{"created":"2022-01-28T01:16:41.368765+00:00","id":2005596,"links":{},"metadata":{"_buckets":{"deposit":"7963e585-0b63-4164-bdf1-723fce5721f9"},"_deposit":{"id":"2005596","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"2005596"},"status":"published"},"_oai":{"id":"oai:u-ryukyu.repo.nii.ac.jp:02005596","sets":["1642837622505:1642837855274:1642837869918","1642838403551:1642838406845"]},"author_link":[],"item_1617186331708":{"attribute_name":"Title","attribute_value_mlt":[{"subitem_1551255647225":"亜熱帯の塩害環境下におけるRC柱の耐震性能に関する実験的研究","subitem_1551255648112":"ja"},{"subitem_1551255647225":"An Experimental Study on Aseismatic Behavior of R/C Columns Under Chloride Attack Environment in Semitropical Region","subitem_1551255648112":"en"}]},"item_1617186419668":{"attribute_name":"Creator","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"山川, 哲雄","creatorNameLang":"ja"}]},{"creatorNames":[{"creatorName":"伊良波, 繁雄","creatorNameLang":"ja"}]},{"creatorNames":[{"creatorName":"玉城, 康哉","creatorNameLang":"ja"}]},{"creatorNames":[{"creatorName":"中山, 耕一","creatorNameLang":"ja"}]},{"creatorNames":[{"creatorName":"Yamakawa, Tetsuo","creatorNameLang":"en"}]},{"creatorNames":[{"creatorName":"Iraha, Shigeo","creatorNameLang":"en"}]},{"creatorNames":[{"creatorName":"Tamaki, Yasuya","creatorNameLang":"en"}]},{"creatorNames":[{"creatorName":"Nakayama, Koichi","creatorNameLang":"en"}]}]},"item_1617186476635":{"attribute_name":"Access Rights","attribute_value_mlt":[{"subitem_1522299639480":"open access","subitem_1600958577026":"http://purl.org/coar/access_right/c_abf2"}]},"item_1617186609386":{"attribute_name":"Subject","attribute_value_mlt":[{"subitem_1522299896455":"en","subitem_1522300014469":"Other","subitem_1523261968819":"R/C column"},{"subitem_1522299896455":"en","subitem_1522300014469":"Other","subitem_1523261968819":"Aseismatic behavior"},{"subitem_1522299896455":"en","subitem_1522300014469":"Other","subitem_1523261968819":"Corrosion"},{"subitem_1522299896455":"en","subitem_1522300014469":"Other","subitem_1523261968819":"Exposure test"},{"subitem_1522299896455":"en","subitem_1522300014469":"Other","subitem_1523261968819":"FRP grid"},{"subitem_1522299896455":"en","subitem_1522300014469":"Other","subitem_1523261968819":"Electrolytic corrosion test"}]},"item_1617186626617":{"attribute_name":"Description","attribute_value_mlt":[{"subitem_description":"In order to investigate the damage affecting aseismatic behavior of R/C columns, R/C column specimens sustained damage by electrolytic corrosion test were tested under a constant axial load and alternately repeated lateral loads by using the loading apparatus. Furthermore, R/C column specimens using FRP grid as hoops were tested in the similar manner. The other test specimens were offered to the exposure test in high salty environment in the semitropical and marine region at the coast in Okinawa. When the exposure test comes to an end several years after, these test specimens will be loaded laterally and vertically in order to discuss the damage affecting aseismatic behavior of R/C columns under chloride attack environment in the semitropical region.","subitem_description_type":"Other"},{"subitem_description":"紀要論文","subitem_description_type":"Other"}]},"item_1617186643794":{"attribute_name":"Publisher","attribute_value_mlt":[{"subitem_1522300295150":"ja","subitem_1522300316516":"琉球大学工学部"}]},"item_1617186702042":{"attribute_name":"Language","attribute_value_mlt":[{"subitem_1551255818386":"jpn"}]},"item_1617186783814":{"attribute_name":"Identifier","attribute_value_mlt":[{"subitem_identifier_type":"HDL","subitem_identifier_uri":"http://hdl.handle.net/20.500.12000/17650"}]},"item_1617186920753":{"attribute_name":"Source Identifier","attribute_value_mlt":[{"subitem_1522646500366":"ISSN","subitem_1522646572813":"0389-102X"},{"subitem_1522646500366":"NCID","subitem_1522646572813":"AN0025048X"}]},"item_1617186941041":{"attribute_name":"Source Title","attribute_value_mlt":[{"subitem_1522650068558":"ja","subitem_1522650091861":"琉球大学工学部紀要"}]},"item_1617187056579":{"attribute_name":"Bibliographic Information","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"1994-09","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"48","bibliographicPageEnd":"18","bibliographicPageStart":"1"}]},"item_1617258105262":{"attribute_name":"Resource Type","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_1617265215918":{"attribute_name":"Version Type","attribute_value_mlt":[{"subitem_1522305645492":"VoR","subitem_1600292170262":"http://purl.org/coar/version/c_970fb48d4fbd8a85"}]},"item_1617605131499":{"attribute_name":"File","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_access","filename":"No48p001.pdf","mimetype":"application/pdf","url":{"objectType":"fulltext","url":"https://u-ryukyu.repo.nii.ac.jp/record/2005596/files/No48p001.pdf"},"version_id":"424a2e9c-cd48-4764-aa68-b99527c76a34"}]},"item_title":"亜熱帯の塩害環境下におけるRC柱の耐震性能に関する実験的研究","item_type_id":"15","owner":"1","path":["1642837869918","1642838406845"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2010-08-02"},"publish_date":"2010-08-02","publish_status":"0","recid":"2005596","relation_version_is_last":true,"title":["亜熱帯の塩害環境下におけるRC柱の耐震性能に関する実験的研究"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2022-10-31T02:48:27.342751+00:00"}