{"_buckets": {"deposit": "bc83ef5d-e478-4783-ab83-69e9c59a067b"}, "_deposit": {"id": "2005592", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "2005592"}, "status": "published"}, "_oai": {"id": "oai:u-ryukyu.repo.nii.ac.jp:02005592", "sets": ["1642837872220", "1642838406845"]}, "author_link": [], "item_1617186331708": {"attribute_name": "Title", "attribute_value_mlt": [{"subitem_1551255647225": "長方形流路内の伝熱特性に関する研究 (アスペクト比の影響)", "subitem_1551255648112": "ja"}, {"subitem_1551255647225": "Characteristics of Heat Transfer in Rectangular Ducts (Effects of aspect ratio)", "subitem_1551255648112": "en"}]}, "item_1617186419668": {"attribute_name": "Creator", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "澤田, 亜希子", "creatorNameLang": "ja"}]}, {"creatorNames": [{"creatorName": "親川, 兼勇", "creatorNameLang": "ja"}]}, {"creatorNames": [{"creatorName": "屋我, 実", "creatorNameLang": "ja"}]}, {"creatorNames": [{"creatorName": "瀬名波, 出", "creatorNameLang": "ja"}]}, {"creatorNames": [{"creatorName": "Sawada, Akiko", "creatorNameLang": "en"}]}, {"creatorNames": [{"creatorName": "Oyakawa, Kenyu", "creatorNameLang": "en"}]}, {"creatorNames": [{"creatorName": "Yaga, Minoru", "creatorNameLang": "en"}]}, {"creatorNames": [{"creatorName": "Senaha, Izuru", "creatorNameLang": "en"}]}]}, "item_1617186476635": {"attribute_name": "Access Rights", "attribute_value_mlt": [{"subitem_1522299639480": "open access", "subitem_1600958577026": "http://purl.org/coar/access_right/c_abf2"}]}, "item_1617186609386": {"attribute_name": "Subject", "attribute_value_mlt": [{"subitem_1522299896455": "en", "subitem_1522300014469": "Other", "subitem_1523261968819": "Forced convection"}, {"subitem_1522299896455": "en", "subitem_1522300014469": "Other", "subitem_1523261968819": "Heat transfer"}, {"subitem_1522299896455": "en", "subitem_1522300014469": "Other", "subitem_1523261968819": "Aspect ratio"}, {"subitem_1522299896455": "en", "subitem_1522300014469": "Other", "subitem_1523261968819": "Fully developed duct flow"}, {"subitem_1522299896455": "en", "subitem_1522300014469": "Other", "subitem_1523261968819": "Entrance region"}]}, "item_1617186626617": {"attribute_name": "Description", "attribute_value_mlt": [{"subitem_description": "This paper shows how the local heat transfer coefficients along rectangular ducts are affected by the aspect ratios of a duct varying in the range 1.0~2.6 in order to obtain the basic information on the heat transfer mechanisms in both square and rectangular ducts. It was found that the streamwise local heat transfer coefficients at a lower wall are higher than that at a side wall except the aspect ratio AP=1. As an aspect ratio increases, the local values on both walls increase, moreover the heat transfer coefficients at far downstream attain to the results obtained from the circular duct or the parallel plate duct. The dependency of an aspect ratio on the heat transfer characteristics of the rectangular duct is also presented.", "subitem_description_type": "Other"}, {"subitem_description": "紀要論文", "subitem_description_type": "Other"}]}, "item_1617186643794": {"attribute_name": "Publisher", "attribute_value_mlt": [{"subitem_1522300295150": "ja", "subitem_1522300316516": "琉球大学工学部"}]}, "item_1617186702042": {"attribute_name": "Language", "attribute_value_mlt": [{"subitem_1551255818386": "jpn"}]}, "item_1617186783814": {"attribute_name": "Identifier", "attribute_value_mlt": [{"subitem_identifier_type": "HDL", "subitem_identifier_uri": "http://hdl.handle.net/20.500.12000/17627"}]}, "item_1617186920753": {"attribute_name": "Source Identifier", "attribute_value_mlt": [{"subitem_1522646500366": "ISSN", "subitem_1522646572813": "0389-102X"}, {"subitem_1522646500366": "NCID", "subitem_1522646572813": "AN0025048X"}]}, "item_1617186941041": {"attribute_name": "Source Title", "attribute_value_mlt": [{"subitem_1522650068558": "ja", "subitem_1522650091861": "琉球大学工学部紀要"}]}, "item_1617187056579": {"attribute_name": "Bibliographic Information", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "1995-09", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "50", "bibliographicPageEnd": "33", "bibliographicPageStart": "27"}]}, "item_1617258105262": {"attribute_name": "Resource Type", "attribute_value_mlt": [{"resourcetype": "departmental bulletin paper", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_1617265215918": {"attribute_name": "Version Type", "attribute_value_mlt": [{"subitem_1522305645492": "VoR", "subitem_1600292170262": "http://purl.org/coar/version/c_970fb48d4fbd8a85"}]}, "item_1617605131499": {"attribute_name": "File", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_access", "download_preview_message": "", "file_order": 0, "filename": "No50p027.pdf", "future_date_message": "", "is_thumbnail": false, "mimetype": "", "size": 0, "url": {"objectType": "fulltext", "url": "https://u-ryukyu.repo.nii.ac.jp/record/2005592/files/No50p027.pdf"}, "version_id": "0ea09530-5143-4c74-9349-1cbaf2ed0ff5"}]}, "item_title": "長方形流路内の伝熱特性に関する研究 (アスペクト比の影響)", "item_type_id": "15", "owner": "1", "path": ["1642837872220", "1642838406845"], "permalink_uri": "http://hdl.handle.net/20.500.12000/17627", "pubdate": {"attribute_name": "PubDate", "attribute_value": "2010-07-28"}, "publish_date": "2010-07-28", "publish_status": "0", "recid": "2005592", "relation": {}, "relation_version_is_last": true, "title": ["長方形流路内の伝熱特性に関する研究 (アスペクト比の影響)"], "weko_shared_id": -1}
長方形流路内の伝熱特性に関する研究 (アスペクト比の影響)
http://hdl.handle.net/20.500.12000/17627
http://hdl.handle.net/20.500.12000/17627