ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

{"_buckets": {"deposit": "8b3f4ec8-2e84-4099-8111-ad7a945be88d"}, "_deposit": {"id": "2007196", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "2007196"}, "status": "published"}, "_oai": {"id": "oai:u-ryukyu.repo.nii.ac.jp:02007196", "sets": ["1642837724616", "1642838406845"]}, "author_link": [], "item_1617186331708": {"attribute_name": "Title", "attribute_value_mlt": [{"subitem_1551255647225": "Performance of Wide-Angle Two Dimensional Diffusers with Vane Systems (2nd Report)", "subitem_1551255648112": "en"}]}, "item_1617186419668": {"attribute_name": "Creator", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Yamazato, Eisho", "creatorNameLang": "en"}]}, {"creatorNames": [{"creatorName": "Irabu, Kunio", "creatorNameLang": "en"}]}, {"creatorNames": [{"creatorName": "\u5c71\u91cc, \u6804\u662d", "creatorNameLang": "ja"}]}, {"creatorNames": [{"creatorName": "\u4f0a\u826f\u90e8, \u90a6\u592b", "creatorNameLang": "ja"}]}]}, "item_1617186476635": {"attribute_name": "Access Rights", "attribute_value_mlt": [{"subitem_1522299639480": "open access", "subitem_1600958577026": "http://purl.org/coar/access_right/c_abf2"}]}, "item_1617186626617": {"attribute_name": "Description", "attribute_value_mlt": [{"subitem_description": "Experiments have been made with flat vanes in two-dimensional diffusers with divergence angles of 30\u00b0, 40\u00b0 and 60\u00b0 and an area ratio of 4:1, to determine the optimum vane\u3000location and the effect of vanes on the pressure recovery. The\u3000performance of these\u3000diffusers was improved by means of short flat vanes placed in the vicinity of the diffuser inlet section. The basic criteria for effective vane configurations with source-point translation were developed which indicated that the optimum pressure recovery was attained for both 30\u00b0and 40\u00b0 diffusers at \u25b3\u03b8=3\u00b0, the angle for measuring\u3000source-point translation. However the source-point translation did not bring any appreciable improvement in the\u3000performance for the 30\u00b0 diffuser.", "subitem_description_type": "Other"}, {"subitem_description": "\u7d00\u8981\u8ad6\u6587", "subitem_description_type": "Other"}]}, "item_1617186643794": {"attribute_name": "Publisher", "attribute_value_mlt": [{"subitem_1522300295150": "ja", "subitem_1522300316516": "\u7409\u7403\u5927\u5b66\u7406\u5de5\u5b66\u90e8"}, {"subitem_1522300295150": "en", "subitem_1522300316516": "Science and Engineering Division, University of the Ryukyus"}]}, "item_1617186702042": {"attribute_name": "Language", "attribute_value_mlt": [{"subitem_1551255818386": "eng"}]}, "item_1617186783814": {"attribute_name": "Identifier", "attribute_value_mlt": [{"subitem_identifier_type": "HDL", "subitem_identifier_uri": "http://hdl.handle.net/20.500.12000/24962"}]}, "item_1617186920753": {"attribute_name": "Source Identifier", "attribute_value_mlt": [{"subitem_1522646500366": "ISSN", "subitem_1522646572813": "0387-429X"}, {"subitem_1522646500366": "NCID", "subitem_1522646572813": "AN00250785"}]}, "item_1617186941041": {"attribute_name": "Source Title", "attribute_value_mlt": [{"subitem_1522650068558": "ja", "subitem_1522650091861": "\u7409\u7403\u5927\u5b66\u7406\u5de5\u5b66\u90e8\u7d00\u8981. \u5de5\u5b66\u7bc7"}, {"subitem_1522650068558": "en", "subitem_1522650091861": "Bulletin of Science \u0026 Engineering Division, University of the Ryukyus. Engineering"}]}, "item_1617187056579": {"attribute_name": "Bibliographic Information", "attribute_value_mlt": [{"bibliographicIssueNumber": "6", "bibliographicPageEnd": "50", "bibliographicPageStart": "39"}]}, "item_1617258105262": {"attribute_name": "Resource Type", "attribute_value_mlt": [{"resourcetype": "departmental bulletin paper", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_1617265215918": {"attribute_name": "Version Type", "attribute_value_mlt": [{"subitem_1522305645492": "VoR", "subitem_1600292170262": "http://purl.org/coar/version/c_970fb48d4fbd8a85"}]}, "item_1617605131499": {"attribute_name": "File", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_access", "download_preview_message": "", "file_order": 0, "filename": "NO6P039.pdf", "future_date_message": "", "is_thumbnail": false, "mimetype": "", "size": 0, "url": {"objectType": "fulltext", "url": "https://u-ryukyu.repo.nii.ac.jp/record/2007196/files/NO6P039.pdf"}, "version_id": "b4677288-2c00-4501-9054-15727cdfcb5a"}]}, "item_title": "Performance of Wide-Angle Two Dimensional Diffusers with Vane Systems (2nd Report)", "item_type_id": "15", "owner": "1", "path": ["1642837724616", "1642838406845"], "permalink_uri": "http://hdl.handle.net/20.500.12000/24962", "pubdate": {"attribute_name": "PubDate", "attribute_value": "2012-07-13"}, "publish_date": "2012-07-13", "publish_status": "0", "recid": "2007196", "relation": {}, "relation_version_is_last": true, "title": ["Performance of Wide-Angle Two Dimensional Diffusers with Vane Systems (2nd Report)"], "weko_shared_id": -1}
  1. 紀要論文
  2. 琉球大学理工学部紀要 工学編
  3. 6号
  1. 部局別インデックス
  2. 工学部

