{"created":"2022-01-27T02:13:11.316253+00:00","id":2001995,"links":{},"metadata":{"_buckets":{"deposit":"eb5d0696-bcfe-4c69-be6d-80649c9a6918"},"_deposit":{"id":"2001995","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"2001995"},"status":"published"},"_oai":{"id":"oai:u-ryukyu.repo.nii.ac.jp:02001995","sets":["1642837622505:1642837855274:1642837872220","1642838403551:1642838406845"]},"author_link":[],"item_1617186331708":{"attribute_name":"Title","attribute_value_mlt":[{"subitem_1551255647225":"Attenuation Correction for X-ray Emission Computed Tomography of Laser-Prouduced Plasma","subitem_1551255648112":"en"}]},"item_1617186419668":{"attribute_name":"Creator","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Chen, Yen-Wei","creatorNameLang":"en"}]},{"creatorNames":[{"creatorName":"Nakao, Zensho","creatorNameLang":"en"}]},{"creatorNames":[{"creatorName":"Tamura, Shinichi","creatorNameLang":"en"}]},{"creatorNames":[{"creatorName":"陳, 延偉","creatorNameLang":"ja"}]},{"creatorNames":[{"creatorName":"仲尾, 善勝","creatorNameLang":"ja"}]}]},"item_1617186476635":{"attribute_name":"Access Rights","attribute_value_mlt":[{"subitem_1522299639480":"open access","subitem_1600958577026":"http://purl.org/coar/access_right/c_abf2"}]},"item_1617186609386":{"attribute_name":"Subject","attribute_value_mlt":[{"subitem_1522299896455":"en","subitem_1522300014469":"Other","subitem_1523261968819":"Emission computed tomography (ECT)"},{"subitem_1522299896455":"en","subitem_1522300014469":"Other","subitem_1523261968819":"Attenuation correction"},{"subitem_1522299896455":"en","subitem_1522300014469":"Other","subitem_1523261968819":"Projection"},{"subitem_1522299896455":"en","subitem_1522300014469":"Other","subitem_1523261968819":"Reconstruction"},{"subitem_1522299896455":"en","subitem_1522300014469":"Other","subitem_1523261968819":"Algebraic reconstruction technique(ART)"}]},"item_1617186626617":{"attribute_name":"Description","attribute_value_mlt":[{"subitem_description":"An attenuation correction method was proposed for laser-produced plasma emission computed tomography (ECT), which is based on relation of attenuation coefficient and emission coefficient in plasma. Simulation results show that the reconstructed images are dramatically improved in comparison to reconstructions without attenuation correction.","subitem_description_type":"Other"},{"subitem_description":"紀要論文","subitem_description_type":"Other"}]},"item_1617186643794":{"attribute_name":"Publisher","attribute_value_mlt":[{"subitem_1522300295150":"ja","subitem_1522300316516":"琉球大学工学部"}]},"item_1617186702042":{"attribute_name":"Language","attribute_value_mlt":[{"subitem_1551255818386":"eng"}]},"item_1617186783814":{"attribute_name":"Identifier","attribute_value_mlt":[{"subitem_identifier_type":"HDL","subitem_identifier_uri":"http://hdl.handle.net/20.500.12000/1977"}]},"item_1617186920753":{"attribute_name":"Source Identifier","attribute_value_mlt":[{"subitem_1522646500366":"ISSN","subitem_1522646572813":"0389-102X"},{"subitem_1522646500366":"NCID","subitem_1522646572813":"AN0025048X"}]},"item_1617186941041":{"attribute_name":"Source Title","attribute_value_mlt":[{"subitem_1522650068558":"ja","subitem_1522650091861":"琉球大学工学部紀要"}]},"item_1617187056579":{"attribute_name":"Bibliographic Information","attribute_value_mlt":[{"bibliographicIssueNumber":"50","bibliographicPageEnd":"160","bibliographicPageStart":"155"}]},"item_1617258105262":{"attribute_name":"Resource Type","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_1617265215918":{"attribute_name":"Version Type","attribute_value_mlt":[{"subitem_1522305645492":"VoR","subitem_1600292170262":"http://purl.org/coar/version/c_970fb48d4fbd8a85"}]},"item_1617605131499":{"attribute_name":"File","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_access","filename":"No50p155.pdf","mimetype":"application/pdf","url":{"objectType":"fulltext","url":"https://u-ryukyu.repo.nii.ac.jp/record/2001995/files/No50p155.pdf"},"version_id":"6cdbe51c-843b-45be-8ab7-0638b9d566b3"}]},"item_title":"Attenuation Correction for X-ray Emission Computed Tomography of Laser-Prouduced Plasma","item_type_id":"15","owner":"1","path":["1642837872220","1642838406845"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2007-09-16"},"publish_date":"2007-09-16","publish_status":"0","recid":"2001995","relation_version_is_last":true,"title":["Attenuation Correction for X-ray Emission Computed Tomography of Laser-Prouduced Plasma"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2022-02-14T21:20:22.531998+00:00"}