{"_buckets": {"deposit": "b712c529-32bc-442a-9829-a8228ccfc926"}, "_deposit": {"id": "2006682", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "2006682"}, "status": "published"}, "_oai": {"id": "oai:u-ryukyu.repo.nii.ac.jp:02006682", "sets": ["1642837985553", "1642838406414"]}, "author_link": [], "item_1617186331708": {"attribute_name": "Title", "attribute_value_mlt": [{"subitem_1551255647225": "Determination of rare earth elements in small-volume seawater by off-line preconcentration system and inductively coupled plasma mass spectrometry", "subitem_1551255648112": "en"}]}, "item_1617186419668": {"attribute_name": "Creator", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Le, Luong Duc", "creatorNameLang": "en"}]}, {"creatorNames": [{"creatorName": "Shinjo, Ryuichi", "creatorNameLang": "en"}]}, {"creatorNames": [{"creatorName": "新城, 竜一", "creatorNameLang": "ja"}]}]}, "item_1617186476635": {"attribute_name": "Access Rights", "attribute_value_mlt": [{"subitem_1522299639480": "open access", "subitem_1600958577026": "http://purl.org/coar/access_right/c_abf2"}]}, "item_1617186609386": {"attribute_name": "Subject", "attribute_value_mlt": [{"subitem_1522299896455": "en", "subitem_1522300014469": "Other", "subitem_1523261968819": "Rare earth element"}, {"subitem_1522299896455": "en", "subitem_1522300014469": "Other", "subitem_1523261968819": "seawater"}, {"subitem_1522299896455": "en", "subitem_1522300014469": "Other", "subitem_1523261968819": "preconcentration"}, {"subitem_1522299896455": "en", "subitem_1522300014469": "Other", "subitem_1523261968819": "ICP-MS"}, {"subitem_1522299896455": "en", "subitem_1522300014469": "Other", "subitem_1523261968819": "NASS-5"}]}, "item_1617186626617": {"attribute_name": "Description", "attribute_value_mlt": [{"subitem_description": "An analytical method was developed for determining rare earth element (REE) concentrations in seawater using inductively coupled plasma mass spectrometry (ICP-MS). A relatively small-volume seawater sample (25 ml) was used for chemical separation. REE concentrations in 20-fold preconcentrated solution by an off-line preconcentration system were analyzed by ICP-MS with microflow nebulizer. The recoveries were mostly higher than 95%. To assess the analytical method, REE concentrations of the North Atlantic Surface Seawater (NASS-5), a seawater certified reference material, were measured with the proposed preconcentration procedure. Results obtained in this study are consistent with those of previous studies with good precision.", "subitem_description_type": "Other"}, {"subitem_description": "紀要論文", "subitem_description_type": "Other"}]}, "item_1617186643794": {"attribute_name": "Publisher", "attribute_value_mlt": [{"subitem_1522300295150": "ja", "subitem_1522300316516": "琉球大学理学部"}]}, "item_1617186702042": {"attribute_name": "Language", "attribute_value_mlt": [{"subitem_1551255818386": "eng"}]}, "item_1617186783814": {"attribute_name": "Identifier", "attribute_value_mlt": [{"subitem_identifier_type": "HDL", "subitem_identifier_uri": "http://hdl.handle.net/20.500.12000/22109"}]}, "item_1617186920753": {"attribute_name": "Source Identifier", "attribute_value_mlt": [{"subitem_1522646500366": "ISSN", "subitem_1522646572813": "0286-9640"}, {"subitem_1522646500366": "NCID", "subitem_1522646572813": "AN00250774"}]}, "item_1617186941041": {"attribute_name": "Source Title", "attribute_value_mlt": [{"subitem_1522650068558": "ja", "subitem_1522650091861": "琉球大学理学部紀要"}, {"subitem_1522650068558": "en", "subitem_1522650091861": "Bulletin of the College of Science. University of the Ryukyus"}]}, "item_1617187056579": {"attribute_name": "Bibliographic Information", "attribute_value_mlt": [{"bibliographicIssueNumber": "92", "bibliographicPageEnd": "22", "bibliographicPageStart": "17"}]}, "item_1617258105262": {"attribute_name": "Resource Type", "attribute_value_mlt": [{"resourcetype": "departmental bulletin paper", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_1617265215918": {"attribute_name": "Version Type", "attribute_value_mlt": [{"subitem_1522305645492": "NA", "subitem_1600292170262": "http://purl.org/coar/version/c_be7fb7dd8ff6fe43"}]}, "item_1617605131499": {"attribute_name": "File", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_access", "download_preview_message": "", "file_order": 0, "filename": "No92p017.pdf", "future_date_message": "", "is_thumbnail": false, "mimetype": "", "size": 0, "url": {"objectType": "fulltext", "url": "https://u-ryukyu.repo.nii.ac.jp/record/2006682/files/No92p017.pdf"}, "version_id": "1dbea7c3-69ef-44a6-b332-b21b13321a44"}]}, "item_title": "Determination of rare earth elements in small-volume seawater by off-line preconcentration system and inductively coupled plasma mass spectrometry", "item_type_id": "15", "owner": "1", "path": ["1642837985553", "1642838406414"], "permalink_uri": "http://hdl.handle.net/20.500.12000/22109", "pubdate": {"attribute_name": "PubDate", "attribute_value": "2011-11-09"}, "publish_date": "2011-11-09", "publish_status": "0", "recid": "2006682", "relation": {}, "relation_version_is_last": true, "title": ["Determination of rare earth elements in small-volume seawater by off-line preconcentration system and inductively coupled plasma mass spectrometry"], "weko_shared_id": -1}
Determination of rare earth elements in small-volume seawater by off-line preconcentration system and inductively coupled plasma mass spectrometry
http://hdl.handle.net/20.500.12000/22109
http://hdl.handle.net/20.500.12000/22109