ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

{"_buckets": {"deposit": "08809ac9-da68-450d-876c-172932819535"}, "_deposit": {"created_by": 8, "id": "2019569", "owner": "8", "owners": [8], "owners_ext": {"displayname": "ryukyu_lib", "username": null}, "pid": {"revision_id": 0, "type": "depid", "value": "2019569"}, "status": "published"}, "_oai": {"id": "oai:u-ryukyu.repo.nii.ac.jp:02019569", "sets": ["1669686986892", "1642838412624"]}, "author_link": [], "control_number": "2019569", "item_1617186331708": {"attribute_name": "Title", "attribute_value_mlt": [{"subitem_1551255647225": "\u9ad8\u9f62\u5fc3\u75be\u60a3\u60a3\u8005\u306b\u304a\u3051\u308b\u30d5\u30ec\u30a4\u30eb\u8a3a\u65ad\u6307\u6a19\u3068\u3057\u3066\u306e SPPB \u306e\u59a5\u5f53\u6027\u306e\u8a55\u4fa1", "subitem_1551255648112": "ja"}, {"subitem_1551255647225": "Validation of SPPB as a diagnostic tool for frailty in elderly patients with cardiovascular disease.", "subitem_1551255648112": "en"}]}, "item_1617186419668": {"attribute_name": "Creator", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "\u7389\u57ce, \u6c99\u767e\u5408", "creatorNameLang": "ja"}, {"creatorName": "Tamashiro, Sayuri", "creatorNameLang": "en"}]}, {"creatorNames": [{"creatorName": "\u5bae\u57ce, \u512a\u83dc", "creatorNameLang": "ja"}, {"creatorName": "Miyagi, Yuna", "creatorNameLang": "en"}]}, {"creatorNames": [{"creatorName": "\u559c\u7d0d, \u6d69\u53f8", "creatorNameLang": "ja"}, {"creatorName": "Kina, Koji", "creatorNameLang": "en"}]}, {"creatorNames": [{"creatorName": "\u4e2d\u672c, \u8056", "creatorNameLang": "ja"}, {"creatorName": "Nakamoto, Satoru", "creatorNameLang": "en"}]}, {"creatorNames": [{"creatorName": "\u65b0\u5730, \u660e\u9999", "creatorNameLang": "ja"}, {"creatorName": "Miiji, Asuka", "creatorNameLang": "en"}]}, {"creatorNames": [{"creatorName": "\u4e95\u4e0a, \u5353", "creatorNameLang": "ja"}, {"creatorName": "Inoue, Taku", "creatorNameLang": "en"}]}, {"creatorNames": [{"creatorName": "\u65b0\u57ce, \u54f2\u6cbb", "creatorNameLang": "ja"}, {"creatorName": "Shinjo, Tetsuji", "creatorNameLang": "en"}]}]}, "item_1617186476635": {"attribute_name": "Access Rights", "attribute_value_mlt": [{"subitem_1522299639480": "open access", "subitem_1600958577026": "http://purl.org/coar/access_right/c_abf2"}]}, "item_1617186499011": {"attribute_name": "Rights", "attribute_value_mlt": [{"subitem_1522650717957": "ja", "subitem_1522651041219": "\u7409\u7403\u533b\u5b66\u4f1a"}]}, "item_1617186609386": {"attribute_name": "Subject", "attribute_value_mlt": [{"subitem_1522299896455": "en", "subitem_1522300014469": "Other", "subitem_1523261968819": "SPPB"}, {"subitem_1522299896455": "en", "subitem_1522300014469": "Other", "subitem_1523261968819": "frailty"}, {"subitem_1522299896455": "en", "subitem_1522300014469": "Other", "subitem_1523261968819": "elderly"}, {"subitem_1522299896455": "en", "subitem_1522300014469": "Other", "subitem_1523261968819": "cardiovascular disease"}]}, "item_1617186626617": {"attribute_name": "Description", "attribute_value_mlt": [{"subitem_description": "The Short Physical Performance Battery (SPPB) is an objective assessment tool for evaluating lower extremity function in older people associated with reduced activities of daily living, nursing home admission, and mortality. Its applicability in the clinical setting, however, is limited due to a ceiling effect in the general population. Older patients with cardiovascular disease (CVD) are likely to have reduced muscle strength, exercise tolerance, and balance ability, as well as a higher falling risk and prevalent frailty. Appropriate