ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

{"_buckets": {"deposit": "00effef8-7a0e-443f-b16b-3d897c303356"}, "_deposit": {"id": "2007034", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "2007034"}, "status": "published"}, "_oai": {"id": "oai:u-ryukyu.repo.nii.ac.jp:02007034", "sets": ["1642837722903", "1642838406845"]}, "author_link": [], "item_1617186331708": {"attribute_name": "Title", "attribute_value_mlt": [{"subitem_1551255647225": "\u5668\u5177\u306e\u76f8\u9055\u306b\u3088\u308b\u6db2\u6027\u9650\u754c\u5024\u306e\u3061\u304c\u3044\u3068\u4e00\u70b9\u6cd5\u306e\u9069\u7528\u306b\u3064\u3044\u3066", "subitem_1551255648112": "ja"}, {"subitem_1551255647225": "Laboratory Studies of the Two Typical L.L Devices and the One-Point L.L.Method", "subitem_1551255648112": "en"}]}, "item_1617186419668": {"attribute_name": "Creator", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "\u4e0a\u539f, \u4e07\u6210", "creatorNameLang": "ja"}]}, {"creatorNames": [{"creatorName": "Uehara, Hosei", "creatorNameLang": "en"}]}]}, "item_1617186476635": {"attribute_name": "Access Rights", "attribute_value_mlt": [{"subitem_1522299639480": "open access", "subitem_1600958577026": "http://purl.org/coar/access_right/c_abf2"}]}, "item_1617186626617": {"attribute_name": "Description", "attribute_value_mlt": [{"subitem_description": "The liquid limit test is perhaps the oldest and most widely accepted of all the laboratory tests of soils.However,the devices and procedures employed by various countries and organizations differ.Consequently,the test results give different values.Also the imperfections of the devices and procedures naturally produce the experimental errors.For such problems,the investigations into the devices,procedures,short-cut methods,and new apparatus have been reported in various countries.\\nThis paper presents the liquid limit results from a Japanese device(JIStype) and an American device (ASTM type)for comparison ofthe values,and discusses the applicability of the one-point liquid limit method for the soils in Okinawa. It was found that the ASTM type device gives lower values than the JIS type device and the difference in terms of moisture content between both values is given by the equation,\u25b3\uff1d0.133\u3000L.L.I-1.018,where L.L is the JIS\\ntype value.The indices tan\u03b2 for the ASTM type device and for the JIS type device were found to be 0.130 and 0.098 respectively.For normal classification purposes these values gave the results well within the accuracy required in normal work.", "subitem_description_type": "Other"}, {"subitem_description": "\u7d00\u8981\u8ad6\u6587", "subitem_description_type": "Other"}]}, "item_1617186643794": {"attribute_name": "Publisher", "attribute_value_mlt": [{"subitem_1522300295150": "ja", "subitem_1522300316516": "\u7409\u7403\u5927\u5b66\u7406\u5de5\u5b66\u90e8"}, {"subitem_1522300295150": "en", "subitem_1522300316516": "Science and Engineering Division, University of the Ryukyus"}]}, "item_1617186702042": {"attribute_name": "Language", "attribute_value_mlt": [{"subitem_1551255818386": "jpn"}]}, "item_1617186783814": {"attribute_name": "Identifier", "attribute_value_mlt": [{"subitem_identifier_type": "HDL", "subitem_identifier_uri": "http://hdl.handle.net/20.500.12000/23830"}]}, "item_1617186920753": {"attribute_name": "Source Identifier", "attribute_value_mlt": [{"subitem_1522646500366": "ISSN", "subitem_1522646572813": "0387-429X"}, {"subitem_1522646500366": "NCID", "subitem_1522646572813": "AN00250785"}]}, "item_1617186941041": {"attribute_name": "Source Title", "attribute_value_mlt": [{"subitem_1522650068558": "ja", "subitem_1522650091861": "\u7409\u7403\u5927\u5b66\u7406\u5de5\u5b66\u90e8\u7d00\u8981 \u5de5\u5b66\u7bc7"}]}, "item_1617187056579": {"attribute_name": "Bibliographic Information", "attribute_value_mlt": [{"bibliographicIssueNumber": "2", "bibliographicPageEnd": "126", "bibliographicPageStart": "111"}]}, "item_1617258105262": {"attribute_name": "Resource Type", "attribute_value_mlt": [{"resourcetype": "departmental bulletin paper", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_1617265215918": {"attribute_name": "Version Type", "attribute_value_mlt": [{"subitem_1522305645492": "NA", "subitem_1600292170262": "http://purl.org/coar/version/c_be7fb7dd8ff6fe43"}]}, "item_1617605131499": {"attribute_name": "File", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_access", "download_preview_message": "", "file_order": 0, "filename": "NO2P111.pdf", "future_date_message": "", "is_thumbnail": false, "mimetype": "", "size": 0, "url": {"objectType": "fulltext", "url": "https://u-ryukyu.repo.nii.ac.jp/record/2007034/files/NO2P111.pdf"}, "version_id": "2cf49f94-05d6-401e-a3c0-63915db59584"}]}, "item_title": "\u5668\u5177\u306e\u76f8\u9055\u306b\u3088\u308b\u6db2\u6027\u9650\u754c\u5024\u306e\u3061\u304c\u3044\u3068\u4e00\u70b9\u6cd5\u306e\u9069\u7528\u306b\u3064\u3044\u3066", "item_type_id": "15", "owner": "1", "path": ["1642837722903", "1642838406845"], "permalink_uri": "http://hdl.handle.net/20.500.12000/23830", "pubdate": {"attribute_name": "PubDate", "attribute_value": "2012-03-19"}, "publish_date": "2012-03-19", "publish_status": "0", "recid": "2007034", "relation": {}, "relation_version_is_last": true, "title": ["\u5668\u5177\u306e\u76f8\u9055\u306b\u3088\u308b\u6db2\u6027\u9650\u754c\u5024\u306e\u3061\u304c\u3044\u3068\u4e00\u70b9\u6cd5\u306e\u9069\u7528\u306b\u3064\u3044\u3066"], "weko_shared_id": -1}
  1. 紀要論文
  2. 琉球大学理工学部紀要 工学編
  3. 2号
  1. 部局別インデックス
  2. 工学部

