ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学術雑誌論文
  2. その他
  1. 部局別インデックス
  2. 工学部

An adaptive dead-time compensation strategy for voltage source inverter fed motor drives

http://hdl.handle.net/20.500.12000/4630
http://hdl.handle.net/20.500.12000/4630
bb3a5951-7fe1-4686-9243-bdfcafdc2875
名前 / ファイル ライセンス アクション
IEEE_PE_v20n5_1150.pdf IEEE_PE_v20n5_1150.pdf
Item type デフォルトアイテムタイプ(フル)(1)
公開日 2008-02-18
タイトル
タイトル An adaptive dead-time compensation strategy for voltage source inverter fed motor drives
言語 en
作成者 Urasaki, Naomitsu

× Urasaki, Naomitsu

en Urasaki, Naomitsu

Search repository
Senjyu, Tomonobu

× Senjyu, Tomonobu

en Senjyu, Tomonobu

Search repository
Uezato, Katsumi

× Uezato, Katsumi

en Uezato, Katsumi

Search repository
Funabashi, Toshihisa

× Funabashi, Toshihisa

en Funabashi, Toshihisa

Search repository
浦崎, 直光

× 浦崎, 直光

ja 浦崎, 直光

Search repository
千住, 智信

× 千住, 智信

ja 千住, 智信

Search repository
上里, 勝實

× 上里, 勝實

ja 上里, 勝實

Search repository
アクセス権
アクセス権 open access
アクセス権URI http://purl.org/coar/access_right/c_abf2
権利情報
言語 en
権利情報 (C)2005 IEEE. Personal use of this material is permitted. However, permission to reprint/republish this material for advertising or promotional purposes or for creating new collective works for resale or redistribution to servers or lists, or to reuse any copyrighted component of this work in other works must be obtained from the IEEE.
主題
言語 en
主題Scheme Other
主題 current vector
主題
言語 en
主題Scheme Other
主題 dead-time
主題
言語 en
主題Scheme Other
主題 disturbance observer
主題
言語 en
主題Scheme Other
主題 permanent magnet synchronous motor (PMSM)
主題
言語 en
主題Scheme Other
主題 voltage source inverter (VSI)
内容記述
内容記述タイプ Other
内容記述 This paper presents an adaptive dead-time compensation strategy to obtain fundamental phase voltage for inverter fed vector controlled permanent magnet synchronous motor drives. The amplitude of phase dead-time compensation voltage (DTCV) to compensate disturbance voltage due to undesirable characteristics of inverter, such as dead-time, turn-on/off time of switching devices, and on-voltages of switching devices and diodes is adaptively determined according to a dead-time compensation time (DTCT). DTCT is identified on-line with using a /spl delta/-axis disturbance voltage in the current reference frame that is synchronized with current vector. The /spl delta/-axis disturbance voltage is estimated by a disturbance observer. The accuracy of identified DTCT is experimentally confirmed by calculating the mean absolute percentage error (MAPE) between a calculated active power and a measured one. MAPE for adaptive DTCT is almost within 5% at any operating point.
内容記述
内容記述タイプ Other
内容記述 論文
出版者
出版者 IEEE Institute of Electrical and Electronics
言語 en
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
出版タイプ
出版タイプ VoR
出版タイプResource http://purl.org/coar/version/c_970fb48d4fbd8a85
識別子
識別子 http://hdl.handle.net/20.500.12000/4630
識別子タイプ HDL
関連情報
識別子タイプ URI
関連識別子 http://ieeexplore.ieee.org/xpl/RecentIssue.jsp?punumber=63
収録物識別子
収録物識別子タイプ ISSN
収録物識別子 0885-8993
収録物識別子
収録物識別子タイプ NCID
収録物識別子 AA10670151
収録物名
収録物名 IEEE Transactions on Power Electronics
言語 en
書誌情報
巻 20, 号 5, p. 1150-1160, 発行日 2005-09
戻る
0
views
See details
Views

Versions

Ver.1 2022-01-27 07:37:33.408977
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3