{"_buckets": {"deposit": "68e0c968-17bb-4628-9348-9be3f7517f6e"}, "_deposit": {"id": "2003838", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "2003838"}, "status": "published"}, "_oai": {"id": "oai:u-ryukyu.repo.nii.ac.jp:02003838", "sets": ["1642837863204", "1642838406845"]}, "author_link": [], "item_1617186331708": {"attribute_name": "Title", "attribute_value_mlt": [{"subitem_1551255647225": "Decentralised LQI-Type Load-frequency control with controlling delay of one sampling time for interconnected power systems", "subitem_1551255648112": "en"}]}, "item_1617186419668": {"attribute_name": "Creator", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Yamashita, Katsumi", "creatorNameLang": "en"}]}, {"creatorNames": [{"creatorName": "Miyagi, Hayao", "creatorNameLang": "en"}]}, {"creatorNames": [{"creatorName": "\u5c71\u4e0b, \u52dd\u5df1", "creatorNameLang": "ja"}]}, {"creatorNames": [{"creatorName": "\u5bae\u57ce, \u96bc\u592b", "creatorNameLang": "ja"}]}]}, "item_1617186476635": {"attribute_name": "Access Rights", "attribute_value_mlt": [{"subitem_1522299639480": "open access", "subitem_1600958577026": "http://purl.org/coar/access_right/c_abf2"}]}, "item_1617186626617": {"attribute_name": "Description", "attribute_value_mlt": [{"subitem_description": "This paper presents a new method of designing decentralised discrete-type load-frequency regulator with controlling delay of one sampling time for interconnected power systems. In this method, the interconnected multi-area electric energy system is decomposed into several subsystems, each of which is controlled separately by using a local feedback only. An especially attractive feature of the proposed control scheme is that it considers the time delay due to the computation time of the control law and the transmission time of the system data over the telemeter links to the controlling plant. An additional feature is that the construction of the regulator is based on the conventional tie-line bias control. The proposed control scheme is illustrated by digital simulation of a 2-area system provided with reheat steam turbines. The results show that this discrete-type regulator can act satisfactorily for improving dynamic responses of the load-frequency control.", "subitem_description_type": "Other"}, {"subitem_description": "\u7d00\u8981\u8ad6\u6587", "subitem_description_type": "Other"}]}, "item_1617186643794": {"attribute_name": "Publisher", "attribute_value_mlt": [{"subitem_1522300295150": "ja", "subitem_1522300316516": "\u7409\u7403\u5927\u5b66\u5de5\u5b66\u90e8"}]}, "item_1617186702042": {"attribute_name": "Language", "attribute_value_mlt": [{"subitem_1551255818386": "eng"}]}, "item_1617186783814": {"attribute_name": "Identifier", "attribute_value_mlt": [{"subitem_identifier_type": "HDL", "subitem_identifier_uri": "http://hdl.handle.net/20.500.12000/5572"}]}, "item_1617186920753": {"attribute_name": "Source Identifier", "attribute_value_mlt": [{"subitem_1522646500366": "ISSN", "subitem_1522646572813": "0389-102X"}, {"subitem_1522646500366": "NCID", "subitem_1522646572813": "AN0025048X"}]}, "item_1617186941041": {"attribute_name": "Source Title", "attribute_value_mlt": [{"subitem_1522650068558": "ja", "subitem_1522650091861": "\u7409\u7403\u5927\u5b66\u5de5\u5b66\u90e8\u7d00\u8981"}]}, "item_1617187056579": {"attribute_name": "Bibliographic Information", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "1988-03", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "35", "bibliographicPageEnd": "78", "bibliographicPageStart": "69"}]}, "item_1617258105262": {"attribute_name": "Resource Type", "attribute_value_mlt": [{"resourcetype": "departmental bulletin paper", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_1617265215918": {"attribute_name": "Version Type", "attribute_value_mlt": [{"subitem_1522305645492": "VoR", "subitem_1600292170262": "http://purl.org/coar/version/c_970fb48d4fbd8a85"}]}, "item_1617605131499": {"attribute_name": "File", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_access", "download_preview_message": "", "file_order": 0, "filename": "No35p69.pdf", "future_date_message": "", "is_thumbnail": false, "mimetype": "", "size": 0, "url": {"objectType": "fulltext", "url": "https://u-ryukyu.repo.nii.ac.jp/record/2003838/files/No35p69.pdf"}, "version_id": "914f7cdf-afdc-42b5-81b9-84e6125c7fc9"}]}, "item_title": "Decentralised LQI-Type Load-frequency control with controlling delay of one sampling time for interconnected power systems", "item_type_id": "15", "owner": "1", "path": ["1642837863204", "1642838406845"], "permalink_uri": "http://hdl.handle.net/20.500.12000/5572", "pubdate": {"attribute_name": "PubDate", "attribute_value": "2008-04-02"}, "publish_date": "2008-04-02", "publish_status": "0", "recid": "2003838", "relation": {}, "relation_version_is_last": true, "title": ["Decentralised LQI-Type Load-frequency control with controlling delay of one sampling time for interconnected power systems"], "weko_shared_id": -1}
  1. 紀要論文
  2. 琉球大学工学部紀要
  3. 35号
  1. 部局別インデックス
  2. 工学部

