{"_buckets": {"deposit": "1a9cc3d4-544a-4a2d-9baa-d5bfcea643f1"}, "_deposit": {"id": "2000811", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "2000811"}, "status": "published"}, "_oai": {"id": "oai:u-ryukyu.repo.nii.ac.jp:02000811", "sets": ["1642838338003", "1642838406845"]}, "author_link": [], "item_1617186331708": {"attribute_name": "Title", "attribute_value_mlt": [{"subitem_1551255647225": "平行平板流路内に千鳥状に円柱を置いた場合の壁面熱伝達", "subitem_1551255648112": "ja"}, {"subitem_1551255647225": "Heat Transfer in a Parallel Plate Duct with Circular Cylinders Placed Staggered", "subitem_1551255648112": "en"}]}, "item_1617186419668": {"attribute_name": "Creator", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "親川, 兼勇", "creatorNameLang": "ja"}]}, {"creatorNames": [{"creatorName": "馬渕, 幾夫", "creatorNameLang": "ja"}]}, {"creatorNames": [{"creatorName": "Oyakawa, Kenyu", "creatorNameLang": "en"}]}, {"creatorNames": [{"creatorName": "Mabuchi, Ikuo", "creatorNameLang": "en"}]}]}, "item_1617186476635": {"attribute_name": "Access Rights", "attribute_value_mlt": [{"subitem_1522299639480": "open access", "subitem_1600958577026": "http://purl.org/coar/access_right/c_abf2"}]}, "item_1617186499011": {"attribute_name": "Rights", "attribute_value_mlt": [{"subitem_1522650717957": "ja", "subitem_1522651041219": "Copyright (c) 1982 日本機械学会"}]}, "item_1617186609386": {"attribute_name": "Subject", "attribute_value_mlt": [{"subitem_1522299896455": "en", "subitem_1522300014469": "Other", "subitem_1523261968819": "Convective Heat Transfer"}, {"subitem_1522299896455": "en", "subitem_1522300014469": "Other", "subitem_1523261968819": "Heat Transfer Augmentation"}, {"subitem_1522299896455": "en", "subitem_1522300014469": "Other", "subitem_1523261968819": "Turbulence Promoter"}, {"subitem_1522299896455": "en", "subitem_1522300014469": "Other", "subitem_1523261968819": "Pressure Loss"}, {"subitem_1522299896455": "en", "subitem_1522300014469": "Other", "subitem_1523261968819": "Parallel Plate Duct"}, {"subitem_1522299896455": "en", "subitem_1522300014469": "Other", "subitem_1523261968819": "Karman Vortex"}, {"subitem_1522299896455": "en", "subitem_1522300014469": "Other", "subitem_1523261968819": "Reattachment"}]}, "item_1617186626617": {"attribute_name": "Description", "attribute_value_mlt": [{"subitem_description": "強制対流場での伝熱促進を計るため, 平行平板流路に円柱列(ブロッケージ比0.4)を千鳥状にそう入した場合, 局所熱伝達特性に対するピッチ比Pおよび管軸中心からの円柱オフセット量Hの影響を実験的に調べた. 局所熱伝達率分布はうず放出の有無に支配される円柱後流のフローパターンに依存することを明らかにするとともに, 伝熱促進機構について考察した. また圧力損失を考慮した熱的性能比についても検討した.", "subitem_description_type": "Other"}, {"subitem_description": "論文", "subitem_description_type": "Other"}]}, "item_1617186643794": {"attribute_name": "Publisher", "attribute_value_mlt": [{"subitem_1522300295150": "ja", "subitem_1522300316516": "日本機械学会"}]}, "item_1617186702042": {"attribute_name": "Language", "attribute_value_mlt": [{"subitem_1551255818386": "jpn"}]}, "item_1617186783814": {"attribute_name": "Identifier", "attribute_value_mlt": [{"subitem_identifier_type": "HDL", "subitem_identifier_uri": "http://hdl.handle.net/20.500.12000/199"}]}, "item_1617186920753": {"attribute_name": "Source Identifier", "attribute_value_mlt": [{"subitem_1522646500366": "ISSN", "subitem_1522646572813": "03875016"}, {"subitem_1522646500366": "NCID", "subitem_1522646572813": "AN00187441"}]}, "item_1617186941041": {"attribute_name": "Source Title", "attribute_value_mlt": [{"subitem_1522650068558": "ja", "subitem_1522650091861": "日本機械学会論文集. B編"}, {"subitem_1522650068558": "en", "subitem_1522650091861": "Transactions of the Japan Society of Mechanical Engineers. B"}]}, "item_1617187056579": {"attribute_name": "Bibliographic Information", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "1982-08-25", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "432", "bibliographicPageEnd": "1519", "bibliographicPageStart": "1509", "bibliographicVolumeNumber": "48"}]}, "item_1617258105262": {"attribute_name": "Resource Type", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_1617265215918": {"attribute_name": "Version Type", "attribute_value_mlt": [{"subitem_1522305645492": "VoR", "subitem_1600292170262": "http://purl.org/coar/version/c_970fb48d4fbd8a85"}]}, "item_1617605131499": {"attribute_name": "File", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_access", "download_preview_message": "", "file_order": 0, "filename": "oyakawa_k05.pdf", "future_date_message": "", "is_thumbnail": false, "mimetype": "", "size": 0, "url": {"objectType": "fulltext", "url": "https://u-ryukyu.repo.nii.ac.jp/record/2000811/files/oyakawa_k05.pdf"}, "version_id": "c6c2a30a-4cf4-4ced-8d20-d428cdb0e737"}]}, "item_title": "平行平板流路内に千鳥状に円柱を置いた場合の壁面熱伝達", "item_type_id": "15", "owner": "1", "path": ["1642838338003", "1642838406845"], "permalink_uri": "http://hdl.handle.net/20.500.12000/199", "pubdate": {"attribute_name": "PubDate", "attribute_value": "2007-03-04"}, "publish_date": "2007-03-04", "publish_status": "0", "recid": "2000811", "relation": {}, "relation_version_is_last": true, "title": ["平行平板流路内に千鳥状に円柱を置いた場合の壁面熱伝達"], "weko_shared_id": -1}
平行平板流路内に千鳥状に円柱を置いた場合の壁面熱伝達
http://hdl.handle.net/20.500.12000/199
http://hdl.handle.net/20.500.12000/199