{"created":"2023-03-31T05:38:55.057153+00:00","id":2019671,"links":{},"metadata":{"_buckets":{"deposit":"bc5c205c-7a67-443b-8562-0ff1f38bde6e"},"_deposit":{"created_by":8,"id":"2019671","owner":"8","owners":[8],"owners_ext":{"displayname":"ryukyu_lib","username":null},"pid":{"revision_id":0,"type":"depid","value":"2019671"},"status":"published"},"_oai":{"id":"oai:u-ryukyu.repo.nii.ac.jp:02019671","sets":["1642838163960:1642838338003","1642838403551:1642838412624"]},"author_link":[],"item_1617186331708":{"attribute_name":"Title","attribute_value_mlt":[{"subitem_1551255647225":"Usefulness of INTELLiVENT-ASV for postoperative ventilator-associated pneumonia: a case report","subitem_1551255648112":"en"}]},"item_1617186419668":{"attribute_name":"Creator","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Taira, Takayuki","creatorNameLang":"en"}]},{"creatorNames":[{"creatorName":"Fuchigami, Tatsuya","creatorNameLang":"en"}]},{"creatorNames":[{"creatorName":"Hayashi, Misuzu","creatorNameLang":"en"}]},{"creatorNames":[{"creatorName":"Kamizato, Kouta","creatorNameLang":"en"}]},{"creatorNames":[{"creatorName":"Teruya, Kouji","creatorNameLang":"en"}]},{"creatorNames":[{"creatorName":"Kakinohana, Manabu","creatorNameLang":"en"}]}]},"item_1617186476635":{"attribute_name":"Access Rights","attribute_value_mlt":[{"subitem_1522299639480":"open access","subitem_1600958577026":"http://purl.org/coar/access_right/c_abf2"}]},"item_1617186499011":{"attribute_name":"Rights","attribute_value_mlt":[{"subitem_1522650717957":"en","subitem_1522651041219":"© The Author(s). 2019"},{"subitem_1522650717957":"en","subitem_1522650727486":"http://creativecommons.org/licenses/by/4.0/","subitem_1522651041219":"This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made."}]},"item_1617186609386":{"attribute_name":"Subject","attribute_value_mlt":[{"subitem_1522299896455":"en","subitem_1522300014469":"Other","subitem_1523261968819":"Artificial respiration"},{"subitem_1522299896455":"en","subitem_1522300014469":"Other","subitem_1523261968819":"INTELLiVENT® iASV"},{"subitem_1522299896455":"en","subitem_1522300014469":"Other","subitem_1523261968819":"Ventilator-associated pneumonia"}]},"item_1617186626617":{"attribute_name":"Description","attribute_value_mlt":[{"subitem_description":"Background: INTELLiVENT®-ASV (iASV) is a respiration mode on the Hamilton G5. The ventilator uses a closed-loop mechanism that automatically adjusts settings related to oxygenation and ventilation.\nCase presentation: A 47-year-old man underwent reconstruction surgery with free musculocutaneous flap for tongue resection. After surgery, the patient entered the ICU, and the iASV, which automatically changed only the percent minute volume (%MV) in respiration mode, was selected. On the second day, ventilator-associated pneumonia (VAP) was diagnosed, and the antibiotic treatment was changed. Using the settings of the iASV, automated FiO2 and positive end-expiratory pressure (PEEP) control were added to the ventilator mode. The patient’s oxygenation was improved.\nConclusions: In a patient who developed VAP after surgery, ventilation was continued using iASV, and automated changes in PEEP and FiO2 settings were successfully made according to the open lung strategy, under short-staffed circumstances.","subitem_description_language":"en","subitem_description_type":"Abstract"}]},"item_1617186643794":{"attribute_name":"Publisher","attribute_value_mlt":[{"subitem_1522300295150":"en","subitem_1522300316516":"SpringerOpen"}]},"item_1617186702042":{"attribute_name":"Language","attribute_value_mlt":[{"subitem_1551255818386":"eng"}]},"item_1617186941041":{"attribute_name":"Source Title","attribute_value_mlt":[{"subitem_1522650068558":"en","subitem_1522650091861":"JA Clinical Reports"}]},"item_1617187056579":{"attribute_name":"Bibliographic Information","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2019-06-29","bibliographicIssueDateType":"Issued"}}]},"item_1617258105262":{"attribute_name":"Resource Type","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_1617265215918":{"attribute_name":"Version Type","attribute_value_mlt":[{"subitem_1522305645492":"VoR","subitem_1600292170262":"http://purl.org/coar/version/c_970fb48d4fbd8a85"}]},"item_1617353299429":{"attribute_name":"Relation","attribute_value_mlt":[{"subitem_1522306287251":{"subitem_1522306382014":"DOI","subitem_1522306436033":"https://doi.org/10.1186/s40981-019-0262-x"}}]},"item_1617605131499":{"attribute_name":"File","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_access","date":[{"dateType":"Available","dateValue":"2023-03-31"}],"filename":"s40981-019-0262-x.pdf","filesize":[{"value":"555 KB"}],"url":{"objectType":"fulltext","url":"https://u-ryukyu.repo.nii.ac.jp/record/2019671/files/s40981-019-0262-x.pdf"},"version_id":"be75969b-a6d9-4a6c-b761-2c23b729822b"}]},"item_title":"Usefulness of INTELLiVENT-ASV for postoperative ventilator-associated pneumonia: a case report","item_type_id":"59","owner":"8","path":["1642838338003","1642838412624"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2023-03-31"},"publish_date":"2023-03-31","publish_status":"0","recid":"2019671","relation_version_is_last":true,"title":["Usefulness of INTELLiVENT-ASV for postoperative ventilator-associated pneumonia: a case report"],"weko_creator_id":"8","weko_shared_id":-1},"updated":"2023-08-03T05:44:57.496592+00:00"}