evaluation and intervention for these issues are required to promote a healthy life expectancy in these patients. We tested the validity of the SPPB for evaluating physical function and the applicability of the SPPB as a diagnostic tool for frailty in older patients with CVD. A total of 47 patients (age 74 [67-82] years, 62% male, 28% frailty) were evaluated in an outpatient setting. SPPB scores were significantly associated with scores for the hand grip strength, 6-min walk test, one-legged stance test, and time up and go test, even after adjusting for confounding factors. Assuming an SPPB score cutoff value of 9, the sensitivity was 61.5% and the specificity was 90.6% (AUCROC 0.81). The SPPB is a simple physical measurement applicable as a diagnostic tool for frailty in elderly patients with CVD in the outpatient setting.", "subitem_description_language": "en", "subitem_description_type": "Abstract"}]}, "item_1617186643794": {"attribute_name": "Publisher", "attribute_value_mlt": [{"subitem_1522300295150": "ja", "subitem_1522300316516": "\u7409\u7403\u533b\u5b66\u4f1a"}]}, "item_1617186702042": {"attribute_name": "Language", "attribute_value_mlt": [{"subitem_1551255818386": "jpn"}]}, "item_1617186920753": {"attribute_name": "Source Identifier", "attribute_value_mlt": [{"subitem_1522646500366": "EISSN", "subitem_1522646572813": "1346-888X"}, {"subitem_1522646500366": "NCID", "subitem_1522646572813": "AN10369445"}]}, "item_1617186941041": {"attribute_name": "Source Title", "attribute_value_mlt": [{"subitem_1522650068558": "ja", "subitem_1522650091861": "\u7409\u7403\u533b\u5b66\u4f1a\u8a8c = Ryukyu Medical Journal"}]}, "item_1617187056579": {"attribute_name": "Bibliographic Information", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2021-10", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "1-4", "bibliographicPageEnd": "8", "bibliographicPageStart": "1", "bibliographicVolumeNumber": "40"}]}, "item_1617258105262": {"attribute_name": "Resource Type", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_1617265215918": {"attribute_name": "Version Type", "attribute_value_mlt": [{"subitem_1522305645492": "VoR", "subitem_1600292170262": "http://purl.org/coar/version/c_970fb48d4fbd8a85"}]}, "item_1617605131499": {"attribute_name": "File", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_access", "date": [{"dateType": "Available", "dateValue": "2022-11-30"}], "download_preview_message": "", "file_order": 0, "filename": "Vol40p1.pdf", "filesize": [{"value": "466 KB"}], "future_date_message": "", "is_thumbnail": false, "mimetype": "", "size": 466000.0, "url": {"objectType": "fulltext", "url": "https://u-ryukyu.repo.nii.ac.jp/record/2019569/files/Vol40p1.pdf"}, "version_id": "95bbd75c-9142-4417-8617-b38519f7cf36"}]}, "item_title": "\u9ad8\u9f62\u5fc3\u75be\u60a3\u60a3\u8005\u306b\u304a\u3051\u308b\u30d5\u30ec\u30a4\u30eb\u8a3a\u65ad\u6307\u6a19\u3068\u3057\u3066\u306e SPPB \u306e\u59a5\u5f53\u6027\u306e\u8a55\u4fa1", "item_type_id": "59", "owner": "8", "path": ["1669686986892", "1642838412624"], "permalink_uri": "http://hdl.handle.net/20.500.12000/0002019569", "pubdate": {"attribute_name": "PubDate", "attribute_value": "2022-11-30"}, "publish_date": "2022-11-30", "publish_status": "0", "recid": "2019569", "relation": {}, "relation_version_is_last": true, "title": ["\u9ad8\u9f62\u5fc3\u75be\u60a3\u60a3\u8005\u306b\u304a\u3051\u308b\u30d5\u30ec\u30a4\u30eb\u8a3a\u65ad\u6307\u6a19\u3068\u3057\u3066\u306e SPPB \u306e\u59a5\u5f53\u6027\u306e\u8a55\u4fa1"], "weko_shared_id": -1}
  1. 学術雑誌論文
  2. 琉球医学会
  3. 琉球医学会誌
  4. 40巻1-4号
  1. 部局別インデックス
  2. その他

