{"_buckets": {"deposit": "9da767a0-016d-46ac-ba6f-c251e4277af7"}, "_deposit": {"id": "2000812", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "2000812"}, "status": "published"}, "_oai": {"id": "oai:u-ryukyu.repo.nii.ac.jp:02000812", "sets": ["1642838338003", "1642838406845"]}, "author_link": [], "item_1617186331708": {"attribute_name": "Title", "attribute_value_mlt": [{"subitem_1551255647225": "\u30b9\u30e9\u30c3\u30c8\u3092\u7528\u3044\u305f\u5f8c\u5411\u304d\u30b9\u30c6\u30c3\u30d7\u4e0b\u6d41\u306e\u518d\u4ed8\u7740\u9818\u57df\u306e\u71b1\u4f1d\u9054\u4fc3\u9032", "subitem_1551255648112": "ja"}, {"subitem_1551255647225": "Heat Thansfer Enhancement Using Slat at Reattachment Region Downstream of Backward-Facing Step", "subitem_1551255648112": "en"}]}, "item_1617186419668": {"attribute_name": "Creator", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "\u89aa\u5ddd, \u517c\u52c7", "creatorNameLang": "ja"}]}, {"creatorNames": [{"creatorName": "\u6589\u85e4, \u6b66\u53f2", "creatorNameLang": "ja"}]}, {"creatorNames": [{"creatorName": "\u7167\u5c4b, \u529f", "creatorNameLang": "ja"}]}, {"creatorNames": [{"creatorName": "\u99ac\u6e15, \u5e7e\u592b", "creatorNameLang": "ja"}]}, {"creatorNames": [{"creatorName": "Oyakawa, Kenyu", "creatorNameLang": "en"}]}, {"creatorNames": [{"creatorName": "Saitoh, Takeshi", "creatorNameLang": "en"}]}, {"creatorNames": [{"creatorName": "Teruya, Isao", "creatorNameLang": "en"}]}, {"creatorNames": [{"creatorName": "Mabuchi, Ikuo", "creatorNameLang": "en"}]}]}, "item_1617186476635": {"attribute_name": "Access Rights", "attribute_value_mlt": [{"subitem_1522299639480": "open access", "subitem_1600958577026": "http://purl.org/coar/access_right/c_abf2"}]}, "item_1617186499011": {"attribute_name": "Rights", "attribute_value_mlt": [{"subitem_1522650717957": "ja", "subitem_1522651041219": "Copyright (c) 1995 \u65e5\u672c\u6a5f\u68b0\u5b66\u4f1a"}]}, "item_1617186609386": {"attribute_name": "Subject", "attribute_value_mlt": [{"subitem_1522299896455": "en", "subitem_1522300014469": "Other", "subitem_1523261968819": "Forced Convection"}, {"subitem_1522299896455": "en", "subitem_1522300014469": "Other", "subitem_1523261968819": "Heat Transfer Enhancement"}, {"subitem_1522299896455": "en", "subitem_1522300014469": "Other", "subitem_1523261968819": "Separation"}, {"subitem_1522299896455": "en", "subitem_1522300014469": "Other", "subitem_1523261968819": "Shear Flow"}, {"subitem_1522299896455": "en", "subitem_1522300014469": "Other", "subitem_1523261968819": "Expansion Ratio"}, {"subitem_1522299896455": "en", "subitem_1522300014469": "Other", "subitem_1523261968819": "Reattachment Region"}, {"subitem_1522299896455": "en", "subitem_1522300014469": "Other", "subitem_1523261968819": "Pressure Loss"}, {"subitem_1522299896455": "en", "subitem_1522300014469": "Other", "subitem_1523261968819": "Performance Ratio"}]}, "item_1617186626617": {"attribute_name": "Description", "attribute_value_mlt": [{"subitem_description": "The effects on the local heat transfer and pressure coefficients of a slat downstream of a backward-facing step were investigated. The inclinations of the slat placed on the wall opposite the step were varied in the range of \u03b8 = 10\uff5e60\u00b0 for both slat lengths of 20 mm and 30 mm, with the aim of augmenting and controlling the heat transfer characteristics. The reattachment region