{"created":"2022-01-27T07:46:32.658464+00:00","id":2003838,"links":{},"metadata":{"_buckets":{"deposit":"68e0c968-17bb-4628-9348-9be3f7517f6e"},"_deposit":{"id":"2003838","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"2003838"},"status":"published"},"_oai":{"id":"oai:u-ryukyu.repo.nii.ac.jp:02003838","sets":["1642837622505:1642837855274:1642837863204","1642838403551:1642838406845"]},"author_link":[],"item_1617186331708":{"attribute_name":"Title","attribute_value_mlt":[{"subitem_1551255647225":"Decentralised LQI-Type Load-frequency control with controlling delay of one sampling time for interconnected power systems","subitem_1551255648112":"en"}]},"item_1617186419668":{"attribute_name":"Creator","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Yamashita, Katsumi","creatorNameLang":"en"}]},{"creatorNames":[{"creatorName":"Miyagi, Hayao","creatorNameLang":"en"}]},{"creatorNames":[{"creatorName":"山下, 勝己","creatorNameLang":"ja"}]},{"creatorNames":[{"creatorName":"宮城, 隼夫","creatorNameLang":"ja"}]}]},"item_1617186476635":{"attribute_name":"Access Rights","attribute_value_mlt":[{"subitem_1522299639480":"open access","subitem_1600958577026":"http://purl.org/coar/access_right/c_abf2"}]},"item_1617186626617":{"attribute_name":"Description","attribute_value_mlt":[{"subitem_description":"This paper presents a new method of designing decentralised discrete-type load-frequency regulator with controlling delay of one sampling time for interconnected power systems. In this method, the interconnected multi-area electric energy system is decomposed into several subsystems, each of which is controlled separately by using a local feedback only. An especially attractive feature of the proposed control scheme is that it considers the time delay due to the computation time of the control law and the transmission time of the system data over the telemeter links to the controlling plant. An additional feature is that the construction of the regulator is based on the conventional tie-line bias control. The proposed control scheme is illustrated by digital simulation of a 2-area system provided with reheat steam turbines. The results show that this discrete-type regulator can act satisfactorily for improving dynamic responses of the load-frequency control.","subitem_description_type":"Other"},{"subitem_description":"紀要論文","subitem_description_type":"Other"}]},"item_1617186643794":{"attribute_name":"Publisher","attribute_value_mlt":[{"subitem_1522300295150":"ja","subitem_1522300316516":"琉球大学工学部"}]},"item_1617186702042":{"attribute_name":"Language","attribute_value_mlt":[{"subitem_1551255818386":"eng"}]},"item_1617186783814":{"attribute_name":"Identifier","attribute_value_mlt":[{"subitem_identifier_type":"HDL","subitem_identifier_uri":"http://hdl.handle.net/20.500.12000/5572"}]},"item_1617186920753":{"attribute_name":"Source Identifier","attribute_value_mlt":[{"subitem_1522646500366":"ISSN","subitem_1522646572813":"0389-102X"},{"subitem_1522646500366":"NCID","subitem_1522646572813":"AN0025048X"}]},"item_1617186941041":{"attribute_name":"Source Title","attribute_value_mlt":[{"subitem_1522650068558":"ja","subitem_1522650091861":"琉球大学工学部紀要"}]},"item_1617187056579":{"attribute_name":"Bibliographic Information","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"1988-03","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"35","bibliographicPageEnd":"78","bibliographicPageStart":"69"}]},"item_1617258105262":{"attribute_name":"Resource Type","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_1617265215918":{"attribute_name":"Version Type","attribute_value_mlt":[{"subitem_1522305645492":"VoR","subitem_1600292170262":"http://purl.org/coar/version/c_970fb48d4fbd8a85"}]},"item_1617605131499":{"attribute_name":"File","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_access","filename":"No35p69.pdf","mimetype":"application/pdf","url":{"objectType":"fulltext","url":"https://u-ryukyu.repo.nii.ac.jp/record/2003838/files/No35p69.pdf"},"version_id":"914f7cdf-afdc-42b5-81b9-84e6125c7fc9"}]},"item_title":"Decentralised LQI-Type Load-frequency control with controlling delay of one sampling time for interconnected power systems","item_type_id":"15","owner":"1","path":["1642837863204","1642838406845"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2008-04-02"},"publish_date":"2008-04-02","publish_status":"0","recid":"2003838","relation_version_is_last":true,"title":["Decentralised LQI-Type Load-frequency control with controlling delay of one sampling time for interconnected power systems"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2022-10-31T01:45:17.249553+00:00"}