{"created":"2022-02-22T04:15:09.962378+00:00","id":2016143,"links":{},"metadata":{"_buckets":{"deposit":"21d4602a-c3f8-40dd-bdf2-4a6c27442a88"},"_deposit":{"id":"2016143","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"2016143"},"status":"published"},"_oai":{"id":"oai:u-ryukyu.repo.nii.ac.jp:02016143","sets":["1642838163960:1642838198944:1642838199408:1642838217678","1642838403551:1642838412624"]},"author_link":[],"item_1617186331708":{"attribute_name":"Title","attribute_value_mlt":[{"subitem_1551255647225":"[症例報告]Displacement of dental implant into the maxilla : A case report","subitem_1551255648112":"ja"}]},"item_1617186419668":{"attribute_name":"Creator","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Kano, Takeshi","creatorNameLang":"en"}]},{"creatorNames":[{"creatorName":"Sunakawa, Hajime","creatorNameLang":"en"}]},{"creatorNames":[{"creatorName":"Arasaki, Akira","creatorNameLang":"en"}]},{"creatorNames":[{"creatorName":"Arakaki, Keiichi","creatorNameLang":"en"}]},{"creatorNames":[{"creatorName":"Kuninaka, Rika","creatorNameLang":"en"}]},{"creatorNames":[{"creatorName":"Takara, Kiyomi","creatorNameLang":"en"}]},{"creatorNames":[{"creatorName":"Morita, Nanae","creatorNameLang":"en"}]}]},"item_1617186476635":{"attribute_name":"Access Rights","attribute_value_mlt":[{"subitem_1522299639480":"open access","subitem_1600958577026":"http://purl.org/coar/access_right/c_abf2"}]},"item_1617186499011":{"attribute_name":"Rights","attribute_value_mlt":[{"subitem_1522650717957":"ja","subitem_1522651041219":"琉球医学会"}]},"item_1617186609386":{"attribute_name":"Subject","attribute_value_mlt":[{"subitem_1522299896455":"en","subitem_1522300014469":"Other","subitem_1523261968819":"foreign body"},{"subitem_1522299896455":"en","subitem_1522300014469":"Other","subitem_1523261968819":"maxilla"},{"subitem_1522299896455":"en","subitem_1522300014469":"Other","subitem_1523261968819":"dental implant"},{"subitem_1522299896455":"en","subitem_1522300014469":"Other","subitem_1523261968819":"maxillary sinus"}]},"item_1617186626617":{"attribute_name":"Description","attribute_value_mlt":[{"subitem_description":"Oral surgeons sometimes encounter patients with foreign bodies in their jaws who undergo dental treatment. Occasionally it is difficult to extract them. This paper reports a rare case of a displaced dental implant into the maxillary sinus. An 83-year-old man was referred to our department for a displaced dental implant. Radiographs showed a displaced dental implant in the left maxilla. We removed the dental implant from the maxillary sinus under local anesthesia. The patient recovered uneventfully with no evidence of sinus infection.","subitem_description_type":"Other"},{"subitem_description":"論文","subitem_description_type":"Other"}]},"item_1617186643794":{"attribute_name":"Publisher","attribute_value_mlt":[{"subitem_1522300295150":"ja","subitem_1522300316516":"琉球医学会"},{"subitem_1522300295150":"en","subitem_1522300316516":"Ryukyu Medical Association"}]},"item_1617186702042":{"attribute_name":"Language","attribute_value_mlt":[{"subitem_1551255818386":"eng"}]},"item_1617186920753":{"attribute_name":"Source Identifier","attribute_value_mlt":[{"subitem_1522646500366":"ISSN","subitem_1522646572813":"1346888X"},{"subitem_1522646500366":"ISSN","subitem_1522646572813":"0289-1530"},{"subitem_1522646500366":"NCID","subitem_1522646572813":"AN10369445"}]},"item_1617186941041":{"attribute_name":"Source Title","attribute_value_mlt":[{"subitem_1522650068558":"ja","subitem_1522650091861":"琉球医学会誌 = Ryukyu Medical Journal"}]},"item_1617187056579":{"attribute_name":"Bibliographic Information","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2002","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"2","bibliographicPageEnd":"106","bibliographicPageStart":"103","bibliographicVolumeNumber":"21"}]},"item_1617258105262":{"attribute_name":"Resource Type","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_1617265215918":{"attribute_name":"Version Type","attribute_value_mlt":[{"subitem_1522305645492":"VoR","subitem_1600292170262":"http://purl.org/coar/version/c_970fb48d4fbd8a85"}]},"item_1617605131499":{"attribute_name":"File","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_access","filename":"v21p103.pdf","mimetype":"application/pdf","url":{"objectType":"fulltext","url":"https://u-ryukyu.repo.nii.ac.jp/record/2016143/files/v21p103.pdf"},"version_id":"8365d576-0eb3-478c-9387-94ffbc2c60fb"}]},"item_title":"[症例報告]Displacement of dental implant into the maxilla : A case report","item_type_id":"15","owner":"1","path":["1642838217678","1642838412624"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2010-07-02"},"publish_date":"2010-07-02","publish_status":"0","recid":"2016143","relation_version_is_last":true,"title":["[症例報告]Displacement of dental implant into the maxilla : A case report"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2022-10-31T07:51:14.778975+00:00"}