{"created":"2022-01-25T05:55:33.464754+00:00","id":2001563,"links":{},"metadata":{"_buckets":{"deposit":"6fad2753-1058-41d6-bac3-07acbb69fe40"},"_deposit":{"id":"2001563","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"2001563"},"status":"published"},"_oai":{"id":"oai:u-ryukyu.repo.nii.ac.jp:02001563","sets":["1642837622505:1642837855274:1642837876648","1642838403551:1642838406845"]},"author_link":[],"item_1617186331708":{"attribute_name":"Title","attribute_value_mlt":[{"subitem_1551255647225":"二枚柵防風ネットの基礎杭の引抜き耐力","subitem_1551255648112":"ja"},{"subitem_1551255647225":"The Pullout Resistance of Steel Piles of Wind-proof Double Net System","subitem_1551255648112":"en"}]},"item_1617186419668":{"attribute_name":"Creator","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"天野, 輝久","creatorNameLang":"ja"}]},{"creatorNames":[{"creatorName":"福島, 弘志","creatorNameLang":"ja"}]},{"creatorNames":[{"creatorName":"仲宗根, 功士","creatorNameLang":"ja"}]},{"creatorNames":[{"creatorName":"上門, 太","creatorNameLang":"ja"}]},{"creatorNames":[{"creatorName":"具志堅, 功","creatorNameLang":"ja"}]},{"creatorNames":[{"creatorName":"Amano, Teruhisa","creatorNameLang":"en"}]},{"creatorNames":[{"creatorName":"Fukushima, Hiroshi","creatorNameLang":"en"}]},{"creatorNames":[{"creatorName":"Nakasone, Kouji","creatorNameLang":"en"}]},{"creatorNames":[{"creatorName":"Uejoh, Futoshi","creatorNameLang":"en"}]},{"creatorNames":[{"creatorName":"Gushiken, Isao","creatorNameLang":"en"}]}]},"item_1617186476635":{"attribute_name":"Access Rights","attribute_value_mlt":[{"subitem_1522299639480":"open access","subitem_1600958577026":"http://purl.org/coar/access_right/c_abf2"}]},"item_1617186609386":{"attribute_name":"Subject","attribute_value_mlt":[{"subitem_1522299896455":"en","subitem_1522300014469":"Other","subitem_1523261968819":"Pullout forces"},{"subitem_1522299896455":"en","subitem_1522300014469":"Other","subitem_1523261968819":"Friction of piles"},{"subitem_1522299896455":"en","subitem_1522300014469":"Other","subitem_1523261968819":"Wind-proof net system"}]},"item_1617186626617":{"attribute_name":"Description","attribute_value_mlt":[{"subitem_description":"The resistance to pullout forces subjected to steel piles of newly invented wind-proof double net system is tested. The pullout force and the displacement are measured for simple steel piles with different underground depth and four kinds of piles on which the various attachements are welded to increase the surface friction. The experiment is carried out at two geotechnical sites representing two typical Okinawa's clays.\\nAs the results of the experiment, the piles with fin-type attachment showed the highest pullout resistance which is well estimated by modifying the empirical friction formula.","subitem_description_type":"Other"},{"subitem_description":"紀要論文","subitem_description_type":"Other"}]},"item_1617186643794":{"attribute_name":"Publisher","attribute_value_mlt":[{"subitem_1522300295150":"ja","subitem_1522300316516":"琉球大学工学部"}]},"item_1617186702042":{"attribute_name":"Language","attribute_value_mlt":[{"subitem_1551255818386":"jpn"}]},"item_1617186783814":{"attribute_name":"Identifier","attribute_value_mlt":[{"subitem_identifier_type":"HDL","subitem_identifier_uri":"http://hdl.handle.net/20.500.12000/1430"}]},"item_1617186920753":{"attribute_name":"Source Identifier","attribute_value_mlt":[{"subitem_1522646500366":"ISSN","subitem_1522646572813":"0389-102X"},{"subitem_1522646500366":"NCID","subitem_1522646572813":"AN0025048X"}]},"item_1617186941041":{"attribute_name":"Source Title","attribute_value_mlt":[{"subitem_1522650068558":"ja","subitem_1522650091861":"琉球大学工学部紀要"}]},"item_1617187056579":{"attribute_name":"Bibliographic Information","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2000-09","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"60","bibliographicPageEnd":"20","bibliographicPageStart":"15"}]},"item_1617258105262":{"attribute_name":"Resource Type","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_1617265215918":{"attribute_name":"Version Type","attribute_value_mlt":[{"subitem_1522305645492":"VoR","subitem_1600292170262":"http://purl.org/coar/version/c_970fb48d4fbd8a85"}]},"item_1617605131499":{"attribute_name":"File","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_access","filename":"No60p15.pdf","mimetype":"application/pdf","url":{"objectType":"fulltext","url":"https://u-ryukyu.repo.nii.ac.jp/record/2001563/files/No60p15.pdf"},"version_id":"4f3615ae-5d91-4501-b98a-2c739f2350e8"}]},"item_title":"二枚柵防風ネットの基礎杭の引抜き耐力","item_type_id":"15","owner":"1","path":["1642837876648","1642838406845"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2007-08-23"},"publish_date":"2007-08-23","publish_status":"0","recid":"2001563","relation_version_is_last":true,"title":["二枚柵防風ネットの基礎杭の引抜き耐力"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2022-10-31T00:50:54.621661+00:00"}