@article{oai:u-ryukyu.repo.nii.ac.jp:02003801, author = {親川, 兼勇 and 瀬名波, 出 and 佐久川, 純 and 大城, 正明 and 新里, 隆男 and Oyakawa, Kenyu and Senaha, Izuru and Sakugawa, Jun and Oshiro, Masa-aki and Shinzato, Takao}, issue = {46}, journal = {琉球大学工学部紀要}, month = {Sep}, note = {The characteristics of the local heat transfer coefficient have been studied for a two-dimensional jet impinging perpendicular to a confined wall, with the spent air being collected in a duct which surrounds the jet delivery duct. From this experiment, the effects of the dimensionless distance between the jet exit and impingement wall, the ratio of the wall width to the jet width, and the Reynolds number on the local heat transfer are clarified. It is also confirmed that both the profiles of local pressure coefficients and the local heat transfer coefficients can be classified roughly into two patterns : that is, the bell-shaped and the flat profile., 紀要論文}, pages = {37--43}, title = {限定空間内の衝突噴流による熱伝達}, year = {1993} }