アイテム

{"_buckets": {"deposit": "9e65995e-0216-4e0e-aca3-7d81a6af448d"}, "_deposit": {"id": "2003842", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "2003842"}, "status": "published"}, "_oai": {"id": "oai:u-ryukyu.repo.nii.ac.jp:02003842", "sets": ["1642837861937", "1642838406845"]}, "author_link": [], "item_1617186331708": {"attribute_name": "Title", "attribute_value_mlt": [{"subitem_1551255647225": "\u591a\u5730\u57df\u96fb\u529b\u7cfb\u7d71\u3092\u5bfe\u8c61\u3068\u3057\u305f1\u30b5\u30f3\u30d7\u30eb\u306e\u5236\u5fa1\u9045\u308c\u3092\u3082\u3064LQI\u5f62\u8ca0\u8377\u5468\u6ce2\u6570\u5236\u5fa1", "subitem_1551255648112": "ja"}, {"subitem_1551255647225": "LQI-Type Load-Frequency Control Having One Time Controlling Delay for Multi-Area Electric Energy Systems", "subitem_1551255648112": "en"}]}, "item_1617186419668": {"attribute_name": "Creator", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "\u5c71\u4e0b, \u52dd\u5df1", "creatorNameLang": "ja"}]}, {"creatorNames": [{"creatorName": "\u5bae\u57ce, \u96bc\u592b", "creatorNameLang": "ja"}]}, {"creatorNames": [{"creatorName": "Yamashita, Katsumi", "creatorNameLang": "en"}]}, {"creatorNames": [{"creatorName": "Miyagi, Hayao", "creatorNameLang": "en"}]}]}, "item_1617186476635": {"attribute_name": "Access Rights", "attribute_value_mlt": [{"subitem_1522299639480": "open access", "subitem_1600958577026": "http://purl.org/coar/access_right/c_abf2"}]}, "item_1617186609386": {"attribute_name": "Subject", "attribute_value_mlt": [{"subitem_1522299896455": "en", "subitem_1522300014469": "Other", "subitem_1523261968819": "Control Systems"}, {"subitem_1522299896455": "en", "subitem_1522300014469": "Other", "subitem_1523261968819": "Optimal Control"}, {"subitem_1522299896455": "en", "subitem_1522300014469": "Other", "subitem_1523261968819": "Power Systems"}]}, "item_1617186626617": {"attribute_name": "Description", "attribute_value_mlt": [{"subitem_description": "This paper presents a new method of designing discrete-type load-frequency regulator for interconnected power systems. An especially attractive feature of the proposed control scheme is that it requires as inputs signals accumulative quantities of area control error. An additional feature is that it considers the time delay due to the computation time of the control law and the transmission time of the system data over the telemeter links to the controlling plant. The realization of such a regulator may be easy and of low cost because of its simple construction.\\nIn this paper, we apply the above method to 3\uff5e5 area systems provided with nonreheat type turbines. The results show that the proposed discrete-type regulator can act satisfactorily for improving dynamic responses of the load-frequency control.", "subitem_description_type": "Other"}, {"subitem_description": "\u7d00\u8981\u8ad6\u6587", "subitem_description_type": "Other"}]}, "item_1617186643794": {"attribute_name": "Publisher", "attribute_value_mlt": [{"subitem_1522300295150": "ja", "subitem_1522300316516": "\u7409\u7403\u5927\u5b66\u5de5\u5b66\u90e8"}]}, "item_1617186702042": {"attribute_name": "Language", "attribute_value_mlt": [{"subitem_1551255818386": "jpn"}]}, "item_1617186783814": {"attribute_name": "Identifier", "attribute_value_mlt": [{"subitem_identifier_type": "HDL", "subitem_identifier_uri": "http://hdl.handle.net/20.500.12000/5576"}]}, "item_1617186920753": {"attribute_name": "Source Identifier", "attribute_value_mlt": [{"subitem_1522646500366": "ISSN", "subitem_1522646572813": "0389-102X"}, {"subitem_1522646500366": "NCID", "subitem_1522646572813": "AN0025048X"}]}, "item_1617186941041": {"attribute_name": "Source Title", "attribute_value_mlt": [{"subitem_1522650068558": "ja", "subitem_1522650091861": "\u7409\u7403\u5927\u5b66\u5de5\u5b66\u90e8\u7d00\u8981"}]}, "item_1617187056579": {"attribute_name": "Bibliographic Information", "attribute_value_mlt": [{"bibliographicIssueNumber": "32", "bibliographicPageEnd": "141", "bibliographicPageStart": "135"}]}, "item_1617258105262": {"attribute_name": "Resource Type", "attribute_value_mlt": [{"resourcetype": "departmental bulletin paper", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_1617265215918": {"attribute_name": "Version Type", "attribute_value_mlt": [{"subitem_1522305645492": "VoR", "subitem_1600292170262": "http://purl.org/coar/version/c_970fb48d4fbd8a85"}]}, "item_1617605131499": {"attribute_name": "File", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_access", "download_preview_message": "", "file_order": 0, "filename": "No32p135.pdf", "future_date_message": "", "is_thumbnail": false, "mimetype": "", "size": 0, "url": {"objectType": "fulltext", "url": "https://u-ryukyu.repo.nii.ac.jp/record/2003842/files/No32p135.pdf"}, "version_id": "b5cc95ab-c82d-4d61-aa9d-f37cba452b60"}]}, "item_title": "\u591a\u5730\u57df\u96fb\u529b\u7cfb\u7d71\u3092\u5bfe\u8c61\u3068\u3057\u305f1\u30b5\u30f3\u30d7\u30eb\u306e\u5236\u5fa1\u9045\u308c\u3092\u3082\u3064LQI\u5f62\u8ca0\u8377\u5468\u6ce2\u6570\u5236\u5fa1", "item_type_id": "15", "owner": "1", "path": ["1642837861937", "1642838406845"], "permalink_uri": "http://hdl.handle.net/20.500.12000/5576", "pubdate": {"attribute_name": "PubDate", "attribute_value": "2008-04-02"}, "publish_date": "2008-04-02", "publish_status": "0", "recid": "2003842", "relation": {}, "relation_version_is_last": true, "title": ["\u591a\u5730\u57df\u96fb\u529b\u7cfb\u7d71\u3092\u5bfe\u8c61\u3068\u3057\u305f1\u30b5\u30f3\u30d7\u30eb\u306e\u5236\u5fa1\u9045\u308c\u3092\u3082\u3064LQI\u5f62\u8ca0\u8377\u5468\u6ce2\u6570\u5236\u5fa1"], "weko_shared_id": -1}
  1. 紀要論文
  2. 琉球大学工学部紀要
  3. 32号
  1. 部局別インデックス
  2. 工学部