of the main flow shifted upstream due to the increase of the amount of circulating bubbles formed behind the slat when the inclination angle was increased, which enhanced the heat transfer in the recirculating region. These tendencies are marked with a large expansion ratio. It was also found that the performance ratio \u03b7 (the ratio of averaged heat transfer with a slat to that without a slat under the condition of equivalent pumping power) is larger than unity.", "subitem_description_type": "Other"}, {"subitem_description": "\u8ad6\u6587", "subitem_description_type": "Other"}]}, "item_1617186643794": {"attribute_name": "Publisher", "attribute_value_mlt": [{"subitem_1522300295150": "ja", "subitem_1522300316516": "\u65e5\u672c\u6a5f\u68b0\u5b66\u4f1a"}]}, "item_1617186702042": {"attribute_name": "Language", "attribute_value_mlt": [{"subitem_1551255818386": "jpn"}]}, "item_1617186783814": {"attribute_name": "Identifier", "attribute_value_mlt": [{"subitem_identifier_type": "HDL", "subitem_identifier_uri": "http://hdl.handle.net/20.500.12000/241"}]}, "item_1617186920753": {"attribute_name": "Source Identifier", "attribute_value_mlt": [{"subitem_1522646500366": "ISSN", "subitem_1522646572813": "03875016"}, {"subitem_1522646500366": "NCID", "subitem_1522646572813": "AN00187441"}]}, "item_1617186941041": {"attribute_name": "Source Title", "attribute_value_mlt": [{"subitem_1522650068558": "ja", "subitem_1522650091861": "\u65e5\u672c\u6a5f\u68b0\u5b66\u4f1a\u8ad6\u6587\u96c6. B\u7de8"}, {"subitem_1522650068558": "en", "subitem_1522650091861": "Transactions of the Japan Society of Mechanical Engineers. B"}]}, "item_1617187056579": {"attribute_name": "Bibliographic Information", "attribute_value_mlt": [{"bibliographicIssueNumber": "592", "bibliographicPageEnd": "199", "bibliographicPageStart": "194", "bibliographicVolumeNumber": "61"}]}, "item_1617258105262": {"attribute_name": "Resource Type", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_1617265215918": {"attribute_name": "Version Type", "attribute_value_mlt": [{"subitem_1522305645492": "VoR", "subitem_1600292170262": "http://purl.org/coar/version/c_970fb48d4fbd8a85"}]}, "item_1617605131499": {"attribute_name": "File", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_access", "download_preview_message": "", "file_order": 0, "filename": "teruya_i04.pdf", "future_date_message": "", "is_thumbnail": false, "mimetype": "", "size": 0, "url": {"objectType": "fulltext", "url": "https://u-ryukyu.repo.nii.ac.jp/record/2000812/files/teruya_i04.pdf"}, "version_id": "86ec131c-ac83-4ef3-9bef-5aa16a4da0f3"}]}, "item_title": "\u30b9\u30e9\u30c3\u30c8\u3092\u7528\u3044\u305f\u5f8c\u5411\u304d\u30b9\u30c6\u30c3\u30d7\u4e0b\u6d41\u306e\u518d\u4ed8\u7740\u9818\u57df\u306e\u71b1\u4f1d\u9054\u4fc3\u9032", "item_type_id": "15", "owner": "1", "path": ["1642838338003", "1642838406845"], "permalink_uri": "http://hdl.handle.net/20.500.12000/241", "pubdate": {"attribute_name": "PubDate", "attribute_value": "2007-03-04"}, "publish_date": "2007-03-04", "publish_status": "0", "recid": "2000812", "relation": {}, "relation_version_is_last": true, "title": ["\u30b9\u30e9\u30c3\u30c8\u3092\u7528\u3044\u305f\u5f8c\u5411\u304d\u30b9\u30c6\u30c3\u30d7\u4e0b\u6d41\u306e\u518d\u4ed8\u7740\u9818\u57df\u306e\u71b1\u4f1d\u9054\u4fc3\u9032"], "weko_shared_id": -1}
  1. 学術雑誌論文
  2. その他
  1. 部局別インデックス
  2. 工学部

