ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

{"_buckets": {"deposit": "ce33cf69-7750-4a1a-8b5c-e891571e0a61"}, "_deposit": {"id": "2007013", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "2007013"}, "status": "published"}, "_oai": {"id": "oai:u-ryukyu.repo.nii.ac.jp:02007013", "sets": ["1642838003490", "1642838406414"]}, "author_link": [], "item_1617186331708": {"attribute_name": "Title", "attribute_value_mlt": [{"subitem_1551255647225": "\u9285\u3068\u30ab\u30c9\u30df\u30a6\u30e0\u306e\u6db2\u30fb\u6db2\u6eb6\u5a92\u62bd\u51fa\uff0d\u9023\u7d9a\u62bd\u51fa\u6cd5\u306e\u9069\u7528\uff0d", "subitem_1551255648112": "ja"}, {"subitem_1551255647225": "The Liquid-Liquid Extraction of Copper and Cadmium by means of Continuous Extraction Technique", "subitem_1551255648112": "en"}]}, "item_1617186419668": {"attribute_name": "Creator", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "\u6842, \u5e78\u662d", "creatorNameLang": "ja"}]}, {"creatorNames": [{"creatorName": "\u6ca2\u5cbb, \u5eb7\u5b50", "creatorNameLang": "ja"}]}, {"creatorNames": [{"creatorName": "\u5d0e\u539f, \u5343\u9db4\u5b50", "creatorNameLang": "ja"}]}, {"creatorNames": [{"creatorName": "\u540d\u57ce, \u5b5d\u5b50", "creatorNameLang": "ja"}]}, {"creatorNames": [{"creatorName": "\u548c\u5b87\u6176, \u667a\u5b50", "creatorNameLang": "ja"}]}, {"creatorNames": [{"creatorName": "Katsura, Kosho", "creatorNameLang": "en"}]}, {"creatorNames": [{"creatorName": "Takushi, Yasuko", "creatorNameLang": "en"}]}, {"creatorNames": [{"creatorName": "Sakihara, Chizuko", "creatorNameLang": "en"}]}, {"creatorNames": [{"creatorName": "Nashiro, Takako", "creatorNameLang": "en"}]}, {"creatorNames": [{"creatorName": "Wauke, Tomoko", "creatorNameLang": "en"}]}]}, "item_1617186476635": {"attribute_name": "Access Rights", "attribute_value_mlt": [{"subitem_1522299639480": "open access", "subitem_1600958577026": "http://purl.org/coar/access_right/c_abf2"}]}, "item_1617186626617": {"attribute_name": "Description", "attribute_value_mlt": [{"subitem_description": "The continuous liquid-liquid extraction apparatus was newly designed and applied to recover and concentrate copper and cadmium from dilute aqueous solution. The batch extraction was also studied whether copper and cadmium were efficiently extracted into organic phase with some extractants like Na-diethyldithiocarbamate, tetraphenylarsonium chloride and pyridine. From the results, more than 95% of metal ions were extracted into organic phase, thus we could be able to apply to the continuous extraction. The volume of 250-500 ml. of solution containing 1-10 x 10^\u003c-4\u003eM metal ion was used as a sample of the continuous extraction and the recovery was about 80%.", "subitem_description_type": "Other"}, {"subitem_description": "\u7d00\u8981\u8ad6\u6587", "subitem_description_type": "Other"}]}, "item_1617186643794": {"attribute_name": "Publisher", "attribute_value_mlt": [{"subitem_1522300295150": "ja", "subitem_1522300316516": "\u7409\u7403\u5927\u5b66\u7406\u5de5\u5b66\u90e8"}, {"subitem_1522300295150": "en", "subitem_1522300316516": "Science and Engineering Division, University of the Ryukyus"}]}, "item_1617186702042": {"attribute_name": "Language", "attribute_value_mlt": [{"subitem_1551255818386": "jpn"}]}, "item_1617186783814": {"attribute_name": "Identifier", "attribute_value_mlt": [{"subitem_identifier_type": "HDL", "subitem_identifier_uri": "http://hdl.handle.net/20.500.12000/23708"}]}, "item_1617186920753": {"attribute_name": "Source Identifier", "attribute_value_mlt": [{"subitem_1522646500366": "NCID", "subitem_1522646572813": "AN0025080X"}]}, "item_1617186941041": {"attribute_name": "Source Title", "attribute_value_mlt": [{"subitem_1522650068558": "ja", "subitem_1522650091861": "\u7409\u7403\u5927\u5b66\u7406\u5de5\u5b66\u90e8\u7d00\u8981. \u7406\u5b66\u7de8"}, {"subitem_1522650068558": "en", "subitem_1522650091861": "Bulletin of Science \u0026 Engineering Division, University of Ryukyus. Mathematics \u0026 natural sciences"}]}, "item_1617187056579": {"attribute_name": "Bibliographic Information", "attribute_value_mlt": [{"bibliographicIssueNumber": "27", "bibliographicPageEnd": "75", "bibliographicPageStart": "69"}]}, "item_1617258105262": {"attribute_name": "Resource Type", "attribute_value_mlt": [{"resourcetype": "departmental bulletin paper", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_1617265215918": {"attribute_name": "Version Type", "attribute_value_mlt": [{"subitem_1522305645492": "NA", "subitem_1600292170262": "http://purl.org/coar/version/c_be7fb7dd8ff6fe43"}]}, "item_1617605131499": {"attribute_name": "File", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_access", "download_preview_message": "", "file_order": 0, "filename": "No27p069.pdf", "future_date_message": "", "is_thumbnail": false, "mimetype": "", "size": 0, "url": {"objectType": "fulltext", "url": "https://u-ryukyu.repo.nii.ac.jp/record/2007013/files/No27p069.pdf"}, "version_id": "f511b676-aa29-45f4-a441-1b6e73d77a96"}]}, "item_title": "\u9285\u3068\u30ab\u30c9\u30df\u30a6\u30e0\u306e\u6db2\u30fb\u6db2\u6eb6\u5a92\u62bd\u51fa\uff0d\u9023\u7d9a\u62bd\u51fa\u6cd5\u306e\u9069\u7528\uff0d", "item_type_id": "15", "owner": "1", "path": ["1642838003490", "1642838406414"], "permalink_uri": "http://hdl.handle.net/20.500.12000/23708", "pubdate": {"attribute_name": "PubDate", "attribute_value": "2012-03-06"}, "publish_date": "2012-03-06", "publish_status": "0", "recid": "2007013", "relation": {}, "relation_version_is_last": true, "title": ["\u9285\u3068\u30ab\u30c9\u30df\u30a6\u30e0\u306e\u6db2\u30fb\u6db2\u6eb6\u5a92\u62bd\u51fa\uff0d\u9023\u7d9a\u62bd\u51fa\u6cd5\u306e\u9069\u7528\uff0d"], "weko_shared_id": -1}
  1. 紀要論文
  2. 琉球大学理工学部紀要 理学編
  3. 27号
  1. 部局別インデックス
  2. 理学部

