{"created":"2022-02-01T06:40:37.572453+00:00","id":2011287,"links":{},"metadata":{"_buckets":{"deposit":"1391188b-9187-48ee-bd88-7aaece9e08da"},"_deposit":{"id":"2011287","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"2011287"},"status":"published"},"_oai":{"id":"oai:u-ryukyu.repo.nii.ac.jp:02011287","sets":["1642838163960:1642838338003","1642838403551:1642838406414"]},"author_link":[],"item_1617186331708":{"attribute_name":"Title","attribute_value_mlt":[{"subitem_1551255647225":"Development of Rapid Sampling System of Atmospheric Water Vapor for Tritium Measurement","subitem_1551255648112":"en"}]},"item_1617186419668":{"attribute_name":"Creator","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Akata, Naofumi","creatorNameLang":"en"}]},{"creatorNames":[{"creatorName":"Kakiuchi, Hideki","creatorNameLang":"en"}]},{"creatorNames":[{"creatorName":"Tanaka, Masahiro","creatorNameLang":"en"}]},{"creatorNames":[{"creatorName":"Shima, Nagayoshi","creatorNameLang":"en"}]},{"creatorNames":[{"creatorName":"Shiroma, Yoshitaka","creatorNameLang":"en"}]},{"creatorNames":[{"creatorName":"Tokonami, Shinji","creatorNameLang":"en"}]},{"creatorNames":[{"creatorName":"Hosoda, Masahiro","creatorNameLang":"en"}]},{"creatorNames":[{"creatorName":"Ishikawa, Yoshio","creatorNameLang":"en"}]},{"creatorNames":[{"creatorName":"Furukawa, Masahide","creatorNameLang":"en"}]},{"creatorNames":[{"creatorName":"Sanada, Tetsuya","creatorNameLang":"en"}]}]},"item_1617186476635":{"attribute_name":"Access Rights","attribute_value_mlt":[{"subitem_1522299639480":"open access","subitem_1600958577026":"http://purl.org/coar/access_right/c_abf2"}]},"item_1617186499011":{"attribute_name":"Rights","attribute_value_mlt":[{"subitem_1522650717957":"ja","subitem_1522651041219":"©2018 The Japan Society of Plasma Science and Nuclear Fusion Research"}]},"item_1617186609386":{"attribute_name":"Subject","attribute_value_mlt":[{"subitem_1522299896455":"en","subitem_1522300014469":"Other","subitem_1523261968819":"tritium"},{"subitem_1522299896455":"en","subitem_1522300014469":"Other","subitem_1523261968819":"water vapor"},{"subitem_1522299896455":"en","subitem_1522300014469":"Other","subitem_1523261968819":"atmospheric environment"},{"subitem_1522299896455":"en","subitem_1522300014469":"Other","subitem_1523261968819":"rapid-sampling system"},{"subitem_1522299896455":"en","subitem_1522300014469":"Other","subitem_1523261968819":"short term"}]},"item_1617186626617":{"attribute_name":"Description","attribute_value_mlt":[{"subitem_description":"We have developed a rapid sampling system for measuring the tritium in atmospheric water vapor. The system consists of a high-efficiency particulate air filter cartridge, an oil-free compressor, a water-vapor-separating module with hollow fiber membranes, two cold traps, and an oil-free rotary pump. Compressed air (0.4 - 0.7MPa) is introduced into the water-vapor-separation module, which consists of a stainless steel column containing polyimide membrane tubes. Water vapor permeates through the tubes and is collected by cold traps cooled with dry ice and ethanol. The module is heated with a flexible heater to control its temperature. We have determined the recovery yields under various sampling conditions and find that this system can collect atmospheric water vapor with a recovery yield of >99%. This system can thus be a useful tool for understanding short-term observations of tritium in atmospheric water vapor.","subitem_description_type":"Other"},{"subitem_description":"論文","subitem_description_type":"Other"}]},"item_1617186643794":{"attribute_name":"Publisher","attribute_value_mlt":[{"subitem_1522300295150":"en","subitem_1522300316516":"The Japan Society of Plasma Science and Nuclear Fusion Research"},{"subitem_1522300295150":"ja","subitem_1522300316516":"プラズマ・核融合学会"}]},"item_1617186702042":{"attribute_name":"Language","attribute_value_mlt":[{"subitem_1551255818386":"eng"}]},"item_1617186783814":{"attribute_name":"Identifier","attribute_value_mlt":[{"subitem_identifier_type":"HDL","subitem_identifier_uri":"http://hdl.handle.net/20.500.12000/47467"}]},"item_1617186920753":{"attribute_name":"Source Identifier","attribute_value_mlt":[{"subitem_1522646500366":"ISSN","subitem_1522646572813":"1880-6821"}]},"item_1617186941041":{"attribute_name":"Source Title","attribute_value_mlt":[{"subitem_1522650068558":"en","subitem_1522650091861":"Plasma and Fusion Research"}]},"item_1617187056579":{"attribute_name":"Bibliographic Information","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2018-06-12","bibliographicIssueDateType":"Issued"},"bibliographicVolumeNumber":"13"}]},"item_1617258105262":{"attribute_name":"Resource Type","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_1617265215918":{"attribute_name":"Version Type","attribute_value_mlt":[{"subitem_1522305645492":"VoR","subitem_1600292170262":"http://purl.org/coar/version/c_970fb48d4fbd8a85"}]},"item_1617353299429":{"attribute_name":"Relation","attribute_value_mlt":[{"subitem_1522306287251":{"subitem_1522306382014":"DOI","subitem_1522306436033":"https://doi.org/10.1585/pfr.13.3405064"}},{"subitem_1522306287251":{"subitem_1522306382014":"DOI","subitem_1522306436033":"https://doi.org/10.1585/pfr.13.3405064"}}]},"item_1617605131499":{"attribute_name":"File","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_access","filename":"13_3405064.pdf","mimetype":"application/pdf","url":{"objectType":"fulltext","url":"https://u-ryukyu.repo.nii.ac.jp/record/2011287/files/13_3405064.pdf"},"version_id":"2a23cbfa-c925-488e-bb7e-002a2a15d7be"}]},"item_title":"Development of Rapid Sampling System of Atmospheric Water Vapor for Tritium Measurement","item_type_id":"15","owner":"1","path":["1642838338003","1642838406414"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2020-12-11"},"publish_date":"2020-12-11","publish_status":"0","recid":"2011287","relation_version_is_last":true,"title":["Development of Rapid Sampling System of Atmospheric Water Vapor for Tritium Measurement"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-08-03T05:38:04.984923+00:00"}