{"created":"2022-01-27T07:46:41.743513+00:00","id":2003842,"links":{},"metadata":{"_buckets":{"deposit":"9e65995e-0216-4e0e-aca3-7d81a6af448d"},"_deposit":{"id":"2003842","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"2003842"},"status":"published"},"_oai":{"id":"oai:u-ryukyu.repo.nii.ac.jp:02003842","sets":["1642837622505:1642837855274:1642837861937","1642838403551:1642838406845"]},"author_link":[],"item_1617186331708":{"attribute_name":"Title","attribute_value_mlt":[{"subitem_1551255647225":"多地域電力系統を対象とした1サンプルの制御遅れをもつLQI形負荷周波数制御","subitem_1551255648112":"ja"},{"subitem_1551255647225":"LQI-Type Load-Frequency Control Having One Time Controlling Delay for Multi-Area Electric Energy Systems","subitem_1551255648112":"en"}]},"item_1617186419668":{"attribute_name":"Creator","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"山下, 勝己","creatorNameLang":"ja"}]},{"creatorNames":[{"creatorName":"宮城, 隼夫","creatorNameLang":"ja"}]},{"creatorNames":[{"creatorName":"Yamashita, Katsumi","creatorNameLang":"en"}]},{"creatorNames":[{"creatorName":"Miyagi, Hayao","creatorNameLang":"en"}]}]},"item_1617186476635":{"attribute_name":"Access Rights","attribute_value_mlt":[{"subitem_1522299639480":"open access","subitem_1600958577026":"http://purl.org/coar/access_right/c_abf2"}]},"item_1617186609386":{"attribute_name":"Subject","attribute_value_mlt":[{"subitem_1522299896455":"en","subitem_1522300014469":"Other","subitem_1523261968819":"Control Systems"},{"subitem_1522299896455":"en","subitem_1522300014469":"Other","subitem_1523261968819":"Optimal Control"},{"subitem_1522299896455":"en","subitem_1522300014469":"Other","subitem_1523261968819":"Power Systems"}]},"item_1617186626617":{"attribute_name":"Description","attribute_value_mlt":[{"subitem_description":"This paper presents a new method of designing discrete-type load-frequency regulator for interconnected power systems. An especially attractive feature of the proposed control scheme is that it requires as inputs signals accumulative quantities of area control error. An additional feature is that it considers the time delay due to the computation time of the control law and the transmission time of the system data over the telemeter links to the controlling plant. The realization of such a regulator may be easy and of low cost because of its simple construction.\\nIn this paper, we apply the above method to 3~5 area systems provided with nonreheat type turbines. The results show that the proposed discrete-type regulator can act satisfactorily for improving dynamic responses of the load-frequency control.","subitem_description_type":"Other"},{"subitem_description":"紀要論文","subitem_description_type":"Other"}]},"item_1617186643794":{"attribute_name":"Publisher","attribute_value_mlt":[{"subitem_1522300295150":"ja","subitem_1522300316516":"琉球大学工学部"}]},"item_1617186702042":{"attribute_name":"Language","attribute_value_mlt":[{"subitem_1551255818386":"jpn"}]},"item_1617186783814":{"attribute_name":"Identifier","attribute_value_mlt":[{"subitem_identifier_type":"HDL","subitem_identifier_uri":"http://hdl.handle.net/20.500.12000/5576"}]},"item_1617186920753":{"attribute_name":"Source Identifier","attribute_value_mlt":[{"subitem_1522646500366":"ISSN","subitem_1522646572813":"0389-102X"},{"subitem_1522646500366":"NCID","subitem_1522646572813":"AN0025048X"}]},"item_1617186941041":{"attribute_name":"Source Title","attribute_value_mlt":[{"subitem_1522650068558":"ja","subitem_1522650091861":"琉球大学工学部紀要"}]},"item_1617187056579":{"attribute_name":"Bibliographic Information","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"1986-10","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"32","bibliographicPageEnd":"141","bibliographicPageStart":"135"}]},"item_1617258105262":{"attribute_name":"Resource Type","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_1617265215918":{"attribute_name":"Version Type","attribute_value_mlt":[{"subitem_1522305645492":"VoR","subitem_1600292170262":"http://purl.org/coar/version/c_970fb48d4fbd8a85"}]},"item_1617605131499":{"attribute_name":"File","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_access","filename":"No32p135.pdf","mimetype":"application/pdf","url":{"objectType":"fulltext","url":"https://u-ryukyu.repo.nii.ac.jp/record/2003842/files/No32p135.pdf"},"version_id":"b5cc95ab-c82d-4d61-aa9d-f37cba452b60"}]},"item_title":"多地域電力系統を対象とした1サンプルの制御遅れをもつLQI形負荷周波数制御","item_type_id":"15","owner":"1","path":["1642837861937","1642838406845"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2008-04-02"},"publish_date":"2008-04-02","publish_status":"0","recid":"2003842","relation_version_is_last":true,"title":["多地域電力系統を対象とした1サンプルの制御遅れをもつLQI形負荷周波数制御"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2022-10-31T01:45:23.168494+00:00"}