{"_buckets": {"deposit": "bc5c205c-7a67-443b-8562-0ff1f38bde6e"}, "_deposit": {"created_by": 8, "id": "2019671", "owner": "8", "owners": [8], "owners_ext": {"displayname": "ryukyu_lib", "username": null}, "pid": {"revision_id": 0, "type": "depid", "value": "2019671"}, "status": "published"}, "_oai": {"id": "oai:u-ryukyu.repo.nii.ac.jp:02019671", "sets": ["1642838338003", "1642838412624"]}, "author_link": [], "item_1617186331708": {"attribute_name": "Title", "attribute_value_mlt": [{"subitem_1551255647225": "Usefulness of INTELLiVENT-ASV for postoperative ventilator-associated pneumonia: a case report", "subitem_1551255648112": "en"}]}, "item_1617186419668": {"attribute_name": "Creator", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Taira, Takayuki", "creatorNameLang": "en"}]}, {"creatorNames": [{"creatorName": "Fuchigami, Tatsuya", "creatorNameLang": "en"}]}, {"creatorNames": [{"creatorName": "Hayashi, Misuzu", "creatorNameLang": "en"}]}, {"creatorNames": [{"creatorName": "Kamizato, Kouta", "creatorNameLang": "en"}]}, {"creatorNames": [{"creatorName": "Teruya, Kouji", "creatorNameLang": "en"}]}, {"creatorNames": [{"creatorName": "Kakinohana, Manabu", "creatorNameLang": "en"}]}]}, "item_1617186476635": {"attribute_name": "Access Rights", "attribute_value_mlt": [{"subitem_1522299639480": "open access", "subitem_1600958577026": "http://purl.org/coar/access_right/c_abf2"}]}, "item_1617186499011": {"attribute_name": "Rights", "attribute_value_mlt": [{"subitem_1522650717957": "en", "subitem_1522651041219": "© The Author(s). 2019"}, {"subitem_1522650717957": "en", "subitem_1522650727486": "http://creativecommons.org/licenses/by/4.0/", "subitem_1522651041219": "This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made."}]}, "item_1617186609386": {"attribute_name": "Subject", "attribute_value_mlt": [{"subitem_1522299896455": "en", "subitem_1522300014469": "Other", "subitem_1523261968819": "Artificial respiration"}, {"subitem_1522299896455": "en", "subitem_1522300014469": "Other", "subitem_1523261968819": "INTELLiVENT® iASV"}, {"subitem_1522299896455": "en", "subitem_1522300014469": "Other", "subitem_1523261968819": "Ventilator-associated pneumonia"}]}, "item_1617186626617": {"attribute_name": "Description", "attribute_value_mlt": [{"subitem_description": "Background: INTELLiVENT®-ASV (iASV) is a respiration mode on the Hamilton G5. The ventilator uses a closed-loop mechanism that automatically adjusts settings related to oxygenation and ventilation.\nCase presentation: A 47-year-old man underwent reconstruction surgery with free musculocutaneous flap for tongue resection. After surgery, the patient entered the ICU, and the iASV, which automatically changed only the percent minute volume (%MV) in respiration mode, was selected. On the second day, ventilator-associated pneumonia (VAP) was diagnosed, and the antibiotic treatment was changed. Using the settings of the iASV, automated FiO2 and positive end-expiratory pressure (PEEP) control were added to the ventilator mode. The patient’s oxygenation was improved.\nConclusions: In a patient who developed VAP after surgery, ventilation was continued using iASV, and automated changes in PEEP and FiO2 settings were successfully made according to the open lung strategy, under short-staffed circumstances.", "subitem_description_language": "en", "subitem_description_type": "Abstract"}]}, "item_1617186643794": {"attribute_name": "Publisher", "attribute_value_mlt": [{"subitem_1522300295150": "en", "subitem_1522300316516": "SpringerOpen"}]}, "item_1617186702042": {"attribute_name": "Language", "attribute_value_mlt": [{"subitem_1551255818386": "eng"}]}, "item_1617186941041": {"attribute_name": "Source Title", "attribute_value_mlt": [{"subitem_1522650068558": "en", "subitem_1522650091861": "JA Clinical Reports"}]}, "item_1617187056579": {"attribute_name": "Bibliographic Information", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2019-06-29", "bibliographicIssueDateType": "Issued"}}]}, "item_1617258105262": {"attribute_name": "Resource Type", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_1617265215918": {"attribute_name": "Version Type", "attribute_value_mlt": [{"subitem_1522305645492": "VoR", "subitem_1600292170262": "http://purl.org/coar/version/c_970fb48d4fbd8a85"}]}, "item_1617353299429": {"attribute_name": "Relation", "attribute_value_mlt": [{"subitem_1522306287251": {"subitem_1522306382014": "DOI", "subitem_1522306436033": "https://doi.org/10.1186/s40981-019-0262-x"}}]}, "item_1617605131499": {"attribute_name": "File", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_access", "date": [{"dateType": "Available", "dateValue": "2023-03-31"}], "download_preview_message": "", "file_order": 0, "filename": "s40981-019-0262-x.pdf", "filesize": [{"value": "555 KB"}], "future_date_message": "", "is_thumbnail": false, "mimetype": "", "size": 555000.0, "url": {"objectType": "fulltext", "url": "https://u-ryukyu.repo.nii.ac.jp/record/2019671/files/s40981-019-0262-x.pdf"}, "version_id": "be75969b-a6d9-4a6c-b761-2c23b729822b"}]}, "item_title": "Usefulness of INTELLiVENT-ASV for postoperative ventilator-associated pneumonia: a case report", "item_type_id": "59", "owner": "8", "path": ["1642838338003", "1642838412624"], "permalink_uri": "http://hdl.handle.net/20.500.12000/0002019671", "pubdate": {"attribute_name": "PubDate", "attribute_value": "2023-03-31"}, "publish_date": "2023-03-31", "publish_status": "0", "recid": "2019671", "relation": {}, "relation_version_is_last": true, "title": ["Usefulness of INTELLiVENT-ASV for postoperative ventilator-associated pneumonia: a case report"], "weko_shared_id": -1}
Usefulness of INTELLiVENT-ASV for postoperative ventilator-associated pneumonia: a case report
http://hdl.handle.net/20.500.12000/0002019671
http://hdl.handle.net/20.500.12000/0002019671