item_1617186643794":{"attribute_name":"Publisher","attribute_value_mlt":[{"subitem_1522300295150":"ja","subitem_1522300316516":"日本機械学会"}]},"item_1617186702042":{"attribute_name":"Language","attribute_value_mlt":[{"subitem_1551255818386":"jpn"}]},"item_1617186783814":{"attribute_name":"Identifier","attribute_value_mlt":[{"subitem_identifier_type":"HDL","subitem_identifier_uri":"http://hdl.handle.net/20.500.12000/206"}]},"item_1617186920753":{"attribute_name":"Source Identifier","attribute_value_mlt":[{"subitem_1522646500366":"ISSN","subitem_1522646572813":"03875016"},{"subitem_1522646500366":"NCID","subitem_1522646572813":"AN00187441"}]},"item_1617186941041":{"attribute_name":"Source Title","attribute_value_mlt":[{"subitem_1522650068558":"ja","subitem_1522650091861":"日本機械学会論文集. B編"},{"subitem_1522650068558":"en","subitem_1522650091861":"Transactions of the Japan Society of Mechanical Engineers. B"}]},"item_1617187056579":{"attribute_name":"Bibliographic Information","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"1994-01-25","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"569","bibliographicPageEnd":"254","bibliographicPageStart":"248","bibliographicVolumeNumber":"60"}]},"item_1617258105262":{"attribute_name":"Resource Type","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_1617265215918":{"attribute_name":"Version Type","attribute_value_mlt":[{"subitem_1522305645492":"VoR","subitem_1600292170262":"http://purl.org/coar/version/c_970fb48d4fbd8a85"}]},"item_1617605131499":{"attribute_name":"File","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_access","filename":"oyakawa_k09.pdf","mimetype":"application/pdf","url":{"objectType":"fulltext","url":"https://u-ryukyu.repo.nii.ac.jp/record/2000821/files/oyakawa_k09.pdf"},"version_id":"318ae383-fd2f-4fe3-895f-22b663806f2a"}]},"item_title":"噴流による後ろ向きステップ下流の再付着領域の熱伝達特性の制御に関する研究 : 第2報,流路拡大比を変えた場合について","item_type_id":"15","owner":"1","path":["1642838338003","1642838406845"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2007-03-04"},"publish_date":"2007-03-04","publish_status":"0","recid":"2000821","relation_version_is_last":true,"title":["噴流による後ろ向きステップ下流の再付着領域の熱伝達特性の制御に関する研究 : 第2報,流路拡大比を変えた場合について"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-08-03T05:27:09.770250+00:00"}