Decentralised LQI-Type Load-frequency control with controlling delay of one sampling time for interconnected power systems

http://hdl.handle.net/20.500.12000/5572
http://hdl.handle.net/20.500.12000/5572
6cd7e401-e328-4623-813f-4060c97e5e34
名前 / ファイル ライセンス アクション
No35p69.pdf No35p69.pdf
Item type デフォルトアイテムタイプ(フル)(1)
公開日 2008-04-02
タイトル
タイトル Decentralised LQI-Type Load-frequency control with controlling delay of one sampling time for interconnected power systems
言語 en
作成者 Yamashita, Katsumi

× Yamashita, Katsumi

en Yamashita, Katsumi

Miyagi, Hayao

× Miyagi, Hayao

en Miyagi, Hayao

山下, 勝己

× 山下, 勝己

ja 山下, 勝己

宮城, 隼夫

× 宮城, 隼夫

ja 宮城, 隼夫

アクセス権
アクセス権 open access
アクセス権URI http://purl.org/coar/access_right/c_abf2
内容記述
内容記述タイプ Other
内容記述 This paper presents a new method of designing decentralised discrete-type load-frequency regulator with controlling delay of one sampling time for interconnected power systems. In this method, the interconnected multi-area electric energy system is decomposed into several subsystems, each of which is controlled separately by using a local feedback only. An especially attractive feature of the proposed control scheme is that it considers the time delay due to the computation time of the control law and the transmission time of the system data over the telemeter links to the controlling plant. An additional feature is that the construction of the regulator is based on the conventional tie-line bias control. The proposed control scheme is illustrated by digital simulation of a 2-area system provided with reheat steam turbines. The results show that this discrete-type regulator can act satisfactorily for improving dynamic responses of the load-frequency control.
内容記述タイプ Other
内容記述 紀要論文
出版者
言語 ja
出版者 琉球大学工学部
言語
言語 eng
資源タイプ
資源タイプ departmental bulletin paper
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
出版タイプ
出版タイプ VoR
出版タイプResource http://purl.org/coar/version/c_970fb48d4fbd8a85
識別子
識別子 http://hdl.handle.net/20.500.12000/5572
識別子タイプ HDL
収録物識別子
収録物識別子タイプ ISSN
収録物識別子 0389-102X
収録物識別子タイプ NCID
収録物識別子 AN0025048X
収録物名
言語 ja
収録物名 琉球大学工学部紀要
書誌情報
号 35, p. 69-78, 発行日 1988-03