高齢心疾患患者におけるフレイル診断指標としての SPPB の妥当性の評価

http://hdl.handle.net/20.500.12000/0002019569
http://hdl.handle.net/20.500.12000/0002019569
d580f17d-2768-40c1-bfad-5d2e2af54bc4
名前 / ファイル ライセンス アクション
Vol40p1.pdf Vol40p1.pdf (466 KB)
Item type 琉球大学リポジトリ登録用アイテムタイプ(1)
公開日 2022-11-30
タイトル
タイトル 高齢心疾患患者におけるフレイル診断指標としての SPPB の妥当性の評価
言語 ja
作成者 玉城, 沙百合

× 玉城, 沙百合

ja 玉城, 沙百合

en Tamashiro, Sayuri

宮城, 優菜

× 宮城, 優菜

ja 宮城, 優菜

en Miyagi, Yuna

喜納, 浩司

× 喜納, 浩司

ja 喜納, 浩司

en Kina, Koji

中本, 聖

× 中本, 聖

ja 中本, 聖

en Nakamoto, Satoru

新地, 明香

× 新地, 明香

ja 新地, 明香

en Miiji, Asuka

井上, 卓

× 井上, 卓

ja 井上, 卓

en Inoue, Taku

新城, 哲治

× 新城, 哲治

ja 新城, 哲治

en Shinjo, Tetsuji

アクセス権
アクセス権 open access
アクセス権URI http://purl.org/coar/access_right/c_abf2
権利情報
言語 ja
権利情報 琉球医学会
主題
言語 en
主題Scheme Other
主題 SPPB
言語 en
主題Scheme Other
主題 frailty
言語 en
主題Scheme Other
主題 elderly
言語 en
主題Scheme Other
主題 cardiovascular disease
内容記述
内容記述タイプ Abstract
内容記述 The Short Physical Performance Battery (SPPB) is an objective assessment tool for evaluating lower extremity function in older people associated with reduced activities of daily living, nursing home admission, and mortality. Its applicability in the clinical setting, however, is limited due to a ceiling effect in the general population. Older patients with cardiovascular disease (CVD) are likely to have reduced muscle strength, exercise tolerance, and balance ability, as well as a higher falling risk and prevalent frailty. Appropriate evaluation and intervention for these issues are required to promote a healthy life expectancy in these patients. We tested the validity of the SPPB for evaluating physical function and the applicability of the SPPB as a diagnostic tool for frailty in older patients with CVD. A total of 47 patients (age 74 [67-82] years, 62% male, 28% frailty) were evaluated in an outpatient setting. SPPB scores were significantly associated with scores for the hand grip strength, 6-min walk test, one-legged stance test, and time up and go test, even after adjusting for confounding factors. Assuming an SPPB score cutoff value of 9, the sensitivity was 61.5% and the specificity was 90.6% (AUCROC 0.81). The SPPB is a simple physical measurement applicable as a diagnostic tool for frailty in elderly patients with CVD in the outpatient setting.
言語 en
出版者
言語 ja
出版者 琉球医学会
言語
言語 jpn
資源タイプ
資源タイプ journal article
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
出版タイプ
出版タイプ VoR
出版タイプResource http://purl.org/coar/version/c_970fb48d4fbd8a85
収録物識別子
収録物識別子タイプ EISSN
収録物識別子 1346-888X
収録物識別子タイプ NCID
収録物識別子 AN10369445
収録物名
言語 ja
収録物名 琉球医学会誌 = Ryukyu Medical Journal
書誌情報
巻 40, 号 1-4, p. 1-8, 発行日 2021-10
戻る
0
views
See details
Views

Versions

Ver.1 2022-11-30 06:21:07.553418
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON

確認


Powered by WEKO3


Powered by WEKO3