{"created":"2022-01-27T02:01:41.046902+00:00","id":2001632,"links":{},"metadata":{"_buckets":{"deposit":"18b58448-6903-41dd-8bf5-eb80297a6a6b"},"_deposit":{"id":"2001632","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"2001632"},"status":"published"},"_oai":{"id":"oai:u-ryukyu.repo.nii.ac.jp:02001632","sets":["1642837622505:1642837855274:1642837875288","1642838403551:1642838406845"]},"author_link":[],"item_1617186331708":{"attribute_name":"Title","attribute_value_mlt":[{"subitem_1551255647225":"通気層を持つ戸建住宅の熱環境に関する実測調査","subitem_1551255648112":"ja"},{"subitem_1551255647225":"Full Scale Measurement of Thermal Performance of a Single-Unit House with Double Skins","subitem_1551255648112":"en"}]},"item_1617186419668":{"attribute_name":"Creator","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"新川, 亮樹","creatorNameLang":"ja"}]},{"creatorNames":[{"creatorName":"堤, 純一郎","creatorNameLang":"ja"}]},{"creatorNames":[{"creatorName":"Arakawa, Ryoki","creatorNameLang":"en"}]},{"creatorNames":[{"creatorName":"Tsutsumi, Jun-ichiro","creatorNameLang":"en"}]}]},"item_1617186476635":{"attribute_name":"Access Rights","attribute_value_mlt":[{"subitem_1522299639480":"open access","subitem_1600958577026":"http://purl.org/coar/access_right/c_abf2"}]},"item_1617186609386":{"attribute_name":"Subject","attribute_value_mlt":[{"subitem_1522299896455":"en","subitem_1522300014469":"Other","subitem_1523261968819":"Double skin walls"},{"subitem_1522299896455":"en","subitem_1522300014469":"Other","subitem_1523261968819":"Stable heat transmission"},{"subitem_1522299896455":"en","subitem_1522300014469":"Other","subitem_1523261968819":"Simulation"}]},"item_1617186626617":{"attribute_name":"Description","attribute_value_mlt":[{"subitem_description":"Passive cooling system is used to improve the thermal performance of a house. The thermal performance of a passive cooling house with double skins is an object of this measurement.\\nWe measured the temperature distribution around the double skin walls and heat flow rate to clarify the thermal characteristics of the house. Moreover, ventilation rate without openings was measured by C0_2 concentration method to get the air tightness of the house. Then, we made a simulation program for the prediction of air temperature based on the stable heat transmission to compare with the measured data.","subitem_description_type":"Other"},{"subitem_description":"紀要論文","subitem_description_type":"Other"}]},"item_1617186643794":{"attribute_name":"Publisher","attribute_value_mlt":[{"subitem_1522300295150":"ja","subitem_1522300316516":"琉球大学工学部"}]},"item_1617186702042":{"attribute_name":"Language","attribute_value_mlt":[{"subitem_1551255818386":"jpn"}]},"item_1617186783814":{"attribute_name":"Identifier","attribute_value_mlt":[{"subitem_identifier_type":"HDL","subitem_identifier_uri":"http://hdl.handle.net/20.500.12000/1484"}]},"item_1617186920753":{"attribute_name":"Source Identifier","attribute_value_mlt":[{"subitem_1522646500366":"ISSN","subitem_1522646572813":"0389-102X"},{"subitem_1522646500366":"NCID","subitem_1522646572813":"AN0025048X"}]},"item_1617186941041":{"attribute_name":"Source Title","attribute_value_mlt":[{"subitem_1522650068558":"ja","subitem_1522650091861":"琉球大学工学部紀要"}]},"item_1617187056579":{"attribute_name":"Bibliographic Information","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"1999-03","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"57","bibliographicPageEnd":"24","bibliographicPageStart":"19"}]},"item_1617258105262":{"attribute_name":"Resource Type","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_1617265215918":{"attribute_name":"Version Type","attribute_value_mlt":[{"subitem_1522305645492":"VoR","subitem_1600292170262":"http://purl.org/coar/version/c_970fb48d4fbd8a85"}]},"item_1617605131499":{"attribute_name":"File","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_access","filename":"No57p19.pdf","mimetype":"application/pdf","url":{"objectType":"fulltext","url":"https://u-ryukyu.repo.nii.ac.jp/record/2001632/files/No57p19.pdf"},"version_id":"dc4e43a2-590b-4d3b-9599-f6893449c5ff"}]},"item_title":"通気層を持つ戸建住宅の熱環境に関する実測調査","item_type_id":"15","owner":"1","path":["1642837875288","1642838406845"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2007-08-23"},"publish_date":"2007-08-23","publish_status":"0","recid":"2001632","relation_version_is_last":true,"title":["通気層を持つ戸建住宅の熱環境に関する実測調査"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2022-10-31T00:52:33.630282+00:00"}