{"_buckets": {"deposit": "734411da-72cc-4f57-b5fa-a220ee60a8c7"}, "_deposit": {"id": "2016011", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "2016011"}, "status": "published"}, "_oai": {"id": "oai:u-ryukyu.repo.nii.ac.jp:02016011", "sets": ["1642838207689", "1642838412624"]}, "author_link": [], "item_1617186331708": {"attribute_name": "Title", "attribute_value_mlt": [{"subitem_1551255647225": "[\u539f\u8457\uff3d\u5b50\u5bae\u9838\u764c\u9ad8\u7dda\u91cf\u7387\u8154\u5185\u7167\u5c04\u306b\u304a\u3051\u308bApplicator Type\u306e \u30a2\u30d7\u30ea\u30b1\u4e00\u5915\u914d\u7f6e\u306b\u53ca\u307c\u3059\u5f71\u97ff : ^\u003c192\u003eIr\u30b7\u30b9\u30c6\u30e0\u3068 ^\u003c60\u003eCo\u30b7\u30b9\u30c6\u30e0\u306e\u6bd4\u8f03\u7814\u7a76", "subitem_1551255648112": "ja"}, {"subitem_1551255647225": "A comparative study of the effectiveness of rigid and flexible applicators in the intracavitary radiotherapy with high dose rate for carcinoma of the uterine cervix", "subitem_1551255648112": "en"}]}, "item_1617186419668": {"attribute_name": "Creator", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "\u57a3\u82b1, \u6cf0\u653f", "creatorNameLang": "ja"}]}, {"creatorNames": [{"creatorName": "\u6238\u677f, \u5b5d\u6587", "creatorNameLang": "ja"}]}, {"creatorNames": [{"creatorName": "\u5c0f\u5ddd, \u548c\u5f66", "creatorNameLang": "ja"}]}, {"creatorNames": [{"creatorName": "\u4e2d\u91ce, \u653f\u96c4", "creatorNameLang": "ja"}]}, {"creatorNames": [{"creatorName": "Kakihana, Yasumasa", "creatorNameLang": "en"}]}, {"creatorNames": [{"creatorName": "Toita, Takafumi", "creatorNameLang": "en"}]}, {"creatorNames": [{"creatorName": "Ogawa, Kazuhiko", "creatorNameLang": "en"}]}, {"creatorNames": [{"creatorName": "Nakano, Masao", "creatorNameLang": "en"}]}]}, "item_1617186476635": {"attribute_name": "Access Rights", "attribute_value_mlt": [{"subitem_1522299639480": "open access", "subitem_1600958577026": "http://purl.org/coar/access_right/c_abf2"}]}, "item_1617186499011": {"attribute_name": "Rights", "attribute_value_mlt": [{"subitem_1522650717957": "ja", "subitem_1522651041219": "\u7409\u7403\u533b\u5b66\u4f1a"}]}, "item_1617186609386": {"attribute_name": "Subject", "attribute_value_mlt": [{"subitem_1522299896455": "en", "subitem_1522300014469": "Other", "subitem_1523261968819": "Intracavitary radiotherapy"}, {"subitem_1522299896455": "en", "subitem_1522300014469": "Other", "subitem_1523261968819": "uterine cervical cancer"}, {"subitem_1522299896455": "en", "subitem_1522300014469": "Other", "subitem_1523261968819": "^\u003c192\u003eIr and ^\u003c60\u003eCo HDR-RALS"}, {"subitem_1522299896455": "en", "subitem_1522300014469": "Other", "subitem_1523261968819": "applicator structure"}]}, "item_1617186626617": {"attribute_name": "Description", "attribute_value_mlt": [{"subitem_description": "The ^\u003c192\u003eIr system is replacing the ^\u003c60\u003eCo system in high dose rate remotely controlled afterloading system (HDR-RALS). One of the major differences between the two systems is the structure of the applicator. Flexible applicators are used in the ^\u003c60\u003eCo system but rigid ones in the ^\u003c192\u003eIr system. Although there are many reports on clinical and physical aspects of HDR-RALS, to our knowledge there is no report on the effect of the structure of the applicator. Our purpose is to study the effects of the structure of the applicator in relation to its arrangement in the treatment of carcinoma of the uterine cervix. Thirty-three patients with uterine cervical cancer treated with HDR-RALS were studied. Twenty-one cases were treated with the ^\u003c60\u003eCo system and 12 cases with the ^\u003c192\u003eIr system. Comparisons between ^\u003c60\u003eCo and ^\u003c192\u003eIr systems were made for 1) the slant angle of the tandem in anteroposterior and lateral planes, 2) the distance of left and right ovoids, 3) the