多地域電力系統を対象とした1サンプルの制御遅れをもつLQI形負荷周波数制御

http://hdl.handle.net/20.500.12000/5576
http://hdl.handle.net/20.500.12000/5576
3f31485c-2644-40aa-adae-2fa3cfc16e47
名前 / ファイル ライセンス アクション
No32p135.pdf No32p135.pdf
Item type デフォルトアイテムタイプ(フル)(1)
公開日 2008-04-02
タイトル
タイトル 多地域電力系統を対象とした1サンプルの制御遅れをもつLQI形負荷周波数制御
言語 ja
作成者 山下, 勝己

× 山下, 勝己

ja 山下, 勝己

宮城, 隼夫

× 宮城, 隼夫

ja 宮城, 隼夫

Yamashita, Katsumi

× Yamashita, Katsumi

en Yamashita, Katsumi

Miyagi, Hayao

× Miyagi, Hayao

en Miyagi, Hayao

アクセス権
アクセス権 open access
アクセス権URI http://purl.org/coar/access_right/c_abf2
主題
言語 en
主題Scheme Other
主題 Control Systems
言語 en
主題Scheme Other
主題 Optimal Control
言語 en
主題Scheme Other
主題 Power Systems
内容記述
内容記述タイプ Other
内容記述 This paper presents a new method of designing discrete-type load-frequency regulator for interconnected power systems. An especially attractive feature of the proposed control scheme is that it requires as inputs signals accumulative quantities of area control error. An additional feature is that it considers the time delay due to the computation time of the control law and the transmission time of the system data over the telemeter links to the controlling plant. The realization of such a regulator may be easy and of low cost because of its simple construction.\nIn this paper, we apply the above method to 3~5 area systems provided with nonreheat type turbines. The results show that the proposed discrete-type regulator can act satisfactorily for improving dynamic responses of the load-frequency control.
内容記述タイプ Other
内容記述 紀要論文
出版者
言語 ja
出版者 琉球大学工学部
言語
言語 jpn
資源タイプ
資源タイプ departmental bulletin paper
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
出版タイプ
出版タイプ VoR
出版タイプResource http://purl.org/coar/version/c_970fb48d4fbd8a85
識別子
識別子 http://hdl.handle.net/20.500.12000/5576
識別子タイプ HDL
収録物識別子
収録物識別子タイプ ISSN
収録物識別子 0389-102X
収録物識別子タイプ NCID
収録物識別子 AN0025048X
収録物名
言語 ja
収録物名 琉球大学工学部紀要
書誌情報
号 32, p. 135-141
戻る
0
views
See details
Views

Versions

Ver.1 2022-01-27 07:46:44.864251
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON

確認


Powered by WEKO3


Powered by WEKO3