スラットを用いた後向きステップ下流の再付着領域の熱伝達促進

http://hdl.handle.net/20.500.12000/241
http://hdl.handle.net/20.500.12000/241
0f10612c-a797-4fa9-a08e-bf0ef524cd54
名前 / ファイル ライセンス アクション
teruya_i04.pdf teruya_i04.pdf
Item type デフォルトアイテムタイプ(フル)(1)
公開日 2007-03-04
タイトル
タイトル スラットを用いた後向きステップ下流の再付着領域の熱伝達促進
言語 ja
作成者 親川, 兼勇

× 親川, 兼勇

ja 親川, 兼勇

斉藤, 武史

× 斉藤, 武史

ja 斉藤, 武史

照屋, 功

× 照屋, 功

ja 照屋, 功

馬渕, 幾夫

× 馬渕, 幾夫

ja 馬渕, 幾夫

Oyakawa, Kenyu

× Oyakawa, Kenyu

en Oyakawa, Kenyu

Saitoh, Takeshi

× Saitoh, Takeshi

en Saitoh, Takeshi

Teruya, Isao

× Teruya, Isao

en Teruya, Isao

Mabuchi, Ikuo

× Mabuchi, Ikuo

en Mabuchi, Ikuo

アクセス権
アクセス権 open access
アクセス権URI http://purl.org/coar/access_right/c_abf2
権利情報
言語 ja
権利情報 Copyright (c) 1995 日本機械学会
主題
言語 en
主題Scheme Other
主題 Forced Convection
言語 en
主題Scheme Other
主題 Heat Transfer Enhancement
言語 en
主題Scheme Other
主題 Separation
言語 en
主題Scheme Other
主題 Shear Flow
言語 en
主題Scheme Other
主題 Expansion Ratio
言語 en
主題Scheme Other
主題 Reattachment Region
言語 en
主題Scheme Other
主題 Pressure Loss
言語 en
主題Scheme Other
主題 Performance Ratio
内容記述
内容記述タイプ Other
内容記述 The effects on the local heat transfer and pressure coefficients of a slat downstream of a backward-facing step were investigated. The inclinations of the slat placed on the wall opposite the step were varied in the range of θ = 10~60° for both slat lengths of 20 mm and 30 mm, with the aim of augmenting and controlling the heat transfer characteristics. The reattachment region of the main flow shifted upstream due to the increase of the amount of circulating bubbles formed behind the slat when the inclination angle was increased, which enhanced the heat transfer in the recirculating region. These tendencies are marked with a large expansion ratio. It was also found that the performance ratio η (the ratio of averaged heat transfer with a slat to that without a slat under the condition of equivalent pumping power) is larger than unity.
内容記述タイプ Other
内容記述 論文
出版者
言語 ja
出版者 日本機械学会
言語
言語 jpn
資源タイプ
資源タイプ journal article
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
出版タイプ
出版タイプ VoR
出版タイプResource http://purl.org/coar/version/c_970fb48d4fbd8a85
識別子
識別子 http://hdl.handle.net/20.500.12000/241
識別子タイプ HDL
収録物識別子
収録物識別子タイプ ISSN
収録物識別子 03875016
収録物識別子タイプ NCID
収録物識別子 AN00187441
収録物名
言語 ja
収録物名 日本機械学会論文集. B編
書誌情報
巻 61, 号 592, p. 194-199
戻る
0
views
See details
Views

Versions

Ver.1 2022-01-24 08:36:48.355896
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON

確認


Powered by WEKO3


Powered by WEKO3