Performance of Wide-Angle Two Dimensional Diffusers with Vane Systems (2nd Report)

http://hdl.handle.net/20.500.12000/24962
http://hdl.handle.net/20.500.12000/24962
a3eda842-c3cb-447e-9c8f-08e08c948b99
名前 / ファイル ライセンス アクション
NO6P039.pdf NO6P039.pdf
Item type デフォルトアイテムタイプ(フル)(1)
公開日 2012-07-13
タイトル
タイトル Performance of Wide-Angle Two Dimensional Diffusers with Vane Systems (2nd Report)
言語 en
作成者 Yamazato, Eisho

× Yamazato, Eisho

en Yamazato, Eisho

Irabu, Kunio

× Irabu, Kunio

en Irabu, Kunio

山里, 栄昭

× 山里, 栄昭

ja 山里, 栄昭

伊良部, 邦夫

× 伊良部, 邦夫

ja 伊良部, 邦夫

アクセス権
アクセス権 open access
アクセス権URI http://purl.org/coar/access_right/c_abf2
内容記述
内容記述タイプ Other
内容記述 Experiments have been made with flat vanes in two-dimensional diffusers with divergence angles of 30°, 40° and 60° and an area ratio of 4:1, to determine the optimum vane location and the effect of vanes on the pressure recovery. The performance of these diffusers was improved by means of short flat vanes placed in the vicinity of the diffuser inlet section. The basic criteria for effective vane configurations with source-point translation were developed which indicated that the optimum pressure recovery was attained for both 30°and 40° diffusers at △θ=3°, the angle for measuring source-point translation. However the source-point translation did not bring any appreciable improvement in the performance for the 30° diffuser.
内容記述タイプ Other
内容記述 紀要論文
出版者
言語 ja
出版者 琉球大学理工学部
言語
言語 eng
資源タイプ
資源タイプ departmental bulletin paper
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
出版タイプ
出版タイプ VoR
出版タイプResource http://purl.org/coar/version/c_970fb48d4fbd8a85
識別子
識別子 http://hdl.handle.net/20.500.12000/24962
識別子タイプ HDL
収録物識別子
収録物識別子タイプ ISSN
収録物識別子 0387-429X
収録物識別子タイプ NCID
収録物識別子 AN00250785
収録物名
言語 ja
収録物名 琉球大学理工学部紀要. 工学篇
書誌情報
号 6, p. 39-50
戻る
0
views
See details
Views

Versions

Ver.1 2022-01-28 04:15:21.928171
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON

確認


Powered by WEKO3


Powered by WEKO3