{"_buckets": {"deposit": "8606dc49-8806-4d3b-aefd-ce0519c58523"}, "_deposit": {"id": "2007197", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "2007197"}, "status": "published"}, "_oai": {"id": "oai:u-ryukyu.repo.nii.ac.jp:02007197", "sets": ["1642837724616", "1642838406845"]}, "author_link": [], "item_1617186331708": {"attribute_name": "Title", "attribute_value_mlt": [{"subitem_1551255647225": "Cavitation Characteristics for Hydrofoil\u3000Section with Pressure Water Supply", "subitem_1551255648112": "ja"}]}, "item_1617186419668": {"attribute_name": "Creator", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Maeda, Gisai", "creatorNameLang": "en"}]}, {"creatorNames": [{"creatorName": "\u771f\u6804\u7530, \u7fa9\u624d", "creatorNameLang": "ja"}]}]}, "item_1617186476635": {"attribute_name": "Access Rights", "attribute_value_mlt": [{"subitem_1522299639480": "open access", "subitem_1600958577026": "http://purl.org/coar/access_right/c_abf2"}]}, "item_1617186626617": {"attribute_name": "Description", "attribute_value_mlt": [{"subitem_description": "The paper describes some experimental investigations of cavitation characteristics of two dimensional hydro-foil section with pressure water supply from on its surface. The same kind of experiments were made and reported already by the author. Here again the same problem will be discussed. But the location and the direction of the supplied water flow are different largely from the previous, i.e., the location is about 23% of chord length from leading edge of the foil. and the direction is 47 degrees to the chord measuring from down stream side. Experimental results show that incipient cavitation parameter is somewhat larger when pressure water is supplied, but cavitation does not develop so fast as for none water supply. Further more, the effects of supplied water at the large angle of attack are different from the small angle.", "subitem_description_type": "Other"}, {"subitem_description": "\u7d00\u8981\u8ad6\u6587", "subitem_description_type": "Other"}]}, "item_1617186643794": {"attribute_name": "Publisher", "attribute_value_mlt": [{"subitem_1522300295150": "ja", "subitem_1522300316516": "\u7409\u7403\u5927\u5b66\u7406\u5de5\u5b66\u90e8"}, {"subitem_1522300295150": "en", "subitem_1522300316516": "Science and Engineering Division, University of the Ryukyus"}]}, "item_1617186702042": {"attribute_name": "Language", "attribute_value_mlt": [{"subitem_1551255818386": "eng"}]}, "item_1617186783814": {"attribute_name": "Identifier", "attribute_value_mlt": [{"subitem_identifier_type": "HDL", "subitem_identifier_uri": "http://hdl.handle.net/20.500.12000/24963"}]}, "item_1617186920753": {"attribute_name": "Source Identifier", "attribute_value_mlt": [{"subitem_1522646500366": "ISSN", "subitem_1522646572813": "0387-429X"}, {"subitem_1522646500366": "NCID", "subitem_1522646572813": "AN00250785"}]}, "item_1617186941041": {"attribute_name": "Source Title", "attribute_value_mlt": [{"subitem_1522650068558": "ja", "subitem_1522650091861": "\u7409\u7403\u5927\u5b66\u7406\u5de5\u5b66\u90e8\u7d00\u8981. \u5de5\u5b66\u7bc7"}, {"subitem_1522650068558": "en", "subitem_1522650091861": "Bulletin of Science \u0026 Engineering Division, University of the Ryukyus. Engineering"}]}, "item_1617187056579": {"attribute_name": "Bibliographic Information", "attribute_value_mlt": [{"bibliographicIssueNumber": "6", "bibliographicPageEnd": "63", "bibliographicPageStart": "51"}]}, "item_1617258105262": {"attribute_name": "Resource Type", "attribute_value_mlt": [{"resourcetype": "departmental bulletin paper", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_1617265215918": {"attribute_name": "Version Type", "attribute_value_mlt": [{"subitem_1522305645492": "VoR", "subitem_1600292170262": "http://purl.org/coar/version/c_970fb48d4fbd8a85"}]}, "item_1617605131499": {"attribute_name": "File", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_access", "download_preview_message": "", "file_order": 0, "filename": "NO6P051.pdf", "future_date_message": "", "is_thumbnail": false, "mimetype": "", "size": 0, "url": {"objectType": "fulltext", "url": "https://u-ryukyu.repo.nii.ac.jp/record/2007197/files/NO6P051.pdf"}, "version_id": "a91d8ab1-9b26-4244-b0e7-971981dfc12f"}]}, "item_title": "Cavitation Characteristics for Hydrofoil\u3000Section with Pressure Water Supply", "item_type_id": "15", "owner": "1", "path": ["1642837724616", "1642838406845"], "permalink_uri": "http://hdl.handle.net/20.500.12000/24963", "pubdate": {"attribute_name": "PubDate", "attribute_value": "2012-07-13"}, "publish_date": "2012-07-13", "publish_status": "0", "recid": "2007197", "relation": {}, "relation_version_is_last": true, "title": ["Cavitation Characteristics for Hydrofoil\u3000Section with Pressure Water Supply"], "weko_shared_id": -1}
  1. 紀要論文
  2. 琉球大学理工学部紀要 工学編
  3. 6号
  1. 部局別インデックス
  2. 工学部

Cavitation Characteristics for Hydrofoil Section with Pressure Water Supply

http://hdl.handle.net/20.500.12000/24963
http://hdl.handle.net/20.500.12000/24963
63dcfda9-9e63-403a-9ef0-dcabc262c866
名前 / ファイル ライセンス アクション
NO6P051.pdf NO6P051.pdf
Item type デフォルトアイテムタイプ(フル)(1)
公開日 2012-07-13
タイトル
タイトル Cavitation Characteristics for Hydrofoil Section with Pressure Water Supply
言語 ja
作成者 Maeda, Gisai

× Maeda, Gisai

en Maeda, Gisai

真栄田, 義才

× 真栄田, 義才

ja 真栄田, 義才

アクセス権
アクセス権 open access
アクセス権URI http://purl.org/coar/access_right/c_abf2
内容記述
内容記述タイプ Other
内容記述 The paper describes some experimental investigations of cavitation characteristics of two dimensional hydro-foil section with pressure water supply from on its surface. The same kind of experiments were made and reported already by the author. Here again the same problem will be discussed. But the location and the direction of the supplied water flow are different largely from the previous, i.e., the location is about 23% of chord length from leading edge of the foil. and the direction is 47 degrees to the chord measuring from down stream side. Experimental results show that incipient cavitation parameter is somewhat larger when pressure water is supplied, but cavitation does not develop so fast as for none water supply. Further more, the effects of supplied water at the large angle of attack are different from the small angle.
内容記述タイプ Other
内容記述 紀要論文
出版者
言語 ja
出版者 琉球大学理工学部
言語
言語 eng
資源タイプ
資源タイプ departmental bulletin paper
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
出版タイプ
出版タイプ VoR
出版タイプResource http://purl.org/coar/version/c_970fb48d4fbd8a85
識別子
識別子 http://hdl.handle.net/20.500.12000/24963
識別子タイプ HDL
収録物識別子
収録物識別子タイプ ISSN
収録物識別子 0387-429X
収録物識別子タイプ NCID
収録物識別子 AN00250785
収録物名
言語 ja
収録物名 琉球大学理工学部紀要. 工学篇
書誌情報
号 6, p. 51-63
戻る
0
views
See details
Views

Versions

Ver.1 2022-01-28 04:15:23.469549
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON

確認


Powered by WEKO3


Powered by WEKO3