{"_buckets": {"deposit": "81e7e38e-e2e5-4edd-9ea2-58623a1c0b83"}, "_deposit": {"id": "2003820", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "2003820"}, "status": "published"}, "_oai": {"id": "oai:u-ryukyu.repo.nii.ac.jp:02003820", "sets": ["1642837866387", "1642838406845"]}, "author_link": [], "item_1617186331708": {"attribute_name": "Title", "attribute_value_mlt": [{"subitem_1551255647225": "デュアルレートサンプリング適応形負荷周波数制御", "subitem_1551255648112": "ja"}, {"subitem_1551255647225": "A Load Frequency Self-Tuning Regulator Based on Dual-Rate Sampling", "subitem_1551255648112": "en"}]}, "item_1617186419668": {"attribute_name": "Creator", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "山下, 勝己", "creatorNameLang": "ja"}]}, {"creatorNames": [{"creatorName": "平安, 充", "creatorNameLang": "ja"}]}, {"creatorNames": [{"creatorName": "宮城, 隼夫", "creatorNameLang": "ja"}]}, {"creatorNames": [{"creatorName": "Yamashita, Katsumi", "creatorNameLang": "en"}]}, {"creatorNames": [{"creatorName": "Hirayasu, Mituru", "creatorNameLang": "en"}]}, {"creatorNames": [{"creatorName": "Miyagi, Hayao", "creatorNameLang": "en"}]}]}, "item_1617186476635": {"attribute_name": "Access Rights", "attribute_value_mlt": [{"subitem_1522299639480": "open access", "subitem_1600958577026": "http://purl.org/coar/access_right/c_abf2"}]}, "item_1617186609386": {"attribute_name": "Subject", "attribute_value_mlt": [{"subitem_1522299896455": "en", "subitem_1522300014469": "Other", "subitem_1523261968819": "Self-Tuning Regulator"}, {"subitem_1522299896455": "en", "subitem_1522300014469": "Other", "subitem_1523261968819": "Load Frequency Control"}, {"subitem_1522299896455": "en", "subitem_1522300014469": "Other", "subitem_1523261968819": "Dual- Rate Sampling"}, {"subitem_1522299896455": "en", "subitem_1522300014469": "Other", "subitem_1523261968819": "Power Systems"}]}, "item_1617186626617": {"attribute_name": "Description", "attribute_value_mlt": [{"subitem_description": "This paper presents a new method of designing a load frequency self-tuning regulator for power system based on dual-rate sampling. The method is applied to a two-area power system provided with reheat type turbines and then the control effect of the proposed regulator is compared with that of standard sampling self-tuning regulator using digital simulations.", "subitem_description_type": "Other"}, {"subitem_description": "紀要論文", "subitem_description_type": "Other"}]}, "item_1617186643794": {"attribute_name": "Publisher", "attribute_value_mlt": [{"subitem_1522300295150": "ja", "subitem_1522300316516": "琉球大学工学部"}]}, "item_1617186702042": {"attribute_name": "Language", "attribute_value_mlt": [{"subitem_1551255818386": "jpn"}]}, "item_1617186783814": {"attribute_name": "Identifier", "attribute_value_mlt": [{"subitem_identifier_type": "HDL", "subitem_identifier_uri": "http://hdl.handle.net/20.500.12000/5493"}]}, "item_1617186920753": {"attribute_name": "Source Identifier", "attribute_value_mlt": [{"subitem_1522646500366": "ISSN", "subitem_1522646572813": "0389-102X"}, {"subitem_1522646500366": "NCID", "subitem_1522646572813": "AN0025048X"}]}, "item_1617186941041": {"attribute_name": "Source Title", "attribute_value_mlt": [{"subitem_1522650068558": "ja", "subitem_1522650091861": "琉球大学工学部紀要"}]}, "item_1617187056579": {"attribute_name": "Bibliographic Information", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "1991-09", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "42", "bibliographicPageEnd": "90", "bibliographicPageStart": "85"}]}, "item_1617258105262": {"attribute_name": "Resource Type", "attribute_value_mlt": [{"resourcetype": "departmental bulletin paper", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_1617265215918": {"attribute_name": "Version Type", "attribute_value_mlt": [{"subitem_1522305645492": "VoR", "subitem_1600292170262": "http://purl.org/coar/version/c_970fb48d4fbd8a85"}]}, "item_1617605131499": {"attribute_name": "File", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_access", "download_preview_message": "", "file_order": 0, "filename": "No42p85.pdf", "future_date_message": "", "is_thumbnail": false, "mimetype": "", "size": 0, "url": {"objectType": "fulltext", "url": "https://u-ryukyu.repo.nii.ac.jp/record/2003820/files/No42p85.pdf"}, "version_id": "4134c072-aac3-4fa0-9f5c-a9faf8eddcb8"}]}, "item_title": "デュアルレートサンプリング適応形負荷周波数制御", "item_type_id": "15", "owner": "1", "path": ["1642837866387", "1642838406845"], "permalink_uri": "http://hdl.handle.net/20.500.12000/5493", "pubdate": {"attribute_name": "PubDate", "attribute_value": "2008-04-01"}, "publish_date": "2008-04-01", "publish_status": "0", "recid": "2003820", "relation": {}, "relation_version_is_last": true, "title": ["デュアルレートサンプリング適応形負荷周波数制御"], "weko_shared_id": -1}
http://hdl.handle.net/20.500.12000/5493
http://hdl.handle.net/20.500.12000/5493