{"created":"2022-01-28T04:10:49.530232+00:00","id":2007034,"links":{},"metadata":{"_buckets":{"deposit":"00effef8-7a0e-443f-b16b-3d897c303356"},"_deposit":{"id":"2007034","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"2007034"},"status":"published"},"_oai":{"id":"oai:u-ryukyu.repo.nii.ac.jp:02007034","sets":["1642837622505:1642837722116:1642837722903","1642838403551:1642838406845"]},"author_link":[],"item_1617186331708":{"attribute_name":"Title","attribute_value_mlt":[{"subitem_1551255647225":"器具の相違による液性限界値のちがいと一点法の適用について","subitem_1551255648112":"ja"},{"subitem_1551255647225":"Laboratory Studies of the Two Typical L.L Devices and the One-Point L.L.Method","subitem_1551255648112":"en"}]},"item_1617186419668":{"attribute_name":"Creator","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"上原, 万成","creatorNameLang":"ja"}]},{"creatorNames":[{"creatorName":"Uehara, Hosei","creatorNameLang":"en"}]}]},"item_1617186476635":{"attribute_name":"Access Rights","attribute_value_mlt":[{"subitem_1522299639480":"open access","subitem_1600958577026":"http://purl.org/coar/access_right/c_abf2"}]},"item_1617186626617":{"attribute_name":"Description","attribute_value_mlt":[{"subitem_description":"The liquid limit test is perhaps the oldest and most widely accepted of all the laboratory tests of soils.However,the devices and procedures employed by various countries and organizations differ.Consequently,the test results give different values.Also the imperfections of the devices and procedures naturally produce the experimental errors.For such problems,the investigations into the devices,procedures,short-cut methods,and new apparatus have been reported in various countries.\\nThis paper presents the liquid limit results from a Japanese device(JIStype) and an American device (ASTM type)for comparison ofthe values,and discusses the applicability of the one-point liquid limit method for the soils in Okinawa. It was found that the ASTM type device gives lower values than the JIS type device and the difference in terms of moisture content between both values is given by the equation,△=0.133 L.L.I-1.018,where L.L is the JIS\\ntype value.The indices tanβ for the ASTM type device and for the JIS type device were found to be 0.130 and 0.098 respectively.For normal classification purposes these values gave the results well within the accuracy required in normal work.","subitem_description_type":"Other"},{"subitem_description":"紀要論文","subitem_description_type":"Other"}]},"item_1617186643794":{"attribute_name":"Publisher","attribute_value_mlt":[{"subitem_1522300295150":"ja","subitem_1522300316516":"琉球大学理工学部"},{"subitem_1522300295150":"en","subitem_1522300316516":"Science and Engineering Division, University of the Ryukyus"}]},"item_1617186702042":{"attribute_name":"Language","attribute_value_mlt":[{"subitem_1551255818386":"jpn"}]},"item_1617186783814":{"attribute_name":"Identifier","attribute_value_mlt":[{"subitem_identifier_type":"HDL","subitem_identifier_uri":"http://hdl.handle.net/20.500.12000/23830"}]},"item_1617186920753":{"attribute_name":"Source Identifier","attribute_value_mlt":[{"subitem_1522646500366":"ISSN","subitem_1522646572813":"0387-429X"},{"subitem_1522646500366":"NCID","subitem_1522646572813":"AN00250785"}]},"item_1617186941041":{"attribute_name":"Source Title","attribute_value_mlt":[{"subitem_1522650068558":"ja","subitem_1522650091861":"琉球大学理工学部紀要 工学篇"}]},"item_1617187056579":{"attribute_name":"Bibliographic Information","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"1969-04","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"2","bibliographicPageEnd":"126","bibliographicPageStart":"111"}]},"item_1617258105262":{"attribute_name":"Resource Type","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_1617265215918":{"attribute_name":"Version Type","attribute_value_mlt":[{"subitem_1522305645492":"NA","subitem_1600292170262":"http://purl.org/coar/version/c_be7fb7dd8ff6fe43"}]},"item_1617605131499":{"attribute_name":"File","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_access","filename":"NO2P111.pdf","mimetype":"application/pdf","url":{"objectType":"fulltext","url":"https://u-ryukyu.repo.nii.ac.jp/record/2007034/files/NO2P111.pdf"},"version_id":"2cf49f94-05d6-401e-a3c0-63915db59584"}]},"item_title":"器具の相違による液性限界値のちがいと一点法の適用について","item_type_id":"15","owner":"1","path":["1642837722903","1642838406845"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2012-03-19"},"publish_date":"2012-03-19","publish_status":"0","recid":"2007034","relation_version_is_last":true,"title":["器具の相違による液性限界値のちがいと一点法の適用について"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2022-10-31T03:13:39.862579+00:00"}