銅とカドミウムの液・液溶媒抽出-連続抽出法の適用-

http://hdl.handle.net/20.500.12000/23708
http://hdl.handle.net/20.500.12000/23708
2c908672-625c-4572-a8d7-5bb1a10218d2
名前 / ファイル ライセンス アクション
No27p069.pdf No27p069.pdf
Item type デフォルトアイテムタイプ(フル)(1)
公開日 2012-03-06
タイトル
タイトル 銅とカドミウムの液・液溶媒抽出-連続抽出法の適用-
言語 ja
作成者 桂, 幸昭

× 桂, 幸昭

ja 桂, 幸昭

沢岻, 康子

× 沢岻, 康子

ja 沢岻, 康子

崎原, 千鶴子

× 崎原, 千鶴子

ja 崎原, 千鶴子

名城, 孝子

× 名城, 孝子

ja 名城, 孝子

和宇慶, 智子

× 和宇慶, 智子

ja 和宇慶, 智子

Katsura, Kosho

× Katsura, Kosho

en Katsura, Kosho

Takushi, Yasuko

× Takushi, Yasuko

en Takushi, Yasuko

Sakihara, Chizuko

× Sakihara, Chizuko

en Sakihara, Chizuko

Nashiro, Takako

× Nashiro, Takako

en Nashiro, Takako

Wauke, Tomoko

× Wauke, Tomoko

en Wauke, Tomoko

アクセス権
アクセス権 open access
アクセス権URI http://purl.org/coar/access_right/c_abf2
内容記述
内容記述タイプ Other
内容記述 The continuous liquid-liquid extraction apparatus was newly designed and applied to recover and concentrate copper and cadmium from dilute aqueous solution. The batch extraction was also studied whether copper and cadmium were efficiently extracted into organic phase with some extractants like Na-diethyldithiocarbamate, tetraphenylarsonium chloride and pyridine. From the results, more than 95% of metal ions were extracted into organic phase, thus we could be able to apply to the continuous extraction. The volume of 250-500 ml. of solution containing 1-10 x 10^<-4>M metal ion was used as a sample of the continuous extraction and the recovery was about 80%.
内容記述タイプ Other
内容記述 紀要論文
出版者
言語 ja
出版者 琉球大学理工学部
言語
言語 jpn
資源タイプ
資源タイプ departmental bulletin paper
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
出版タイプ
出版タイプ NA
出版タイプResource http://purl.org/coar/version/c_be7fb7dd8ff6fe43
識別子
識別子 http://hdl.handle.net/20.500.12000/23708
識別子タイプ HDL
収録物識別子
収録物識別子タイプ NCID
収録物識別子 AN0025080X
収録物名
言語 ja
収録物名 琉球大学理工学部紀要. 理学編
書誌情報
号 27, p. 69-75
戻る
0
views
See details
Views

Versions

Ver.1 2022-01-28 04:10:15.968403
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON

確認


Powered by WEKO3


Powered by WEKO3