ratio of left and right tandem-ovoid distance. The slant angle was -4\u00b0 for ^\u003c60\u003eCo and 23\u00b0 for ^\u003c192\u003eIr in the anteroposterio plane, and 8 for ^\u003c60\u003eCo and 3\u00b0 for ^\u003c192\u003eIr in the lateral plane. The separation of the ovoid was 2.7 cm for ^\u003c60\u003eCo and 2.5 cm for ^\u003c192\u003eIr. The ratio of the left tandem-ovoid distance to the right tandem-ovoid distance was 1.16 for ^\u003c60\u003eCo and 0.99 for ^\u003c192\u003eIr. Our results suggest the advantages of the rigid applicator in achieving better applicator arrangement than using the flexible applicator in the treatment of uterine cervical cancer.", "subitem_description_type": "Other"}, {"subitem_description": "\u8ad6\u6587", "subitem_description_type": "Other"}]}, "item_1617186643794": {"attribute_name": "Publisher", "attribute_value_mlt": [{"subitem_1522300295150": "ja", "subitem_1522300316516": "\u7409\u7403\u533b\u5b66\u4f1a"}, {"subitem_1522300295150": "en", "subitem_1522300316516": "Ryukyu Medical Association"}]}, "item_1617186702042": {"attribute_name": "Language", "attribute_value_mlt": [{"subitem_1551255818386": "jpn"}]}, "item_1617186920753": {"attribute_name": "Source Identifier", "attribute_value_mlt": [{"subitem_1522646500366": "ISSN", "subitem_1522646572813": "1346888X"}, {"subitem_1522646500366": "ISSN", "subitem_1522646572813": "0289-1530"}, {"subitem_1522646500366": "NCID", "subitem_1522646572813": "AN10369445"}]}, "item_1617186941041": {"attribute_name": "Source Title", "attribute_value_mlt": [{"subitem_1522650068558": "ja", "subitem_1522650091861": "\u7409\u7403\u533b\u5b66\u4f1a\u8a8c = Ryukyu Medical Journal"}]}, "item_1617187056579": {"attribute_name": "Bibliographic Information", "attribute_value_mlt": [{"bibliographicIssueNumber": "1", "bibliographicPageEnd": "35", "bibliographicPageStart": "33", "bibliographicVolumeNumber": "16"}]}, "item_1617258105262": {"attribute_name": "Resource Type", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_1617265215918": {"attribute_name": "Version Type", "attribute_value_mlt": [{"subitem_1522305645492": "VoR", "subitem_1600292170262": "http://purl.org/coar/version/c_970fb48d4fbd8a85"}]}, "item_1617605131499": {"attribute_name": "File", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_access", "download_preview_message": "", "file_order": 0, "filename": "v16p33.pdf", "future_date_message": "", "is_thumbnail": false, "mimetype": "", "size": 0, "url": {"objectType": "fulltext", "url": "https://u-ryukyu.repo.nii.ac.jp/record/2016011/files/v16p33.pdf"}, "version_id": "6c24df67-8fb1-4d23-b6b9-11c45e9462c7"}]}, "item_title": "[\u539f\u8457\uff3d\u5b50\u5bae\u9838\u764c\u9ad8\u7dda\u91cf\u7387\u8154\u5185\u7167\u5c04\u306b\u304a\u3051\u308bApplicator Type\u306e \u30a2\u30d7\u30ea\u30b1\u4e00\u5915\u914d\u7f6e\u306b\u53ca\u307c\u3059\u5f71\u97ff : ^\u003c192\u003eIr\u30b7\u30b9\u30c6\u30e0\u3068 ^\u003c60\u003eCo\u30b7\u30b9\u30c6\u30e0\u306e\u6bd4\u8f03\u7814\u7a76", "item_type_id": "15", "owner": "1", "path": ["1642838207689", "1642838412624"], "permalink_uri": "http://hdl.handle.net/20.500.12000/0002016011", "pubdate": {"attribute_name": "PubDate", "attribute_value": "2010-07-02"}, "publish_date": "2010-07-02", "publish_status": "0", "recid": "2016011", "relation": {}, "relation_version_is_last": true, "title": ["[\u539f\u8457\uff3d\u5b50\u5bae\u9838\u764c\u9ad8\u7dda\u91cf\u7387\u8154\u5185\u7167\u5c04\u306b\u304a\u3051\u308bApplicator Type\u306e \u30a2\u30d7\u30ea\u30b1\u4e00\u5915\u914d\u7f6e\u306b\u53ca\u307c\u3059\u5f71\u97ff : ^\u003c192\u003eIr\u30b7\u30b9\u30c6\u30e0\u3068 ^\u003c60\u003eCo\u30b7\u30b9\u30c6\u30e0\u306e\u6bd4\u8f03\u7814\u7a76"], "weko_shared_id": -1}
[原著]子宮頸癌高線量率腔内照射におけるApplicator Typeの アプリケ一夕配置に及ぼす影響 : ^<192>Irシステムと ^<60>Coシステムの比較研究
http://hdl.handle.net/20.500.12000/0002016011
http://hdl.handle.net/20.500.12000/0002016011