{"created":"2022-01-27T07:37:30.711209+00:00","id":2003557,"links":{},"metadata":{"_buckets":{"deposit":"072ce228-98c0-49df-8200-f9e398e05f8b"},"_deposit":{"id":"2003557","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"2003557"},"status":"published"},"_oai":{"id":"oai:u-ryukyu.repo.nii.ac.jp:02003557","sets":["1642838163960:1642838338003","1642838403551:1642838406845"]},"author_link":[],"item_1617186331708":{"attribute_name":"Title","attribute_value_mlt":[{"subitem_1551255647225":"An adaptive dead-time compensation strategy for voltage source inverter fed motor drives","subitem_1551255648112":"en"}]},"item_1617186419668":{"attribute_name":"Creator","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Urasaki, Naomitsu","creatorNameLang":"en"}]},{"creatorNames":[{"creatorName":"Senjyu, Tomonobu","creatorNameLang":"en"}]},{"creatorNames":[{"creatorName":"Uezato, Katsumi","creatorNameLang":"en"}]},{"creatorNames":[{"creatorName":"Funabashi, Toshihisa","creatorNameLang":"en"}]},{"creatorNames":[{"creatorName":"浦崎, 直光","creatorNameLang":"ja"}]},{"creatorNames":[{"creatorName":"千住, 智信","creatorNameLang":"ja"}]},{"creatorNames":[{"creatorName":"上里, 勝實","creatorNameLang":"ja"}]}]},"item_1617186476635":{"attribute_name":"Access Rights","attribute_value_mlt":[{"subitem_1522299639480":"open access","subitem_1600958577026":"http://purl.org/coar/access_right/c_abf2"}]},"item_1617186499011":{"attribute_name":"Rights","attribute_value_mlt":[{"subitem_1522650717957":"en","subitem_1522651041219":"(C)2005 IEEE. Personal use of this material is permitted. However, permission to reprint/republish this material for advertising or promotional purposes or for creating new collective works for resale or redistribution to servers or lists, or to reuse any copyrighted component of this work in other works must be obtained from the IEEE."}]},"item_1617186609386":{"attribute_name":"Subject","attribute_value_mlt":[{"subitem_1522299896455":"en","subitem_1522300014469":"Other","subitem_1523261968819":"current vector"},{"subitem_1522299896455":"en","subitem_1522300014469":"Other","subitem_1523261968819":"dead-time"},{"subitem_1522299896455":"en","subitem_1522300014469":"Other","subitem_1523261968819":"disturbance observer"},{"subitem_1522299896455":"en","subitem_1522300014469":"Other","subitem_1523261968819":"permanent magnet synchronous motor (PMSM)"},{"subitem_1522299896455":"en","subitem_1522300014469":"Other","subitem_1523261968819":"voltage source inverter (VSI)"}]},"item_1617186626617":{"attribute_name":"Description","attribute_value_mlt":[{"subitem_description":"This paper presents an adaptive dead-time compensation strategy to obtain fundamental phase voltage for inverter fed vector controlled permanent magnet synchronous motor drives. The amplitude of phase dead-time compensation voltage (DTCV) to compensate disturbance voltage due to undesirable characteristics of inverter, such as dead-time, turn-on/off time of switching devices, and on-voltages of switching devices and diodes is adaptively determined according to a dead-time compensation time (DTCT). DTCT is identified on-line with using a /spl delta/-axis disturbance voltage in the current reference frame that is synchronized with current vector. The /spl delta/-axis disturbance voltage is estimated by a disturbance observer. The accuracy of identified DTCT is experimentally confirmed by calculating the mean absolute percentage error (MAPE) between a calculated active power and a measured one. MAPE for adaptive DTCT is almost within 5% at any operating point.","subitem_description_type":"Other"},{"subitem_description":"論文","subitem_description_type":"Other"}]},"item_1617186643794":{"attribute_name":"Publisher","attribute_value_mlt":[{"subitem_1522300295150":"en","subitem_1522300316516":"IEEE Institute of Electrical and Electronics"}]},"item_1617186702042":{"attribute_name":"Language","attribute_value_mlt":[{"subitem_1551255818386":"eng"}]},"item_1617186783814":{"attribute_name":"Identifier","attribute_value_mlt":[{"subitem_identifier_type":"HDL","subitem_identifier_uri":"http://hdl.handle.net/20.500.12000/4630"}]},"item_1617186920753":{"attribute_name":"Source Identifier","attribute_value_mlt":[{"subitem_1522646500366":"ISSN","subitem_1522646572813":"0885-8993"},{"subitem_1522646500366":"NCID","subitem_1522646572813":"AA10670151"}]},"item_1617186941041":{"attribute_name":"Source Title","attribute_value_mlt":[{"subitem_1522650068558":"en","subitem_1522650091861":"IEEE Transactions on Power Electronics"}]},"item_1617187056579":{"attribute_name":"Bibliographic Information","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2005-09","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"5","bibliographicPageEnd":"1160","bibliographicPageStart":"1150","bibliographicVolumeNumber":"20"}]},"item_1617258105262":{"attribute_name":"Resource Type","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_1617265215918":{"attribute_name":"Version Type","attribute_value_mlt":[{"subitem_1522305645492":"VoR","subitem_1600292170262":"http://purl.org/coar/version/c_970fb48d4fbd8a85"}]},"item_1617353299429":{"attribute_name":"Relation","attribute_value_mlt":[{"subitem_1522306287251":{"subitem_1522306382014":"URI","subitem_1522306436033":"http://ieeexplore.ieee.org/xpl/RecentIssue.jsp?punumber=63"}}]},"item_1617605131499":{"attribute_name":"File","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_access","filename":"IEEE_PE_v20n5_1150.pdf","mimetype":"application/pdf","url":{"objectType":"fulltext","url":"https://u-ryukyu.repo.nii.ac.jp/record/2003557/files/IEEE_PE_v20n5_1150.pdf"},"version_id":"126f2fb5-5a96-4b9d-8834-eb7fbd50b9a1"}]},"item_title":"An adaptive dead-time compensation strategy for voltage source inverter fed motor drives","item_type_id":"15","owner":"1","path":["1642838338003","1642838406845"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2008-02-18"},"publish_date":"2008-02-18","publish_status":"0","recid":"2003557","relation_version_is_last":true,"title":["An adaptive dead-time compensation strategy for voltage source inverter fed motor drives"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-08-03T05:24:57.042974+00:00"}