器具の相違による液性限界値のちがいと一点法の適用について

http://hdl.handle.net/20.500.12000/23830
http://hdl.handle.net/20.500.12000/23830
98fc7e98-ad4a-414f-9b49-9f748f2f7a93
名前 / ファイル ライセンス アクション
NO2P111.pdf NO2P111.pdf
Item type デフォルトアイテムタイプ(フル)(1)
公開日 2012-03-19
タイトル
タイトル 器具の相違による液性限界値のちがいと一点法の適用について
言語 ja
作成者 上原, 万成

× 上原, 万成

ja 上原, 万成

Uehara, Hosei

× Uehara, Hosei

en Uehara, Hosei

アクセス権
アクセス権 open access
アクセス権URI http://purl.org/coar/access_right/c_abf2
内容記述
内容記述タイプ Other
内容記述 The liquid limit test is perhaps the oldest and most widely accepted of all the laboratory tests of soils.However,the devices and procedures employed by various countries and organizations differ.Consequently,the test results give different values.Also the imperfections of the devices and procedures naturally produce the experimental errors.For such problems,the investigations into the devices,procedures,short-cut methods,and new apparatus have been reported in various countries.\nThis paper presents the liquid limit results from a Japanese device(JIStype) and an American device (ASTM type)for comparison ofthe values,and discusses the applicability of the one-point liquid limit method for the soils in Okinawa. It was found that the ASTM type device gives lower values than the JIS type device and the difference in terms of moisture content between both values is given by the equation,△=0.133 L.L.I-1.018,where L.L is the JIS\ntype value.The indices tanβ for the ASTM type device and for the JIS type device were found to be 0.130 and 0.098 respectively.For normal classification purposes these values gave the results well within the accuracy required in normal work.
内容記述タイプ Other
内容記述 紀要論文
出版者
言語 ja
出版者 琉球大学理工学部
言語
言語 jpn
資源タイプ
資源タイプ departmental bulletin paper
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
出版タイプ
出版タイプ NA
出版タイプResource http://purl.org/coar/version/c_be7fb7dd8ff6fe43
識別子
識別子 http://hdl.handle.net/20.500.12000/23830
識別子タイプ HDL
収録物識別子
収録物識別子タイプ ISSN
収録物識別子 0387-429X
収録物識別子タイプ NCID
収録物識別子 AN00250785
収録物名
言語 ja
収録物名 琉球大学理工学部紀要 工学篇
書誌情報
号 2, p. 111-126
戻る
0
views
See details
Views

Versions

Ver.1 2022-01-28 04:10:51.632587
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON

確認


Powered by WEKO3


Powered by WEKO3